![Ude IPU-1025 Installation, Configuration And User Manual Download Page 5](http://html.mh-extra.com/html/ude/ipu-1025/ipu-1025_installation-configuration-and-user-manual_834185005.webp)
IPU-1025
OUT
IN
OK
DEVICE
CALL
FAULT
CONFIG NET
ACTIVITY
USB
ON
IPU-1025
Engineered and made in E.U.
1
4
6
5
7
3
2
8
4.- DESCRIPTION OF CONNECTIONS
29
5
4
3
2
1
5
LED ON
LED NET ACTIVITY
LED CONFIG
LED CALL IN
LED CALL OUT
1a
2a
3a
4a
. This indicator shows that the equipment is properly powered and that the main application is running.
. This indicator shows the data activity when is connected to an Ethernet LAN.
When you receive IP packets should be the LED blinking.
. This indicator shows that session of configuration (Setup) by Webserver is open.
. This indicator is set when an incoming call (active decoder mode) is received and accepted, and is active while the call emitter keep
the channel open. Once emitter point drop the call, the server of the installation disable the call and the CALL IN indicator will turn off.
When the LED remains off indicates that the IPU-1025 is not getting any calls.
. This indicator is activated when the IPU-1025 device is the generator of a voice call, there are two types of call:
Using a IP Paging Desk Controller (IPU-100P) connected to the IPU-1025 reports that the user is performing an outgoing call to one or more areas.
So that the LED is turned on the following sequence of events must happen.
.The IPU-100P device makes a request to the IPU-1025, to provide an outgoing call to one or more paging zones selected by touch
screen and Pressing the PTT button (talk).
.The IPU-1025 processes the request and sends the information through the IP network to the server to communicate with selected
decoders. The Call Out LED has not yet been activated, communication is not established.
.The IPU-360 processes and sends packets with information to the IPU-100 that communication begins feasible. At this time the CALL
OUT LED turns ON.
.This indication remains active until the user releases the call button. At which the IPU-1025 reports to the installation server the call
cancelling and when the cancellation is accepted, then the CALL OUT indication is turned off, releasing all resources used during
communication.
Encoding directly the audio signal connected to INPUT (+/-) of the IPU-1025, the device is able to detect the audio modulation and generate a call
to the extension that has been programmed on the Webserver. The IPU-360, Public Address IP manager, will determine the priority and connect
the call to the appropriate paging zones. Later will confirm the call to the IPU-1025, audio encoder, which turns on the CALL OUT LED.
While audio modulation was present or remote input was active, the IPU-1025 input will be encoded and sent through the IP network showing your
work status through the LED CALL OUT.
NOTE:This LED appears blinking (orange) while WEBSERVER session is open, although the operator / administrator has finished with
maintenance. It is desirable to close the work session when this is over to indicate properly the status and do not allow confusion with front
indicators.
IPU-100
IPU-100P
IPU-360
1a
2a
3a
4a
OUT
IN
OK
DEVICE
CALL
FAULT
CONFIG NET
ACTIVITY
USB
ON
Engineered and made in E.U.
IPU-100
IP
MESSAGE
SPEECH
USB
FAULT
ON
IPU-100P
4.1. Front view
610.440A
Installation - Configuration - Use - IPU-1025
Rev. 1