- 64 -
(the sensor accuracy is ±
1°C/2°F)).
Use the calibration feature to
match the indoor and outdoor
temperature to a known
source.
Indoor and Outdoor Humidity
do not agree
Allow up to one hour for the
sensors to stabilize due to
signal filtering. The indoor and
outdoor humidity sensors
should agree within 10 % (the
sensor accuracy is ± 5 %).
Use the calibration feature to
match the indoor and outdoor
humidity to a known source.
Display console contrast is
weak
Replace console batteries
with a fresh set of batteries.
13. Specification
13.1 Measurement Specifications
The following table provides specifications for the measured
parameters.
Measurement Range
Accuracy
Resolution
Indoor
Temperature
0 to 60 °C
(32 to 140°F)
± 1 °C
(± 2°F)
0.1 °C(°F)