49
50
7.3
|
TOO LONG FIBER
Error message generated when the fi ber is located too close to the electrodes, object lens or refl ector is dirty,
or the LED is not bright enough.
SOLUTION:
Press and reposition fi ber. Clean the object lens and refl ector. Conduct an LED test. If an error
occurs upon performing the LED test, contact UCLSWIFT.
7.4
|
FIBER OVER ANGLE
Error message generated when the cleaved angle of the fi ber is higher than specifi ed.
SOLUTION:
Check the state of the fi ber cleaver. Check the cleaved angle limit.
SWIFT KF4-EN, Rev.C 9
3.
Product Outline
3.1.
Function buttons
BUTTON
DESCRIPTION
Press and hold about 1 second to turn the power on/off.
Move the cursor to the left.
Move fiber to manual mode and adjust the camera’s focus.
Stripping popup menu should load.
Move the cursor to the right.
Move fiber to manual mode and adjust the camera’s focus.
Move the cursor upward.
Move each motor to manual mode.
Splice popup menu should load.
Move the cursor downward.
Move each motor to manual mode.
Heater popup menu should load.
Initialize the splice function.
Return to the menu screen.
Complete a selection.
Follow the next step on the menu screen.
Splice execution.
Return to the initial screen and initialize splice function.
Turn on the heater.
When it is on, the lamp on the left is in the red.
Press once more when it is on, and the heater is turned off.
SWIFT KF4-EN, Rev.C 66
7.3.
Too long fiber
Error message generated when the fiber is located too close to the electrodes, object lens or
reflector is dirty, or the LED is not bright enough.
Solution: Press
and reposition fiber. Clean the object lens and reflector. Conduct an LED test.
If an error occurs upon performing the LED test, contact UCLSWIFT.
7.4.
Fiber over angle
Error message generated when the cleaved angle of the fiber is higher than specified.
Solution: Check the state of the fiber cleaver. Check the cleaved angle limit.
SWIFT KF4-EN, Rev.C 66
7.3.
Too long fiber
Error message generated when the fiber is located too close to the electrodes, object lens or
reflector is dirty, or the LED is not bright enough.
Solution: Press
and reposition fiber. Clean the object lens and reflector. Conduct an LED test.
If an error occurs upon performing the LED test, contact UCLSWIFT.
7.4.
Fiber over angle
Error message generated when the cleaved angle of the fiber is higher than specified.
Solution: Check the state of the fiber cleaver. Check the cleaved angle limit.
7.5
|
LOSS LIMIT OVER
Error message generated when the estimated loss value is higher than the preset loss factor limit.
SOLUTION:
Check the loss factor limit.
7.6
|
FIBER THIN ERROR
Error message generated when the spliced point becomes thinner than the standard after splicing.
SOLUTION:
Make an adjustment to shorten the pulling length of the pulling splice. Check whether the arc
amount or arc time is set as too large or too long.
7.7
|
FIBER THICK ERROR
Error message generated when the spliced point becomes thicker than the standard after splicing.
SOLUTION:
Reduce the overlap set value. Check whether the arc amount or arc time is set as too small or
too short.
7.8
|
BUBBLE ERROR
Error message generated when there are bubbles or spots being generated on spliced point after splicing.
SOLUTION:
Examine the fi ber cleaver. Clean the V-groove. Examine the electrodes.
7.9
|
CLEAVED SURFACE ERROR
Error message generated when the cut surface of the fi ber is of poor quality.
SOLUTION:
Check the condition of the fi ber cleaver. Re-cleave the fi ber.
SWIFT KF4-EN, Rev.C 67
7.5.
Loss limit over
Error message generated when the estimated loss value is higher than the preset loss factor limit.
Solution: Check the loss factor limit.
7.6.
Fiber thin error
Error message generated when the spliced point becomes thinner than the standard after
splicing.
Solution: Make an adjustment to shorten the pulling length of the pulling splice. Check whether the
arc amount or arc time is set as too large or too long.
7.7.
Fiber thick error
Error message generated when the spliced point becomes thicker than the standard after
splicing.
Solution: Reduce the overlap set value. Check whether the arc amount or arc time is set as too
small or too short.
7.8.
Bubble error
Error message generated when there are bubbles or spots being generated on spliced point
after splicing.
Solution: Examine the fiber cleaver. Clean the V-groove. Examine the electrodes.
7.9.
Cleaved surface error
Error message generated when the cut surface of the fiber is of poor quality.
Solution: Check the condition of the fiber cleaver. Re-cleave the fiber.