![Ublox TOBY-L2 series System Integration Manual Download Page 40](http://html1.mh-extra.com/html/ublox/toby-l2-series/toby-l2-series_system-integration-manual_3394985040.webp)
TOBY-L2 and MPCI-L2 series - System Integration Manual
UBX-13004618 - R28
System description
Page 40 of 164
The USB profile of TOBY-L2 and MPCI-L2 modules identifies itself by its VID (Vendor ID) and PID
(Product ID) combination, included in the USB device descriptor according to the USB 2.0
specifications
The VID and PID of the default USB profile configuration with the set of functions described above (1
RNDIS for Ethernet-over-USB, and 1 CDC-ACM for AT commands and data) are the following:
VID = 0x1546
PID = 0x1146
summarizes the USB end-points available with the default USB profile configuration.
Default profile configuration
Interface 0
Wireless Controller – Remote NDIS
Interface 1
Communication Data
EndPoint
Transfer: Interrupt
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Interface 2 Communication Control – AT commands
EndPoint
Transfer: Interrupt
Interface 3
Communication Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function RNDIS
Function CDC Serial
Figure 19: TOBY-L2 and MPCI-L2 series USB End-Points summary for the default USB profile configuration
The USB of the modules can be configured by the AT+UUSBCONF command (for more details see the
u-blox AT Commands Manual
) to select different sets of USB functions available in mutually
exclusive way, selecting the active USB profile consisting of a specific set of functions with various
capabilities and purposes, such as:
CDC-ACM for AT commands and data
CDC-ACM for remote SIM Access Profile (SAP)
8
CDC-ACM for diagnostic
RNDIS for Ethernet-over-USB
CDC-ECM for Ethernet-over-USB
For example, the default USB profile configuration which provides 2 functions (1 RNDIS for
Ethernet-over-USB, and 1 CDC-ACM for AT commands and data) can be changed by means of the
AT+UUSBCONF command switching to a USB profile configuration which provides the following 6
functions:
3 CDC-ACM for AT commands and data
1 CDC-ACM for GNSS tunneling
9
1 CDC-ACM for remote SIM Access Profile (SAP)
10
1 CDC-ACM for diagnostic
8
Not supported by “00”, “01”, “02”, “60”, “62” product versions
9
Not supported by “00”, “01”, “02”, “03”, “60”, “62” product versions
10
Not supported by “00”, “01”, “02”, “60”, “62” product versions