SARA-N2 / N3 series - System integration manual
UBX-17005143 - R13
Product testing
Page 90 of 95
C1-Public
illustrates a typical test setup for such an RF functional test.
Application board
SARA-N2/N3
ANT
Application
processor
AT
commands
Cellular
antenna
Spectrum
analyzer
or
power
meter
IN
Wideband
antenna
TX
Application board
SARA-N2/N3
Application
processor
AT
commands
Signal
generator
OUT
Wideband
antenna
RX
ANT
Cellular
antenna
Figure 53: Setup with spectrum analyzer or power meter and signal generator for radiated measurements