Handling and soldering
Page 82 of 95
C1-Public
3.3.10
Casting
If casting is required, use viscose or another type of silicon pottant. The OEM is strongly advised to
qualify such processes in combination with the SARA-N2 / N3 series modules before implementing
this in the production.
☞
Casting will void the warranty.
3.3.11
Grounding metal covers
Attempts to improve grounding by soldering ground cables, wick or other forms of metal strips
directly onto the EMI covers is done at the customer's own risk. The numerous ground pins should be
sufficient to provide optimum immunity to interferences and noise.
☞
u-blox gives no warranty for damages to the SARA-N2 / N3 series modules caused by soldering
metal cables or any other forms of metal strips directly onto the EMI covers.
3.3.12
Use of ultrasonic processes
SARA-N2 / N3 series modules contain components which are sensitive to Ultrasonic Waves. Use of
any Ultrasonic Processes (cleaning, welding etc.) may cause damage to the module.
☞
u-blox gives no warranty against damages to the SARA-N2 / N3 series modules caused by any
ultrasonic processes.