![Ubisys H1 Manual Download Page 25](http://html1.mh-extra.com/html/ubisys/h1/h1_manual_3147076025.webp)
25
Heating Control H1
Chapter 4
| Schedules
1x + 1x
17:00
17:15
17°C
17:00
22:00
22°C
06:00
09:00
22°C
09:00
09:15
22°C
MON-SUN
6-9::22.0°C
9-17::17.0°C
MON-FRI,
SAT-SUN
MON, TUE,
WED, THU, FRI,
SAT, SUN
MON
0
6
12
18
24
MON
0
6
12
18
24
MON
0
6
12
18
24
00:00
00:00
7.0°C
1
06:00
09:00
22.0°C
1
09:00
09:15
22.0°C
2
1
09:00
17:00
17.0°C
2
1
06:00
09:00
22.0°C
3
2
06:00
09:00
22.0°C
3
2
1
1
06:00
09:00
22.0°C
3
2
1
3. Select the day(s) of the week you want to change by turning the
dial and press the button to confirm (e.g. MON-SUN = Monday to
Sunday).
1x + 1x
17:00
17:15
17°C
17:00
22:00
22°C
06:00
09:00
22°C
09:00
09:15
22°C
MON-SUN
6-9::22.0°C
9-17::17.0°C
MON-FRI,
SAT-SUN
MON, TUE,
WED, THU, FRI,
SAT, SUN
MON
0
6
12
18
24
MON
0
6
12
18
24
MON
0
6
12
18
24
00:00
00:00
7.0°C
1
06:00
09:00
22.0°C
1
09:00
09:15
22.0°C
2
1
09:00
17:00
17.0°C
2
1
06:00
09:00
22.0°C
3
2
06:00
09:00
22.0°C
3
2
1
1
06:00
09:00
22.0°C
3
2
1
4. In the left column you can see the number (
1-3
) of your created
slots with a dark
1
. If you want to edit/delete your first slot, press
the button.
By turning the rotary dial you can switch to another slot. To edit,
press the button.
Or use the rotary dial to switch to the following options (selected =
dark background) and then also confirm by pressing the button:
(
)
: Add slot
( ): Cancel
( ): All slots (1-3) will be deleted
1x + 1x
17:00
17:15
17°C
17:00
22:00
22°C
06:00
09:00
22°C
09:00
09:15
22°C
MON-SUN
6-9::22.0°C
9-17::17.0°C
MON-FRI,
SAT-SUN
MON, TUE,
WED, THU, FRI,
SAT, SUN
MON
0
6
12
18
24
MON
0
6
12
18
24
MON
0
6
12
18
24
00:00
00:00
7.0°C
1
06:00
09:00
22.0°C
1
09:00
09:15
22.0°C
2
1
09:00
17:00
17.0°C
2
1
06:00
09:00
22.0°C
3
2
06:00
09:00
22.0°C
3
2
1
1
06:00
09:00
22.0°C
3
2
1
5. If you have selected a slot by pressing the button (selected = dark
background) to change it, follow the points 5-7 from the section
„
Create schedule
“.
Other options that you can select by turning the dial and then con-
firm with the button can be found in the right column:
Save and quit
( ): Changes are saved.
Cancel
( ): Process will be canceled. If you have made new set-
tings, these will be revoked.
Delete
( ): The currently selected time slot will be deleted.
Note:
To be able to select the options in the right column, you
must have confirmed start time ( ), stopp time ( ) and target
temperature ( ) by button.
Summary of Contents for H1
Page 1: ...Heating Control H1 Manual...
Page 4: ...4 Heating Control H1 Chapter 1 General...
Page 8: ...8 Heating Control H1 Chapter 2 Commissioning...
Page 15: ...15 Heating Control H1 Chapter 3 Set Room Temperature...
Page 20: ...20 Heating Control H1 Chapter 4 Schedules...
Page 29: ...29 Heating Control H1 Chapter 5 More Functions and Information...