27
www.ubisys.de
7.5.2.2.
Set Configuration
Set a configuration option. Please not that only the current configuration is updated. The configuration
must be explicitly saved to non-volatile memory to be preserved permanently. Otherwise, the previously
saved configuration will be restored on the next system startup.
Request
CLA
INS
P1
P2
Lc
Le
FFh
33h
01h
Configuration item
Length of the value to set
Value to set
ignored
Response
SW1
SW2
Response codes
SW1
SW1
Meaning
90h
00h
Configuration updated.
67h
00h
Wrong length.
6Ah
81h
Function not supported. The specified parameter value is invalid
6Bh
00h
Unsupported parameter P1-P2 combination.
7.5.2.3.
Save Configuration
Save the configuration to non-volatile memory. The current configuration will be preserved and
reloaded on the next system start-up.
Request
CLA
INS
P1
P2
Le
FFh
33h
80h
43h
ignored
Response
SW1
SW2
Response codes
SW1
SW1
Meaning
90h
00h
Command executed successfully. The configuration was saved.
64h
00h
Failed to save configuration to non-volatile memory.