Pressure Logger Operation

Contents:

Product Applications and Useful Features
Product Specifications
Operating Instructions / Getting Started
DicksonWare Software Specifications
Product Accessories
Calibrations
Troubleshooting & Battery
Warranty / Factory Service & Returns

A

pp

lic

at

io

ns

U

se

fu

l F

ea

tu

re

s,

& S
pe

cifi

ca

tio

ns

D

IC

K

SO

N

O

pe

ra

tin

In

st

ru

ct

io

ns / 

G

et

tin

g S
ta

rt

ed

So

ft

w

ar

e

Sp

ec

ifi

ca

tio

ns

A

cc

es

so

rie

s & 

C

ali

br

at

io

ns

Tr

ou

ble

sh

oo

tin

& W

ar

ra

nt

y/ 

R

et

ur

ns

Summary of Contents for PR125

Page 1: ...perating Instructions Getting Started DicksonWare Software Specifications Product Accessories Calibrations Troubleshooting Battery Warranty Factory Service Returns Applications Useful Features Specifications DICKSON Operating Instructions Getting Started Software Specifications Accessories Calibrations Troubleshooting Warranty Returns ...

Page 2: ...A x 7 11 cm H Weight 10 7 oz 300 7 g Minimum Version Dicksonware Required 12 4 Applications Useful Features Specifications DICKSON Product Applications One step data retrieval for utility operators on the go retrive data without the bother of moving data loggers or laptops Easy to See Easy to Download Data User friendly DicksonWare software makes it simple to integrate recorded pressure data into ...

Page 3: ...y stored Your logger is now ready to be placed in the desired logger location Changing Logger Defaults Pressure Logger Defaults Sample Rate 5 Minues Stop or Wrap When Full Wrap Logger Display Unit of Measure PSI DicksonWare Unit of Measure PSI To change any of the logger defaults connect the logger to your PC via the USB cable and open DicksonWare Click on Setup The following settings can be modif...

Page 4: ...le Shooting section at www DicksonData com MIN MAX Pressing this button will start the Min Max display cycle Clearing MIN MAX Values Holding the MIN MAX button down for 3 seconds until clr appears on display will clear the stored minimum and maximum values The Min and Max displayed by the logger will be the minimum and maximum values sensed since it was last cleared Note DicksonWare will show the ...

Page 5: ...asy set up of Dickson Data Loggers including User selectable sample intervals from 10 seconds to 24 hours Display temperature in C or F Delayed logger start times Logger data capacity can be set to wrap data or stop when full Allow for real time monitoring and graphing Effortless exporting of data and graphs to other software Data can be viewed in tabular numeric table or graphical formats Fast do...

Page 6: ...cted points of as found data before and after calibration for Dickson temperature and or humidity instrumentation N995 NIST User Selected Temperature Points Documentation of one customer specified point Should be selected in addition to one of the above calibration options Why should I recalibrate my instrumentation Over time dirt dust and normal handling can throw your precision instrumentation o...

Page 7: ...kson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products Customer Satisfaction Dickson takes pride in providing you the customer with the highest quality instrumentation We welcome the opportunity to help you in any way possible Whether it be a question or a new idea in documentation the Dickson Company would like to hear your response ...

Reviews: