background image

3. The System LED on the UniFi Switch will turn blue to con rm that it has been successfully

adopted.

Speci cations

USW-16-POE

Dimensions

424.4 x 200 x 43.7 mm

(16.71 x 7.87 x 1.72")

Weight

2.80 kg (6.17 lb)

With Rackmount Brackets

2.89 kg (6.37 lb)

Interfaces

Networking

(16) 10/100/1000 RJ45 Ports 

(2) 1G SFP Ethernet Ports

Management

Ethernet In-Band

Power Method

100-240VAC/50-60 Hz, Universal Input

Power Supply

AC/DC, Internal, 60W

Supported Voltage Range

100 to 240VAC

Max. Power Consumption

(Excluding PoE Output)

18W

LEDs

System

Status

RJ45 Data Ports

PoE; Speed/Link/Activity

SFP Data Ports

Link/Activity

ESD/EMP Protection

Air: ± 16 kV, Contact: ± 12 kV

Shock and Vibration

ETSI300-019-1.4 Standard

Operating Temperature

-5 to 40° C (23 to 104° F)

Operating Humidity

10 to 90% Noncondensing

USW-16-POE Quick Start Guide

Summary of Contents for UniFi USW-16-POE

Page 1: ...Java Runtime Environment 1 6 1 8 or newer recommended Web Browser Google Chrome Other browsers may have limited functionality UniFi Controller software v5 11 x or newer available at ui com download uni IMPORTANT We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power Hardware Overview USW 16 POE Quick Start Guide ...

Page 2: ...essfully adopted by a network and working properly Location Animation This indicates that you clicked Locate in the UniFi Controller software The software will also display the location of the device on the map Off No PoE Amber 802 3af at PoE Off No Link Amber Link Established at 10 100 Mbps Flashing Indicates Activity Green Link Established at 1000 Mbps Flashing Indicates Activity Off No Link USW 16...

Page 3: ...port Installation Requirements Phillips screwdriver Standard sized 19 wide rack with a minimum of 1U height available For indoor applications use Category 5 or above UTP cabling approved for indoor use For outdoor applications shielded Category 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply We recommend that you...

Page 4: ...2 OR USW 16 POE Quick Start Guide ...

Page 5: ...Connecting Power 1 USW 16 POE Quick Start Guide ...

Page 6: ...2 Connecting Ethernet USW 16 POE Quick Start Guide ...

Page 7: ...Note If you are connecting PoE devices check the display to see how much PoE wattage is available Connecting SFP 1 2 USW 16 POE Quick Start Guide ...

Page 8: ...oftware at ui com download uni and follow the on screen instructions Note If you already have UniFi Controller v5 11 x or newer installed skip to Adopting the UniFi Switch After you have installed the software and run the UniFi Installation Wizard a login screen will appear for the UniFi Controller management interface Enter the admin name and password USW 16 POE Quick Start Guide ...

Page 9: ... Switch For information on con guring and using the UniFi Controller software refer to the User Guide on the website ui com download uni Adopting the UniFi Switch 1 From the UniFi Controller dashboard click Devices in the left menu bar 2 On the Devices screen locate the UniFi Switch in the list of devices under the Model column To adopt the UniFi Switch click Adopt USW 16 POE Quick Start Guide ...

Page 10: ...Ethernet Ports Management Ethernet In Band Power Method 100 240VAC 50 60 Hz Universal Input Power Supply AC DC Internal 60W Supported Voltage Range 100 to 240VAC Max Power Consumption Excluding PoE Output 18W LEDs System Status RJ45 Data Ports PoE Speed Link Activity SFP Data Ports Link Activity ESD EMP Protection Air 16 kV Contact 12 kV Shock and Vibration ETSI300 019 1 4 Standard Operating Tempe...

Page 11: ...er s label Connection to a different power source than those speci ed may result in improper operation damage to the equipment or pose a re hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a quali ed service technician 3 This equipment is provided with a detachable power cord which has an integral safety gr...

Page 12: ...ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference ...

Page 13: ...Online Resources 2019 Ubiquiti Inc All rights reserved USW 16 POE Quick Start Guide ...

Reviews: