background image

6

© 2021 Ubicquia Inc.  |  All rights reserved. Patent pending. Public use approved.  |  2058 v2 October 2021

6.3

   Line up the NEMA plug on the 

UbiHub with the NEMA socket 

on the luminaire. The UbiHub 

should be slightly off-angle of 

the luminaire by 15 degrees once 

inserted. 

NOTE:

 Make sure the NEMA 

plug and NEMA socket remain 

parallel during installation.

NOTE: CREE fixtures/NEMA will 

need to be locked in

6.4

   Once plugged, rotate the UbiHub 

towards the pole to lock the NEMA 

connecter in place. Stop once the 

clamp is aligned with the pole.

6.6

   Adjust the clamp vertically as 

necessary to ensure the device 

is parallel with the bottom of the 

luminaire to ensure there is no 

undue stress or strain on the NEMA 

socket.

6.5

   Close the clamp around the 

pole by rotating the clamp latch 

upwards and securing with the 

swivel locking nut. Use 1/2” 

socket to tighten the locking nut 

to 40 in-lbs torque.

B.

Pull the inside (grey) section of

the NEMA connector out slightly

and twist until the N > is facing in

the correct direction (away from the

luminaire pole).

A.

Use a screwdriver to remove the

two screws. Unscrew the NEMA

connector and lift then turn the

NEMA connector until the N > is

facing in the correct direction (away

from the luminaire pole).

Summary of Contents for UBH-H-AI

Page 1: ...ding Public use approved 2058 v2 October 2021 Installation Guide 1 Product Overview 1 1 View of UbiHub parts from top Before installation please read this instructional guide completely and save for future reference 1 2 View of UbiHub parts from bottom ...

Page 2: ... all items listed in the package contents ref 1 2 are included in the box If any item is missing e mail support ubicquia com or call 1 954 678 6191 Monday through Friday 9am to 5pm EST 2 3 Remove the mounting clamp from foam insert and unwrap the protective film Caution DO NOT remove the UbiHub from the box yet 3 Preinstall Clamp 3 2 Mounting Clamp The mounting clamp has inserts available to fit 1...

Page 3: ...ide the clamp along the housing rails and hand tighten into position for now NOTE If clamp placement was premeasured or if installing multiple units on the same luminaire type set the clamp position using the reference dimensions on both the housing and clamp then tighten all adjustment bolts to 40 in lbs torque 3 3 OPTIONAL Measure the distance from the NEMA socket to the closest point on the pol...

Page 4: ...ottom clamp insert The inserts should be placed into the corresponding location in the clamp ensuring a complete fit They should not be loose after install Move on when the clamp inserts are firmly in place 4 1 Attach the provided grounding cable to the UbiHub housing using the grounding screw with a standard screwdriver or 5 16 socket Note the location for the safety tether attachment WARNING Ubi...

Page 5: ...ed to the unit by a cable Caution Take care not to swing slam or knock the camera during installation The camera should be placed atop the unit during install whenever possible Make sure clamp is open with the swivel locking nut up out of the way before installing on the luminaire 5 3 Attach a safety tether to both UbiHub and the lift using the tether ring on the UbiHub If your luminaire has a pho...

Page 6: ...gned with the pole 6 6 Adjust the clamp vertically as necessary to ensure the device is parallel with the bottom of the luminaire to ensure there is no undue stress or strain on the NEMA socket 6 5 Close the clamp around the pole by rotating the clamp latch upwards and securing with the swivel locking nut Use 1 2 socket to tighten the locking nut to 40 in lbs torque B Pull the inside grey section ...

Page 7: ...ed grounded and secured firmly in place before moving on 7 Grounding Cable Installation 6 8 Remove tether from unit NOTE Remove all protective packaging material from the camera prior to installation 6 10 Tighten the camera top screw to 15 in lbs torque using the 3 16 Hex bit driver CAUTION The unit must be grounded in accordance with the local codes or regulations defined by the local inspector T...

Page 8: ...op light sensor 8 Installing Photocell Optional 8 3 Installation of the UbiHub is now complete Make sure UbiHub and all elements are connected and secured firmly in place 8 2 Insert the photocell into the NEMA connector on the top of the UbiHub and twist clockwise until locked in place CAUTION The UbiHub does not need a photocell to function but should always have something installed in the NEMA N...

Page 9: ...pment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may...

Page 10: ...d For example safety gloves device tether warning labels flash lamp helmet and or work clothes etc In the process of installation please ensure the weather is suitable for outdoor high power electrical work If possible the installer should avoid installing in the rain or allowing the NEMA to get wet WARNING The product is required to be installed and to be connected to mains power by a skilled or ...