3
© 2021 Ubicquia Inc. | All rights reserved. Patent pending. Public use approved. | 2058 v2 October 2021
3.4
Use a 3/16” Hex bit driver to
unscrew and remove the clamp
adjustment cover from the clamp.
Discard as this piece is no longer
needed.
3.5
Align the shuttles on the top of the
clamp with the rail openings on
the bottom of the UbiHub housing
while still in the box. There is a
single orientation for assembly.
3.6
Slide the clamp along the housing
rails and hand-tighten into position
for now.
NOTE:
If clamp placement was
premeasured, or if installing
multiple units on the same
luminaire type, set the clamp
position using the reference
dimensions on both the housing
and clamp, then tighten all
adjustment bolts to 40 in-lbs
torque.
3.3
OPTIONAL:
Measure the distance
from the NEMA socket to the
closest point on the pole that will
allow for the Ubihub to be seated
level to the luminaire.
NOTE:
Record position
horizontal and vertical
dimensions on UbiHub and
clamp for later use in multiple
installations of the same
luminaire type.