background image

Installation and putting into operation 

13 

printed: 02/2015  Subject to change! 

 

 TopLineUserManualKT.docx 

4  Installation and putting into operation 

In general all Cold Display Cabinets will be packed for safe transport after the final 

control in order to reach you properly. Nevertheless we ask you to have a look at the 

machine on arrival to detect any transport damages if there are any. 

Note! 

Visible damages have to be reported immediately! 

 

4.1  Unwrapping 

  Open the carton and take out the wrapping material carefully. 

  Take care that the delivery is complete (see attached freight papers). 

4.2  Installation 

Place the cabinet in the desired location. Make sure, that is is good visible for your 

customer to ensure good foodpresentation and successfull sales. 

Take care of the following points: 

  Place the Cabinet dry. 

  Take care that the Cabinet has to be placed in well ventilated rooms! Mounted in 

a  cut  out  of  a  counter  with  air  openings  (min.  air  inlet  opening  of  419,1mm  by 

215,9mm  and  discharge  opening  of  482,6  by  228,6mm).  Fitted  with  silicon  all 

around the cabinet. 

  Avoid  to  place  the  cabinet  close  to  any  heat-sources  (heaters,  radiators,  sun-

beams and the like). 

  The cooling compartment (condenser and compressor) below the cabinet must be 

well ventilated after installation. 

  The cabinet (with or without stand) has to be placed on a horizontal level. Use a 

spirit level if necessary.  

  Take care that both sides have at least 10cm clear space to enable cleaning of 

the sideglasses. 

  There has to be enough free space to load, unload, clean and maintain the unit. 

  The machine has to be placed so that the complete area around it can be cleaned 

easily. 

 

4.3  Electrical connection 

Note!

  In  general,  only  service  technicians  of  the  company:  UBERT  GASTRO-

TECHNIK  GMBH  or  service  technicians  of  your  responsible  service  partner  are  al-

lowed  to  perform  el.  connection  and  other  service!  All  national  and  lokal  rules  and 

regulations  concerning  electricity, fireprotection and  the  like  have to be  concidered. 

During any servicing, take care that the unit is disconnected from the mains! Not pay-

ing attention may result in injury! 

 

Please learn the electrical and technical data of your unit from the nameplate. 

  Check whether your lokal electrical power supply is in accordance with the values on the name 

plate. 

  The power supply needs to be manufactured from heat resistant, flexible cable. It is to be routed 

to prevent any contact to hot parts. 

  The unit is to be connected to the power supply either by means of an appropriate plug or if con-

nected permanently, a switch (interupting all poles) is to be provided. In case of an emergancy 

the power supply must be interuptable immediately. 

  For further information please see the wiring diagram (below). 

Note!

 

After finishing any installationwork, maintainance or repair check whether the ground 

wires are connected properly to the casing. 

 

Summary of Contents for KT 700

Page 1: ...User Manual COLD DISPLAY CABINET KT Series...

Page 2: ......

Page 3: ...1 Introduction 8 3 2 Special features 8 3 3 Technical details 9 4 Installation and putting into operation 13 4 1 Unwrapping 13 4 2 Installation 13 4 3 Electrical connection 13 4 4 Preparation of Usin...

Page 4: ...ined regularly 2 1 3 Obligation of the personnel All induviduals who are authorized to work with the unit are obliged to pay attention to the fundamental regulations of work safety and accident avoidi...

Page 5: ...e of wear and tear parts Unauthorized repair Force of nature and act of god 2 3 Symbols and Notes In the operating manual the following symbols and signs are used This symbol means a possibly or direc...

Page 6: ...personal are to be determined clearly for installing start up operation assembling and servicing of the unit During instruction the personal may only work at the unit under supervision of an experienc...

Page 7: ...nintended reclos ing Check all screw connections for tight fitting After finishing maintenance check all safety devices for proper functionality 2 5 9 Structural changes to the unit Do not perform any...

Page 8: ...utes The Cold Display Cabinets show a high cooling performance Within the Cold Display Cabinets the cooling convection pro vides a stable temperature The set tempera tures are reached within one hour...

Page 9: ...Introduction 9 printed 02 2015 Subject to change TopLineUserManualKT docx 3 3 Technical details 3 3 1 Dimensions mm KT 700 KT 700 DB...

Page 10: ...10 Introduction printed 02 2015 Subject to change TopLineUserManualKT docx KT 1100 KT 1100 DB...

Page 11: ...Introduction 11 printed 02 2015 Subject to change TopLineUserManualKT docx KT 1400 KT 1400 DB...

Page 12: ...50Hz 0 42 kW KT 1400 230V 1 N 50Hz 0 44 kW KT 700 DB 230V 1 N 50Hz 0 33 kW KT 1100 DB 230V 1 N 50Hz 0 45 kW KT 1400 DB 230V 1 N 50Hz 0 47 kW KT 700 2 120V 1 N 50Hz 0 21 kW KT 1100 2 120V 1 N 50Hz 0 33...

Page 13: ...horizontal level Use a spirit level if necessary Take care that both sides have at least 10cm clear space to enable cleaning of the sideglasses There has to be enough free space to load unload clean...

Page 14: ...on wait at least 30 minutes before restart Before operating the Cold Display Cabinet you have to clean the unit and all removable parts e g GN basins carefully with a grease solvent Afterwards you hav...

Page 15: ...well as temperature control is located un derneath the stainless steel cover 5 2 Operate Switch Fan This switch activates the fan which responsible for convection The fan is activated when the light...

Page 16: ...ermediate Shelf The Intermediate Shelf is located above the GN pans for additional storage space Timer only UL version The timer is left next to the switches for the illumination and the fan The cycle...

Page 17: ...fterwards so that there are no residues of the cleaner on these parts It is absolutely necessary to watch out for some fundamental things to keep this longliving high grade steel machine working alway...

Page 18: ...soft cloth to avoid scratches Drawers GN Pans Easily removable without tools for separate cleaning Air openings evaporator All air openings as well as the evaporator need to be cleaned regularly to en...

Page 19: ...work and replacement of defect parts If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid Checklist for your Cold Display Cabinet 1...

Page 20: ...20 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 Wiring Diagrams 6 3 1 KT 700 230V 50Hz 1 N 6 3 2 KT 700 DB 230V 50Hz 1 N...

Page 21: ...Maintenance 21 printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 3 KT 1100 230V 50Hz 1 N 6 3 4 KT 1100 DB 230V 50Hz 1 N...

Page 22: ...22 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 5 KT 1400 230V 50Hz 1 N 6 3 6 KT 1400 DB 230V 50Hz 1 N...

Page 23: ...Maintenance 23 printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 7 KT 700 2 UL 120V 50Hz 1 N 6 3 8 KT 700 2 DB UL 120V 50Hz 1 N...

Page 24: ...24 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 9 KT 1100 2 UL 120V 50Hz 1 N 6 3 10 KT 1100 2 DB UL 120V 50Hz 1 N...

Page 25: ...Maintenance 25 printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 11 KT 1400 2 UL 120V 50Hz 1 N 6 3 12 KT 1400 2 DB UL 120V 50Hz 1 N...

Page 26: ...ed out only by their service personal or by your authorized Service companies If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid A...

Page 27: ...ing unit KT 700 KT 700 DB 346104 1 17 cooling unit KT 700 2 KT 700 2DB 346115 1 18 thermometer 40 C to 40 C KT 700 KT 700 DB 342908 1 18 thermometer 40 F to 100 F KT 700 2 KT 700 2DB 342911 1 19 tumbe...

Page 28: ...ast KT 1100 2DB 340633 1 17 cooling unit KT 1100 KT 1100 DB 346105 1 17 cooling unit KT 1100 2 KT 1100 2DB 346116 1 18 thermometer 40 C to 40 C KT 1100 KT 1100 DB 342908 1 18 thermometer 40 F to 100 F...

Page 29: ...t KT 1400 KT 1400 DB 346106 1 17 cooling unit KT 1400 2 KT 1400 2DB 346116 1 18 thermometer 40 C to 40 C KT 1400 KT 1400 DB 342908 1 18 thermometer 40 F to 100 F KT 1400 2 KT 1400 2DB 342911 1 19 tumb...

Page 30: ...30 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 5 Declaratoin Of Conformity...

Reviews: