Ubert KT 700 User Manual Download Page 6

Important References 

printed: 02/2015  Subject to change! 

 

 TopLineUserManualKT.docx 

2.5  Special safety references 

 

2.5.1  Safety devices 

  Before operating the unit all protective devices as well as all removable parts must 

be installed correctly and be fully workable. 

  Protective devices may only be removed: 

  after stand still and 

  prevention of unintentional restart. 

  If partial components are delivered, an authorized staff member or service tech-

nician has to execute assembly according to installation guidelines. 

2.5.2  Informal safety steps 

  The operating manual is to be kept constantly accessible in the operating area. 

  In addition to the operating manual all generally acknowledged and all local regula-

tions for accident avoiding and environmental protection have to be applied with. 

  All safety- danger labels at the unit are to be kept in readable condition. 

2.5.3  Education of the personal 

  Only trained and instructed personal may work at the unit. 

  The responsibilities of the personal are to be determined clearly for installing, start-

up, operation, assembling, and servicing of the unit. 

  During  instruction  the  personal  may  only  work  at  the  unit  under  supervision  of  an 

experienced person. 

2.5.4  Unit-control 

  Only instructed personal is allowed to operate the controls. 

2.5.5  Safety during regular operation 

  The unit is only to operate if all protective devices are fully workable. 

  At least once per shift the unit is to be examined with regard to visible damages and 

functional ability of the safety devices. 

2.5.6  Dangers caused by electric energy 

  Any work on the electrical supply is to be executed only by a specialist. 

  Likewise the electrical connection of this unit to the power supply must be executed 

by an electro-specialist; the connection must follow the rules of the local determina-

tions. 

  The electric installation is to be examined regularely. Loose connections and brased 

cabels are to be eliminated immediately. 

  If works at any life-parts are necessary, a second person who switches off the main 

switch if neccessary is to consult. 

2.5.7  Special danger-spots 

  Do not touch the cooling plant if the unit is switched on! 

  Do not touch the evaporator! 

Summary of Contents for KT 700

Page 1: ...User Manual COLD DISPLAY CABINET KT Series...

Page 2: ......

Page 3: ...1 Introduction 8 3 2 Special features 8 3 3 Technical details 9 4 Installation and putting into operation 13 4 1 Unwrapping 13 4 2 Installation 13 4 3 Electrical connection 13 4 4 Preparation of Usin...

Page 4: ...ined regularly 2 1 3 Obligation of the personnel All induviduals who are authorized to work with the unit are obliged to pay attention to the fundamental regulations of work safety and accident avoidi...

Page 5: ...e of wear and tear parts Unauthorized repair Force of nature and act of god 2 3 Symbols and Notes In the operating manual the following symbols and signs are used This symbol means a possibly or direc...

Page 6: ...personal are to be determined clearly for installing start up operation assembling and servicing of the unit During instruction the personal may only work at the unit under supervision of an experienc...

Page 7: ...nintended reclos ing Check all screw connections for tight fitting After finishing maintenance check all safety devices for proper functionality 2 5 9 Structural changes to the unit Do not perform any...

Page 8: ...utes The Cold Display Cabinets show a high cooling performance Within the Cold Display Cabinets the cooling convection pro vides a stable temperature The set tempera tures are reached within one hour...

Page 9: ...Introduction 9 printed 02 2015 Subject to change TopLineUserManualKT docx 3 3 Technical details 3 3 1 Dimensions mm KT 700 KT 700 DB...

Page 10: ...10 Introduction printed 02 2015 Subject to change TopLineUserManualKT docx KT 1100 KT 1100 DB...

Page 11: ...Introduction 11 printed 02 2015 Subject to change TopLineUserManualKT docx KT 1400 KT 1400 DB...

Page 12: ...50Hz 0 42 kW KT 1400 230V 1 N 50Hz 0 44 kW KT 700 DB 230V 1 N 50Hz 0 33 kW KT 1100 DB 230V 1 N 50Hz 0 45 kW KT 1400 DB 230V 1 N 50Hz 0 47 kW KT 700 2 120V 1 N 50Hz 0 21 kW KT 1100 2 120V 1 N 50Hz 0 33...

Page 13: ...horizontal level Use a spirit level if necessary Take care that both sides have at least 10cm clear space to enable cleaning of the sideglasses There has to be enough free space to load unload clean...

Page 14: ...on wait at least 30 minutes before restart Before operating the Cold Display Cabinet you have to clean the unit and all removable parts e g GN basins carefully with a grease solvent Afterwards you hav...

Page 15: ...well as temperature control is located un derneath the stainless steel cover 5 2 Operate Switch Fan This switch activates the fan which responsible for convection The fan is activated when the light...

Page 16: ...ermediate Shelf The Intermediate Shelf is located above the GN pans for additional storage space Timer only UL version The timer is left next to the switches for the illumination and the fan The cycle...

Page 17: ...fterwards so that there are no residues of the cleaner on these parts It is absolutely necessary to watch out for some fundamental things to keep this longliving high grade steel machine working alway...

Page 18: ...soft cloth to avoid scratches Drawers GN Pans Easily removable without tools for separate cleaning Air openings evaporator All air openings as well as the evaporator need to be cleaned regularly to en...

Page 19: ...work and replacement of defect parts If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid Checklist for your Cold Display Cabinet 1...

Page 20: ...20 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 Wiring Diagrams 6 3 1 KT 700 230V 50Hz 1 N 6 3 2 KT 700 DB 230V 50Hz 1 N...

Page 21: ...Maintenance 21 printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 3 KT 1100 230V 50Hz 1 N 6 3 4 KT 1100 DB 230V 50Hz 1 N...

Page 22: ...22 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 5 KT 1400 230V 50Hz 1 N 6 3 6 KT 1400 DB 230V 50Hz 1 N...

Page 23: ...Maintenance 23 printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 7 KT 700 2 UL 120V 50Hz 1 N 6 3 8 KT 700 2 DB UL 120V 50Hz 1 N...

Page 24: ...24 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 9 KT 1100 2 UL 120V 50Hz 1 N 6 3 10 KT 1100 2 DB UL 120V 50Hz 1 N...

Page 25: ...Maintenance 25 printed 02 2015 Subject to change TopLineUserManualKT docx 6 3 11 KT 1400 2 UL 120V 50Hz 1 N 6 3 12 KT 1400 2 DB UL 120V 50Hz 1 N...

Page 26: ...ed out only by their service personal or by your authorized Service companies If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid A...

Page 27: ...ing unit KT 700 KT 700 DB 346104 1 17 cooling unit KT 700 2 KT 700 2DB 346115 1 18 thermometer 40 C to 40 C KT 700 KT 700 DB 342908 1 18 thermometer 40 F to 100 F KT 700 2 KT 700 2DB 342911 1 19 tumbe...

Page 28: ...ast KT 1100 2DB 340633 1 17 cooling unit KT 1100 KT 1100 DB 346105 1 17 cooling unit KT 1100 2 KT 1100 2DB 346116 1 18 thermometer 40 C to 40 C KT 1100 KT 1100 DB 342908 1 18 thermometer 40 F to 100 F...

Page 29: ...t KT 1400 KT 1400 DB 346106 1 17 cooling unit KT 1400 2 KT 1400 2DB 346116 1 18 thermometer 40 C to 40 C KT 1400 KT 1400 DB 342908 1 18 thermometer 40 F to 100 F KT 1400 2 KT 1400 2DB 342911 1 19 tumb...

Page 30: ...30 Maintenance printed 02 2015 Subject to change TopLineUserManualKT docx 6 5 Declaratoin Of Conformity...

Reviews: