background image

U.S. 

Solid®•

USS-DBS Models • All Rights Reserved • 

Page 1

U.S. 

Solid® 

 

• 1200 E.55th Unit C, Cleveland, OH, 44103 • www.ussolid.com   

USS-DBS

MODELS

OPERATING 

MANUAL

ANALYTICAL BALANCES

 This manual should be made available to all users of this 

equipment. For best results, and for maximum durability of the 

equipment, carefully read and follow all instructions.

ANALYTICAL BALANCE

Summary of Contents for USS-DBS3-1

Page 1: ... C Cleveland OH 44103 www ussolid com USS DBS MODELS OPERATING MANUAL ANALYTICAL BALANCES This manual should be made available to all users of this equipment For best results and for maximum durability of the equipment carefully read and follow all instructions ANALYTICAL BALANCE ...

Page 2: ...l Rights Reserved Page 2 U S Solid 1200 E 55th Unit C Cleveland OH 44103 www ussolid com I Getting Started II Specifications III Panel Description IV Installation V Using the Balance VI Maintenance and Cleaning Table of Contents ...

Page 3: ...s Be careful when handling the balance Avoid any sudden movements when in its vicinity Be sure to not drop the balance nor drop any heavy sharp objects on it Keep liquids away from the balance to avoid spills Never take apart the balance to try and fix yourself This could ruin the entire balance and voids the product warranty There is also risk of injury when disassembling the balance To prevent f...

Page 4: ...solid com FEATURES Straing gauge technology Stainless steel pan Backlit LCD display Plastic draft shield Height adjustable feet Taring Four different units of measure g lb ct oz Piece counting function ALWAYS MAKE SURE YOU CALIBRATE YOUR SCALE BEFORE USING AND NEVER TOUCH THE INCLUDED WEIGHT WITH YOUR SKIN ...

Page 5: ...in gauge technology for fast efficient measurement Technical Parameters MODEL USS DBS3 1 USS DBS3 2 USS DBS3 3 USS DBS3 5 Max Capacity in grams 100 200 300 500 Accuracy Class Class II Min Capacity 10 mg Division 0 001g Linearity 0 002 g Repeatability 0 002 g Operating Temperature 5 C 35 C with fluctuations of 1 C Hour 41 F 95 F with fluctuations of 1 8 F Hour Relative Hu midity 50 85 Power AC 110V...

Page 6: ... 6 U S Solid 1200 E 55th Unit C Cleveland OH 44103 www ussolid com III Panel Description Panel Explanations 1 ON OFF Turns device on and off 2 UNIT Select between ct oz lb g 3 PCS Piece counting mode 4 CAL Calibration key 5 TARE ZERO Tare the balance ...

Page 7: ...ance in areas with high humidity or high levels of dust 6 When moving from a cooler to a warmer place the accuracy and reliability of the scale will be influenced by the moisture con densation inside the balance In order to eliminate this influence it is best to leave the scale unplugged in its new location for at least two hours before next use 7 Avoid extreme temperatures or exposure to direct s...

Page 8: ... the display e g 100 0000 g 200 0000g etc depending on the model 3 Remove the weight from the pan 4 The balance will enter weighing mode and will display 0 000g or 0 0000g Note Each balance includes the necessary weight to complete external calibra tion Tare function 1 Put the receptacle on the weighing pan its weight will be displayed 2 Press TARE key and the reading on the display will automatic...

Page 9: ... in a wedged in location such as a shelf Never use other objects such as pens pencils etc to press the but tons on the control panel use only your fingers Never place anything on the pan heavier than the maximum capaci ty of the balance or the sensor could be damaged Do not submerge the balance nor spill any liquids on it If any liquid does come into contact with the electrical parts of the balanc...

Page 10: ...acles have been tared and the balance has been properly calibrated Display shows Item being weighed is over maximum allowable weight Make sure balance is properly cali brated and make sure item is below maximum allowable weight Display shows Err 1 Power issues with the balance Machine may have a poor power con nection Check the power in the back and the outlet Leave machine off for seveeral minute...

Page 11: ...aboratories Determining the price or total amount in sale price or in pre packaged preparations Instructions on environmental protection At the end of its life cycle please do not dispose of this equipment by throwing it in the usual garbage Instead hand it over at a collection point for the recycling of electrical and electronic appliances It does not contain dangerous nor toxic products for huma...

Page 12: ...U S Solid USS DBS Models All Rights Reserved Page 12 U S Solid 1200 E 55th Unit C Cleveland OH 44103 www ussolid com ...

Reviews: