U.S. Solid 10003 Instruction Manual Download Page 5

Data

 

sheet

Electronic

 

Analytical

 

Balance(0.01mg

 

external

 calibration)

Electronic

 

Analytical

 

Balance(0.01mg

 

internal

 

calibration)

Electronic

 

Analytical

 

Balance(1mg

 

internal

 

calibration)

Modle

Modle

Data sheet

Electronic

 

Analytical

 

Balance(1mg

 

external

 

calibration)

Capacity

Readability

Stable time

Preheating

Weighing units

Min weighting

Repeatability

Linearity

Interface

Pan size

Product size

N.W.

Power

Capacity

Capacity

Readability

Stable time

Preheating

Weighing units

Min weighting

Repeatability

Linearity

Interface

Pan size

Product size

N.W.

Power

Capacity

Capacity

Readability

Stable time

Preheating

Weighing units

Min weighting

Repeatability

Linearity

Interface

Pan size

Product size

N.W.

Power

Capacity

Readability

Stable time

Preheating

Weighing units

Min weighting

Repeatability

Linearity

Interface

Pan size

Product size

N.W.

Power

Model

Model

Model

Model

1

0035

10035

N

10055

10055N

1

0085

10085N

2

0035X

2

0035N

20055

20055N

20085

2

0085N

100g/30g

100g/30g

100g/50g

100g/50g

100g/80g

100g/80g

200g/30g

200g/30g

200g/50g

200g/50g

200g/80g

200g/80g

0.1mg/0.01mg

0.1mg/0.01mg

3s

3

s

30-60 mins

30-60 mins

g/oz/ct/mg

g/oz/ct/mg

0.1mg

/0.05mg

0.1mg

/0.05mg

±0.1mg

/±0.05mg

±0.2mg

/±0.05mg

RS232/USB

optional

RS232/USB

optional

φ90mm

φ90mm

31cm*21.2cm*35cm

31cm*21.2cm*35cm

5500g

5500g

AC110V-240V

AC110V-240V

1003

1003N

2003

2003

N

3003

3003N

5003

5003N

6003

6003N

10003

10003N

0--100g

0--100g

0--200g

0--200g

0--300g

0--300g

0--500g

0--500g

0-600g

0-600g

0--1000g

0--1000g

1mg

1mg

1

s

2s

30-60 mins

30-60 mins

g/oz/ct/mg

g/oz/ct/mg

1mg

1mg

±

1

mg

±

1

mg

±2mg

±2mg

RS232/USB

optional

RS232/USB

optional

φ90mm

φ90mm

31cm*21.2cm*35cm

31cm*21.2cm*35cm

5500g

5500g

AC110V-240V

AC110V-240V

2

0003

0--

2

000g

1mg

3

s

±

3

mg

±

4

mg

±0.1mg

/±0.05mg

±0.2mg

/±0.05mg

Summary of Contents for 10003

Page 1: ...Analytical Balance Instruction Manual For questions or concerns e mail service ussolid com visit www ussolid com or call 800 243 5428 ...

Page 2: ... calibration weight value setting linearity calibration 4 OPERATION unit conversion piece counting percent weighing density determination dynamic weighing baud rate print setting sensitivity setting filter level setting time setting 5 TROUBLESHOOTING 6 COMPONENTS LIST interface ...

Page 3: ...d quantity of objects Safety Precautions Verify that the AC Adapter input voltage matches the local AC power supply Use the scale only in dry locations For best results use the scale in the specified optimum operating temperature Use your scale with care gently loading items to be weighed onto the center of the pan Avoiding rough treatment will aid in the life of your scale Do not suggest to use i...

Page 4: ...r Capacity Electronic Analytical Balance 0 1mg internal calibration 1004 0 100g 1204 0 120g 2004 0 200g 2204 0 220g 3004 0 300g 3204 0 320g 4204 0 420g 5204 0 520g 0 1mg 2s 30 60 mins g oz ct mg 0 1mg 0 2mg 0 3mg 0 1mg 0 2mg RS232 USB optional φ90mm 31cm 21 2cm 35cm 5500g AC110V 240V Model Capacity Readability Stable time Preheating Weighing units Min weighting Repeatability Linearity Interface Pa...

Page 5: ...ts Min weighting Repeatability Linearity Interface Pan size Product size N W Power Model Model Model Model 10035 10035N 10055 10055N 10085 10085N 20035X 20035N 20055 20055N 20085 20085N 100g 30g 100g 30g 100g 50g 100g 50g 100g 80g 100g 80g 200g 30g 200g 30g 200g 50g 200g 50g 200g 80g 200g 80g 0 1mg 0 01mg 0 1mg 0 01mg 3s 3s 30 60 mins 30 60 mins g oz ct mg g oz ct mg 0 1mg 0 05mg 0 1mg 0 05mg 0 1m...

Page 6: ...hours under the power on state to adapt the balance to the new temperature Attention If the number on display is not stable at the first usage it is caused by the temperature difference of the environment you can press TARE button repeatedly and let it stand for 30 minutes In order to get accurate weighing result balance should be calibrated before the below usage scenarios Before first use Balanc...

Page 7: ...s from CAL 0 to CAL 200 and flashes put on the 200g weight for FA2204X model display shows 200 0000 remove the weight and finish the calibration internal calibration weight value setting internal calibration balance choose the calibration CAL 2 follow 3 2 2 press CAL button the display shows CAL DN put on the standard calibration weight accordingly the display shows CAL UP remove the weight wait f...

Page 8: ...on procedure Unit conversion under the weighing interface press and hold PRINT to change the unit the default unit g oz ct mg other unit is optional piece counting setting press and hold ON button under weighing interface balance enter into main menu wait until the display to show SEt 0 release the ON button press and hold PRINT enter into piece counting sample quantity setting the display shows C...

Page 9: ...e the sample weight the display shows 100 00 If the same contrast is used the second time no re sampling is required Long press PRINT button to exit the percent weighing and return to the weighing mode Density determination need gravity kit optional density weighing setting press and hold ON button the balance enters into the main menu mode when the display shows SET d release the button press and...

Page 10: ...isplay will show the result of density W1 W2 no display press and hold RPINT to exit density result Follow 4 4 setting set the density weighing to dEn 0 press TARE button to exit density determination Dynamic weighing function dynamic weighing setting press and hold ON button under weighing interface the balance enters into the main menu mode release the ON button until the display shows SET 5 pre...

Page 11: ...enter into baud rate setting display shows F press and hold PRINT to set up baud rate the display shows baud rate 1200 baud rate 2400 baud rate 4800 baud rate 9600 press TARE to save the setting and exit Print setting press and hold ON button under weighing interface the balance enters into the main menu mode release ON button until the display shows SET P press and hold PRINT to enter into print ...

Page 12: ...just the sensitivity without consulting the factory Filter level setting press and hold ON button under weighing interface the balance enters into the main menu mode release ON button until the display shows SET 1 press and hold PRINT button to enter into filter level setting the display shows Int press and hold PRINT button to set up filter level the display shows filter level highest filter leve...

Page 13: ...rface CLOC CLOC CLOC 4 OPERATION RS232 interface Connection Balance 9 pins PC Printer 9 pins RXD Input 2 2 TXD Output 3 3 GND Ground 5 5 Output data format Type or Àda ta data data data data data data data unit unit unit return data or dot data or dot Line feed The baudrate by default is 9600 bps see Baudrate setting Data format 10 bits 0 as start bit 1 as stop bit 8 digits ASCII code No odd and e...

Page 14: ...ontal Plug in adapter Change the fuse Change the power transformer If problem persists send the balance to the Technical Service for repair Improve the working condition Close the windshield Remove the pan and clean well the balance surface Connect the balance to power supply 110 220 V AC Static Elimination Make calibration Make tare Put into suitable enviroment Adjust level of balance Balance Bal...