U.S. Solid 10003 Instruction Manual Download Page 4

DISPLAY INFORMATION

No.

Display

Description

sensitivity

Dynamic weighing

Density

determination

Percent weighing

Piece counting

Time setting

Weight in air

Weight in liquid

Positive weight value

Negative weight

value

Stable value

Progress bar

Unit display

Data

 

sheet

Electronic

 

Analytical

 

Balance(0.1mg

 

external

 

calibration)

Capacity

Readability

Stable time

Preheating

Weighing units

Min weighting

Repeatability

Linearity

Interface

Pan size

Product size

N.W.

Power

Capacity

Electronic

 

Analytical

 

Balance(0.1mg

 

internal

 

calibration)

1004

0--100g

1204

0--120g

2

004

0--200g

2204

0--220g

3004

0-300g

3

204

0--320g

4204

0-420g

5204

0-520g

0.1mg

2s

30-60 mins

g/oz/ct/mg

0.1mg

±0.

2

mg

±0.

3

mg

±0.

1

mg

±0.

2

mg

RS232/USB(optional)

φ90mm

31cm*21.2cm*35cm

5500g

AC110V-240V

Model

Capacity

Readability

Stable time

Preheating

Weighing units

Min weighting

Repeatability

Linearity

Interface

Pan size

Product size

N.W.

Power

Model

1004

N

1

204

N

2004

N

2204

N

3004

N

3

204

N

4004

N

5004

N

0 - - 1 0 0 g

0 - - 1 2 0 g

0 - - 2 0 0 g

0 - - 2 2 0 g

0-300g

0--320g

0-400g

0-500g

0.1mg

2s

30-60 mins

g/oz/ct/mg

0.1mg

±0.

1

mg

±0.

2

mg

±0.

2

mg

±0.

3

mg

RS232/USB(optional)

φ90mm

31cm*21.2cm*35cm

5500g

AC110V-240V

Summary of Contents for 10003

Page 1: ...Analytical Balance Instruction Manual For questions or concerns e mail service ussolid com visit www ussolid com or call 800 243 5428 ...

Page 2: ... calibration weight value setting linearity calibration 4 OPERATION unit conversion piece counting percent weighing density determination dynamic weighing baud rate print setting sensitivity setting filter level setting time setting 5 TROUBLESHOOTING 6 COMPONENTS LIST interface ...

Page 3: ...d quantity of objects Safety Precautions Verify that the AC Adapter input voltage matches the local AC power supply Use the scale only in dry locations For best results use the scale in the specified optimum operating temperature Use your scale with care gently loading items to be weighed onto the center of the pan Avoiding rough treatment will aid in the life of your scale Do not suggest to use i...

Page 4: ...r Capacity Electronic Analytical Balance 0 1mg internal calibration 1004 0 100g 1204 0 120g 2004 0 200g 2204 0 220g 3004 0 300g 3204 0 320g 4204 0 420g 5204 0 520g 0 1mg 2s 30 60 mins g oz ct mg 0 1mg 0 2mg 0 3mg 0 1mg 0 2mg RS232 USB optional φ90mm 31cm 21 2cm 35cm 5500g AC110V 240V Model Capacity Readability Stable time Preheating Weighing units Min weighting Repeatability Linearity Interface Pa...

Page 5: ...ts Min weighting Repeatability Linearity Interface Pan size Product size N W Power Model Model Model Model 10035 10035N 10055 10055N 10085 10085N 20035X 20035N 20055 20055N 20085 20085N 100g 30g 100g 30g 100g 50g 100g 50g 100g 80g 100g 80g 200g 30g 200g 30g 200g 50g 200g 50g 200g 80g 200g 80g 0 1mg 0 01mg 0 1mg 0 01mg 3s 3s 30 60 mins 30 60 mins g oz ct mg g oz ct mg 0 1mg 0 05mg 0 1mg 0 05mg 0 1m...

Page 6: ...hours under the power on state to adapt the balance to the new temperature Attention If the number on display is not stable at the first usage it is caused by the temperature difference of the environment you can press TARE button repeatedly and let it stand for 30 minutes In order to get accurate weighing result balance should be calibrated before the below usage scenarios Before first use Balanc...

Page 7: ...s from CAL 0 to CAL 200 and flashes put on the 200g weight for FA2204X model display shows 200 0000 remove the weight and finish the calibration internal calibration weight value setting internal calibration balance choose the calibration CAL 2 follow 3 2 2 press CAL button the display shows CAL DN put on the standard calibration weight accordingly the display shows CAL UP remove the weight wait f...

Page 8: ...on procedure Unit conversion under the weighing interface press and hold PRINT to change the unit the default unit g oz ct mg other unit is optional piece counting setting press and hold ON button under weighing interface balance enter into main menu wait until the display to show SEt 0 release the ON button press and hold PRINT enter into piece counting sample quantity setting the display shows C...

Page 9: ...e the sample weight the display shows 100 00 If the same contrast is used the second time no re sampling is required Long press PRINT button to exit the percent weighing and return to the weighing mode Density determination need gravity kit optional density weighing setting press and hold ON button the balance enters into the main menu mode when the display shows SET d release the button press and...

Page 10: ...isplay will show the result of density W1 W2 no display press and hold RPINT to exit density result Follow 4 4 setting set the density weighing to dEn 0 press TARE button to exit density determination Dynamic weighing function dynamic weighing setting press and hold ON button under weighing interface the balance enters into the main menu mode release the ON button until the display shows SET 5 pre...

Page 11: ...enter into baud rate setting display shows F press and hold PRINT to set up baud rate the display shows baud rate 1200 baud rate 2400 baud rate 4800 baud rate 9600 press TARE to save the setting and exit Print setting press and hold ON button under weighing interface the balance enters into the main menu mode release ON button until the display shows SET P press and hold PRINT to enter into print ...

Page 12: ...just the sensitivity without consulting the factory Filter level setting press and hold ON button under weighing interface the balance enters into the main menu mode release ON button until the display shows SET 1 press and hold PRINT button to enter into filter level setting the display shows Int press and hold PRINT button to set up filter level the display shows filter level highest filter leve...

Page 13: ...rface CLOC CLOC CLOC 4 OPERATION RS232 interface Connection Balance 9 pins PC Printer 9 pins RXD Input 2 2 TXD Output 3 3 GND Ground 5 5 Output data format Type or Àda ta data data data data data data data unit unit unit return data or dot data or dot Line feed The baudrate by default is 9600 bps see Baudrate setting Data format 10 bits 0 as start bit 1 as stop bit 8 digits ASCII code No odd and e...

Page 14: ...ontal Plug in adapter Change the fuse Change the power transformer If problem persists send the balance to the Technical Service for repair Improve the working condition Close the windshield Remove the pan and clean well the balance surface Connect the balance to power supply 110 220 V AC Static Elimination Make calibration Make tare Put into suitable enviroment Adjust level of balance Balance Bal...

Reviews: