Part # 3052000 (09/16/09)
Page 10
INSTALLATION
INTRODUCTION
Uncratingl
1. Check crate for possible damage sustained during transit.
Carefully remove unit from crate and again check for
damage. Any damage to the appliance must be reported
to the carrier immediately.
2. The wires for retaining the burners and other packing
material must be removed from units. Any protective
material covering stainless steel parts must also be
removed.
3. All equipment is shipped from the factory with legs
fitted, unless otherwise specified. Where the range is to
be mounted on a dial or cove base, it is shipped without
legs. Legs must be fitted to the oven where it is installed
on a combustible floor.
4. The type of gas and supply pressure that the equipment
was set-up for at the factory is noted on the data plate
and on the packaging. This type of gas supply must be
used.
5. Do not remove permanently affixed labels, warnings or
data plates from the appliance, for this may invalidate the
manufacturer’s warranty.
Rating Plate
Every cooking unit has a rating plate. Information on this
plate includes model and serial numbers. Knowing the
equipment model and serial number is essential if spare
parts are required or for discussing equipment problems
with Garland’s technical support staff. Other information
on the rating plate indicates BTU/hr output of the burners,
outlet gas pressure in inches water column (WC) and
whether orifices are for natural or propane gas. The following
table gives the location of the rating plate on the designated
models, and Table B in the Specification Section lists the
various models of heavy duty equipment in the U.S. range
gas operated Cuisine series.
MODEL WITH SUFFIX
LOCATION
Oven Or
Convection Oven Base
Behind the lower kick panel
Storage Cabinet Base
In the storage cabinet on
the left hand side panel
Modular Top
On the front panel
NOTE: Cuisine heavy duty gas operated equipment must
be connected only to the type of gas identified on the rating
plate!
Clearances
MODELS
CLEARANCES
C836-436A-436ARC
Installation in Non-
Combustible Locations
Only with 0” Side & Rear
Clearance
C836-36A-36ARC
C0836-324A,-336A
C0836-424A,-436A
C0836-24A,-36A
C0836-24AM,-36AM
All Other Models
7” (172mm )Side, 6”
(152mm) Rear, from
Combustible Base
1. All models may be installed with 0” side and rear
clearance from non-combustible construction.
2 For models sited on combustible and non-combustible
floor bases the required clearances are 7”(172mm) sides
and 6” (152mm) rear.
NOTE: When installed without legs on a non-combustible
curb or platform, front of unit should extend at least 3 inches
(76mm).
NOTE: Adequate clearance must be provided for servicing
and proper operation.
Installation Procedure
1. Remove all packing material.
2. Remove the front valve panel.