Part Number 1955202 1/15
7
DIMENSIONS AND SPECIFICATIONS, MODEL SUMG
“D”
TOP VIEW
38"
[965mm]
25-3/8"
[645mm]
54-9/16"
[1386mm]
3/4" N.P.T.
GAS INLET
3/4" REAR
GAS INLET
1" REAR
GAS INLET
7-3/4"
[197mm]
2"
[51mm]
3/4"
[19mm]
(includes
motor)
FLUE: 2-3/8" x 5"
[60mm x 127mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
34"
[864mm]
SINGLE DECK
FRONT VIEW
6-1/4"
[159mm]
DOUBLE DECK
FRONT VIEW
32-1/8"
[816mm]
32-1/8"
[816mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
32-1/8"
[816mm]
14-3/4"
[375mm]
35-7/16"
[900mm]
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V 3/4 HP, 2-speed motor; 1140 and 1725 rpm 60Hz
3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz.
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug..
5. U.S. Range recommends a separate 15 AMP circuit for each 120V unit.
Installation Notes:
Combustible & Non-Combustible
Wall Clearances:
Sides
1" (25mm)
Back
3" (76mm)
Entry Clearances: In (mm)
Crated
44-1/2 (1130) Uncrated 32-1/2 (826)
Model
Int. Dimensions: inch (mm)
Ext. Dimensions: inch (mm)
Ship Wt
Ship Dim.
W
H
D
W
H
D(w/motor)
Lbs/kg
Cubic Ft.
SUMG-100
29 (736)
24 (610)
24 (610)
38 (965)
57-1/2 (1461)
41-1/4 (1048)
515 / 230
64
SUMG-200
29 (736)
24 (610)
24 (610)
38 (965)
70-1/2 (1791)**
41-1/4 (1048)
1030 / 465
128
SUMG-GS-10-ESS
29 (736)
24 (610)
24 (610)
38 (965)
57-1/2 (1461)
41-1/4 (1048)
515 / 230
64
SUMG-GS-20-ESS
29 (736)
24 (610)
24 (610)
38 (965)
70-1/2 (1791)**
41-1/4 (1048)
1030 / 465
128
** Height with legs or with standard casters. Height with low profile casters (double deck) is 68-1/2” (1740mm).
Models
Input Ratings
Operating Pressure*
Electrical Specifications
BTU/hr
kW Equiv.
Gas Inlet
Natural
Propane
120V/1Ph.
240V/1Ph.
SUMG-100
Natural &
Propane
53 000
15.53
(1) @ 3/4" NPT
4" WC
(10 mbar)
10" WC
(25 mbar)
(1) @9.8A
(1) @ 5.2A
SUMG-200
106 000
31.06
(1) @1" NPT
(2) @9.8A
(2) @ 5.2A
SUMG-GS-10-ESS
Natural
Gas
53 000
15.53
(1) @ 3/4” NPT
4” WC
(10 mbar)
n/a
(1) @9.8A
(1) @ 5.2A
SUMG-GS-20-ESS
106 000
31.06
(1) @1” NPT
(2) @9.8A
(2) @ 5.2A
*Maximum Pressure 13.8” WC @ 70°F (21°C).
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
These appliances are intended for commercial use by professionally trained personnel.
Summary of Contents for Manitowoc Summit series
Page 2: ......
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 6: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 22: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 23: ......
Page 26: ......
Page 27: ...CETTE PAGE EST LAISS E BLANCHE INTENTIONNELLEMENT...
Page 43: ...CETTE PAGE EST LAISS E BLANCHE INTENTIONNELLEMENT...
Page 45: ...CETTE PAGE EST LAISS E BLANCHE INTENTIONNELLEMENT...
Page 47: ......