background image

SKU 66974 

For technical questions, please call 1-800-444-3353. 

Page 10

maintenanCe and 

SerViCing

  Procedures not specifically 

explained in this manual 

must be performed only by a 

qualified technician.

 

to PreVent 

SeriouS injury 

From aCCidental 

oPeration: 

turn the on/off lever of the 

Compressor to its “oFF” 

position, pull the Safety Valve 

to release excess pressure in 

the tank, and unplug from its 

electrical outlet before 

performing any inspection, 

maintenance, or cleaning 

procedures.
to PreVent SeriouS 

injury From tool 

Failure: 

do not use damaged 

equipment.  if abnormal noise 

or vibration occurs, have the 

problem corrected before 

further use.

Cleaning, maintenance, and 

lubrication

BeFore eaCH uSe,

1. 

 inspect the 

general condition of the tool.  Check 

for loose screws, air leaks, damaged 

air pressure related gauges, damage 

to the Regulator or Shut Off Valve, 

and any other condition that may af-

fect its safe operation.

aFter uSe,

2. 

 clean external surfaces 

of the tool with clean cloth.

3. 

Warning!  if the supply cord of 

this power tool is damaged, it must 

be replaced only by a qualified 

service technician.

PleaSe read tHe FolloWing 

CareFully

THE MANUFACTURER AND/OR DISTRIBUTOR 

hAS PROvIDED ThE PARTS LIST AND 

ASSEMBLy DIAgRAM IN ThIS MANUAL AS 

A REFERENCE TOOL ONLy.  NEIThER ThE 

MANUFACTURER OR DISTRIBUTOR MAKES 

ANY REPRESENTATION OR WARRANTY OF 

ANY KIND TO THE BUYER THAT HE OR SHE 

IS qUALIFIED TO MAkE ANy REPAIRS TO ThE 

PRODUCT, OR ThAT hE OR ShE IS qUALIFIED 

TO REPLACE ANy PARTS OF ThE PRODUCT.  

IN FACT, THE MANUFACTURER AND/OR 

DISTRIBUTOR ExPRESSLy STATES ThAT 

ALL REPAIRS AND PARTS REPLACEMENTS 

ShOULD BE UNDERTAkEN By CERTIFIED 

AND LICENSED TEChNICIANS, AND NOT By 

ThE BUyER.  ThE BUyER ASSUMES ALL RISk 

AND LIABILITy ARISINg OUT OF hIS OR hER 

REPAIRS TO ThE ORIgINAL PRODUCT OR 

REPLACEMENT PARTS ThERETO, OR ARISINg 

OUT OF hIS OR hER INSTALLATION OF 

REPLACEMENT PARTS ThERETO.

Summary of Contents for 66974

Page 1: ...is manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consen...

Page 2: ...ndicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol...

Page 3: ...ntentional starting c Ensure the On Off Lever is in the off position before connecting to power source or moving the Com pressor Do not overreach Keep proper d footing and balance at all times This en...

Page 4: ...n output pressure greater than marked maximum pres sure of attachment Risk of injury do not direct air 3 stream at body To reduce the risk of electric shock do not expose to rain Store indoors Do not...

Page 5: ...y Code 25249 5 et seq WARNING Handling the cord on 14 this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash...

Page 6: ...ected through the green wire in side the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached t...

Page 7: ...arbor Freight Tools at the number shown on the cover of this manual as soon as possible Instructions for putting into use Read the entire Important Safety Information section at the beginning of this...

Page 8: ...ch the work area with enough extra length to allow free movement while working Pull the Safety Valve to make sure 2 there is no residual pressure in the tank Following the tool manufacturer s in 3 str...

Page 9: ...pressure range The Air Compressor will cycle up to 8 100 PSI before shutting off It will start to build pressure again when the air pressure in the air tank drops to 58 PSI After the job is complete...

Page 10: ...ut Off Valve and any other condition that may af fect its safe operation After Use 2 clean external surfaces of the tool with clean cloth 3 WARNING If the supply cord of this power tool is damaged it...

Page 11: ...serviced by a qualified technician 2 Overheating Poor ventilation 1 Compressor undersized for 2 application Move the compressor to an area with better 1 air circulation Check air requirements of tools...

Page 12: ...ushion 5 4 Part Description Qty 31 Stator 1 32 Bolt 2 33 Rotor 1 34 Bearing 6203 2z 2 35 Pressure Gauge 1 36 On Off Lever 1 37 Safety Valve 1 38 Power Line with Plug 1 39 Connector Bolt 1 40 Regulator...

Page 13: ...SKU 66974 For technical questions please call 1 800 444 3353 Page 13 ASSEMBLY DIAGRAM 57 41 40 38 39 56 37 36 35 47 46 58 60 59 49 REV 09f...

Page 14: ...ecial or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limita tion of exclusion may...

Reviews: