B. CPVC/PVC Venting (continued)
Table 7C: CPVC/PVC Vent & Air Intake Components (Installer Provided for Optional Vertical (Roof)
Termination (Applicable to Twin-Pipe Venting with Separate Vent & Air Intake Roof Terminations)
Vent Components
Part
Number
Quantity
ALP080B & ALP105B
Vertical (Roof)
Termination
ALP150B & ALP210B
Vertical (Roof)
Termination
ALP285B
Vertical (Roof) Termination
2" Schedule 40 PVC Coupling (Vent)
N/A
Supplied by
Others
1
N/A
N/A
3” Schedule 40 PVC Coupling (Vent)
N/A
1
N/A
4" Schedule 40 PVC Coupling (Vent)
N/A
N/A
1
2” Schedule 40 PVC 90° Elbow (Air Intake)
2
N/A
N/A
3" Schedule 40 PVC 90° Elbow (Air Intake)
N/A
2
N/A
4" Schedule 40 PVC 90° Elbow (Air Intake)
N/A
N/A
2
2” Schedule 40 CPVC Pipe x ½ ft. min. horizontal run
1
N/A
N/A
3" Schedule 40 CPVC Pipe x ½ ft. min. horizontal run
N/A
1
N/A
4" Schedule 40 CPVC Pipe x ½ ft. min. horizontal run
N/A
N/A
1
Table 7D: Components (Installer Provided) Required for Optional IPEX Low Profile Horizontal
Termination
Description
Ipex Part Number
Applicable to Boiler Models
2” Low Profile Termination Kit
196894
ALP080B, ALP105B
3” Low Profile Termination Kit
196895
ALP150B, ALP210B
4” Low Profile Termination Kit
196896
ALP285B
Table 7E: Components (Installer Provided) Required for Optional DiversiTech
(HVENT) Low Profile Horizontal Termination
Description
DiversiTech (HVENT) Part Number
Applicable to Boiler Models
2” Low Profile Termination Kit
HVENT2
ALP080B, ALP105B
3” Low Profile Termination Kit
HVENT3
ALP150B, ALP210B
4” Low Profile Termination Kit
NA
ALP285B
Table 7F: Components (Installer Provided) Required for Optional Ipex (FGV) Concentric Horizontal
Or Vertical Termination
Description
Ipex (FGV) Part Number
Applicable to Boiler Models
2” Termination Kit
196105
ALP080B, ALP105B
3” Termination Kit
196106
ALP150B, ALP210B
4” Termination Kit
NA
ALP285B
Table 7G: : Components (Installer Provided) Required for Optional DiversiTech
(CVENT) Concentric Horizontal Or Vertical Termination
Description
DiversiTech (HVENT) Part Number
Applicable to Boiler Models
2” Termination Kit
CVENT2
ALP080B, ALP105B
3” Termination Kit
CVENT3
ALP150B, ALP210B
4” Termination Kit
NA
ALP285B
Summary of Contents for Alpine ALP080B
Page 76: ...76 103448 10 6 18 VIII Electrical continued...
Page 77: ...103448 10 6 18 77 VIII Electrical continued Figure 27 Wiring Connection Diagram...
Page 78: ...78 103448 10 6 18 Figure 28 Ladder Diagram VIII Electrical continued...
Page 146: ...146 103448 10 6 18...