USER GUIDE
Quick Guide
Quick Guide
0. Exit
1.
Thermistor 1 temperature not including offsets.
2.
Thermistor 2 temperature not including offsets.
3.
Thermistor 3 temperature not including offsets.
4.
Thermistor 4 temperature not including offsets.
5.
Thermistor 1 offset. (+/- 10)
6.
Thermistor 2 offset. (+/- 10)
7.
Thermistor 3 offset. (+/- 10)
8.
Thermistor 4 offset. (+/- 10)
9.
Thermistor 2 set point
10.
Thermistor 3 set point.
11.
Thermistor 4 set point.
12.
Defrost Interval (0 to 99 hr)
13.
Defrost duration (0 to 99 min)
14.
Error Log (See Appx D)
15.
Clear error log (hold light key until cleared)
16.
Thermistor 1 differential (+5)
17.
Thermistor 3 differential (+5)
18.
Evaporator fan on delay (0 to 99 sec)
19.
Evaporator fan off delay (0 to 99 sec)
20.
Individual component toggle
-
Option #0 – Exit
-
Option #1 – Relay 1
-
Option #2 – Relay 2
-
Option #3 – Relay 3
-
Option #4 – Relay 4
-
Option #5 – Relay 5
-
Option #6 – Relay 6
-
Option #7 – DC Output 1
-
Option #8 – DC Output 2
-
Option #9 – DC Output 3
-
Option #10 – DC Output 4
-
Option #11 – DC Output 5
-
Option #12 – Serial output (Compressor)
21.
Model number
22.
Light All Segments
23.
Activate Defrost/Harvest- press and hold for 3
seconds to activate defrost/harvest
24.
Defaults- press and hold for 3 seconds to
restore all values to factory defaults.
25.
Main Software (Display only)
26.
Live Log Period (frequency that data is output
to diagnostics port)
27.
Factory test mode (0=Off, 1=On)
28.
Compressor RPM
29.
Freeze time adjust (Model 54 only)
30.
Harvest time adjust (Model 54 only)
31.
Low temp alarm limit (Model 55 only)
32.
High temp alarm limit (Model 55 only)
ERRORS
*All errors are logged in memory.
*Only door error is displayed on the display and has an
audible signal.
*For 68118 models, pump error is displayed via alert
light with no audible alert.
E1: Thermistor 1 open.
E2: Thermistor 2 open.
E3: Thermistor 3 open.
E4: Thermistor 4 open.
E5: Thermistor 1 shorted.
E6: Thermistor 2 shorted.
E7: Thermistor 3 shorted.
E8: Thermistor 4 shorted.
E9: Door 1 open error.
E10: (displayed as 10): Door 2 open
E11: (displayed as 11): Water level (tray or reservoir)
high.
E12: (displayed as 12): Water level low.
E13: Auger error
P1: Pump circuit open
SERVICE MENU
34