U-Line RUG DOCTOR H-10972 Manual Download Page 7

PAGE 7 OF 9 

1123 IH-10972

OPERATION CONTINUED

CARE AND STORAGE

MACHINE CARE 

•  Always use recommended Rug Doctor

®

 cleaning 

agents. Do not use dye or bleach in this machine. 

Dye and bleach will permanently damage carpets. 

•  Store indoors out of dusty, wet and freezing areas. 

This prolongs the life of Rug Doctor

®

 machine  and 

helps keep it trouble-free. 

•  Do not expose to freezing temperatures for 

prolonged periods of time. In freezing temperatures, 

liquid in the machine system can damage the 

pump and solution hoses. 

•  Use care when transporting Rug Doctor

®

 machine. 

Rug Doctor

®

 machines are designed for rugged use. 

However, avoid mishandling, such as dropping the 

unit or transporting it in an open van or truck. Jarring 

from sudden vehicle starts or stops can damage the 

machine. 

3.  When cleaning is complete, switch the machine to    

 "0" for the off position. 

4.  Disconnect both of the hoses from the machine. 

Holding the hose ends over a sink, squeeze the 

hand tool trigger until all liquid is drained. 

5.  To drain and clean the machine, refer to the 

Maintenance section on page 7. Reconnect the 

machine vacuum and solution hoses. 

NOTE: For velvet upholstery, fluff up damp pile 
with a soft brush or towel to keep from matting.

6.  Drain the machine by spraying out remaining 

solution over a floor drain or outdoors (never in rain 

or on wet ground). Do not allow machine to stand 

in liquid while emptying. For best results, spray out 

liquid with machine set to "Tool" to prevent brushes 

from movement and wear while emptying. Using this 

method, you can spray out remaining liquid either 

through Hand Tool or machine spray tips.

7.  Clean the vibrating brush by pulling down on the 

plastic brush body (Refer to Replacing A Brush 

Section). After each use, unplug the machine from 

power source and use your finger or an old comb 

to remove any debris from the vibrating brush. If 

you used any Rug Doctor attachments, also remove 

debris from the attachment vacuum slot.

8.  Clean the vacuum filter. After each use, inspect the 

cylindrical filter screen located inside of the clear 

plastic dome on the front of the machine. If debris is 

present, remove the filter screen by pushing it right 

and compressing the spring until the filter end is 

clear of the dome. Clean by running water through 

the screen from the inside to the outside. Replace 

by compressing the spring wire and inserting the 

black end securely into place in the hole inside  

the dome.

9.  Clean the solution tank filter screen. After each use, 

inspect the rectangular filter screen located in the 

fill opening of the solution (lower) tank. If debris is 

present, remove screws that hold the filter in place 

and remove filter from the solution tank opening. 

Clean filter by holding it under a water faucet and 

letting the water run through the filter in the opposite 

direction from the normal filling flow. Replace the 

filter screen and fasten it in place with the two 

mounting screws.

10. Clean the solution tank line strainer. When the 

solution tank filter screen is removed for cleaning, 

inspect the cylindrical filter mounted on the end of 

the solution line inside of the lower tank. If debris is 

present, remove the filter by pulling it off the solution 

line. Hold the filter under flowing water until debris 

is cleared. Replace the filter by pushing it over the 

end of the solution hose. 

11.  Remove carpet fibers from vacuum slot. Periodically 

check the vacuum slot on the bottom front of the 

machine for debris. Remove any fiber, hair or other 

debris that may be caught in the slot. Always ensure 

the machine is in the "0" position (for off), unplugged 

and the tanks are empty. 

Summary of Contents for RUG DOCTOR H-10972

Page 1: ...clude permanent staining of carpet Use caution when using hot tap water Do not boil or microwave water to be used in this machine Do not allow the machine to run dry When the solution tank runs out st...

Page 2: ...reproductive harm Connect to properly grounded outlet only See Grounding Instructions on page 3 WARNING Machine may contain water For best cleaning results and to avoid the risk of permanent damage to...

Page 3: ...to chemicals including Diethylhexyl Phthalate DEHP lead and other chemicals known to the state of California to cause cancer birth defects or possible reproductive harm For a complete list of warning...

Page 4: ...looped carpets retain more liquid For these types of carpets do not repeat cleaning passes If additional cleaning is desired allow carpets to dry before attempting to reclean heavily soiled areas Bec...

Page 5: ...tor Oxy Cleaning solution by pouring through the white filter screen Machine is full when liquid halfway covers the filter screen See Figure 5 5 Replace recovery tank and close the dome hood 6 Plug in...

Page 6: ...hly vacuuming or brushing When cleaning and drying cushions first spread sheets or towels on the floor as a drying surface for the dampened cushions 2 Disconnect the large vacuum hose Reconnect the to...

Page 7: ...h Section After each use unplug the machine from power source and use your finger or an old comb to remove any debris from the vibrating brush If you used any Rug Doctor attachments also remove debris...

Page 8: ...s lost vacuum pressure Ensure the dome hood is closed and securely sealed Check the hose connection at the back of the machine and secure if necessary Clean the filter that is in the dome Remove any a...

Page 9: ...e tip and blow air through it to remove any build up that may be clogging the tip Reattach the tip with the nut driver Ensure to position the tip opening so that it sprays side to side Check the lower...

Reviews: