U-Line RUG DOCTOR H-10972 Manual Download Page 6

PAGE 6 OF 9 

1123 IH-10972

OPERATION CONTINUED

IMPORTANT! When 

depressing the "press for 
spray" (red) button, keep 

machine moving so the 
vibrating brush does not 
agitate in one place. 
(See Figure 8) 

2.  Release the red button 6-12" 

before ending each pass to 

stop cleaning solution. Tilt 

machine back and push 

it forward to start a new 

backward cleaning pass. 

(See Figure 9) 

3.  Continue cleaning in this manner, overlapping 

each pass slightly. When the lower tank runs out of 

cleaning solution, the pump sound will increase in 

volume slightly and dirty water will stop entering the 

dome. Switch the machine to "0" for the off position. 

Remove and empty the recovery tank by pouring 

dirty solution into a toilet or outdoors. 

4.  Rinse the recovery tank and use a clean bucket 

to refill the lower tank with a clean solution/water 

mixture. If nearing the end of the cleaning job, fill 

the lower tank half full, so it is empty by the end of 

the job. Replace the recovery tank. 

5.  Continue the cleaning process until area to be 

cleaned is covered. When cleaning is complete, 

switch the machine to "0" for the off position. 

To drain and clean the machine, refer to the 

Maintenance section on page 7.

UPHOLSTERY CLEANING

NOTE: Upholstery tool  
(Uline model # H-10973) 
is sold separately. 

SETUP 

1.  Prepare surfaces for cleaning by thoroughly 

vacuuming or brushing. When cleaning and drying 

cushions, first spread sheets or towels on the floor as 

a drying surface for the dampened cushions. 

2.  Disconnect the large 

vacuum hose. Reconnect 

the top portion to the large 

vacuum hose of hand tool. 

Slide up the brass    

 "quick coupler" ring and pull 

out the small solution hose.  

(See Figure 10) 

3.  Slide up the ring again to insert the metal end of the 

hand tool solution hose. Release the brass ring to 

secure. Tug gently on the hose to make certain the 

connection is secure. 

4.  Remove the recovery tank, 

mix Rug Doctor® upholstery 

cleaner in a clean bucket 

according to label directions 

and pour into lower tank. 

(See Figure 11) 

5.  Slip the tank back in place  

and close the dome hood.  

(See Figure 12) Plug in the 

power cord and position the 

machine. 

6.  Turn on the machine by 

sliding the switch to the "Tool" 

position on the side of the 

handle. (See Figure 13)

START CLEANING 

1.  Test upholstery for colorfastness by first cleaning a 

small, hidden area, then rubbing the test area with 

a white paper towel. If no color appears, continue 

cleaning. A little color on the towel means there is 

some chance of color running, but it is likely it can 

still be cleaned safely. Try using cool or cold water 

and test again with a white paper towel. 

2.  Working at a slow, steady 

pace, begin cleaning by 

squeezing the hand tool 

lever as the tool is pulled 

over fabric. Overlap strokes 

slightly. (See Figure 14) 

Figure 11

Figure 12

Figure 13

Figure 8

Figure 9

Figure 10

H-10973

Figure 14

Summary of Contents for RUG DOCTOR H-10972

Page 1: ...clude permanent staining of carpet Use caution when using hot tap water Do not boil or microwave water to be used in this machine Do not allow the machine to run dry When the solution tank runs out st...

Page 2: ...reproductive harm Connect to properly grounded outlet only See Grounding Instructions on page 3 WARNING Machine may contain water For best cleaning results and to avoid the risk of permanent damage to...

Page 3: ...to chemicals including Diethylhexyl Phthalate DEHP lead and other chemicals known to the state of California to cause cancer birth defects or possible reproductive harm For a complete list of warning...

Page 4: ...looped carpets retain more liquid For these types of carpets do not repeat cleaning passes If additional cleaning is desired allow carpets to dry before attempting to reclean heavily soiled areas Bec...

Page 5: ...tor Oxy Cleaning solution by pouring through the white filter screen Machine is full when liquid halfway covers the filter screen See Figure 5 5 Replace recovery tank and close the dome hood 6 Plug in...

Page 6: ...hly vacuuming or brushing When cleaning and drying cushions first spread sheets or towels on the floor as a drying surface for the dampened cushions 2 Disconnect the large vacuum hose Reconnect the to...

Page 7: ...h Section After each use unplug the machine from power source and use your finger or an old comb to remove any debris from the vibrating brush If you used any Rug Doctor attachments also remove debris...

Page 8: ...s lost vacuum pressure Ensure the dome hood is closed and securely sealed Check the hose connection at the back of the machine and secure if necessary Clean the filter that is in the dome Remove any a...

Page 9: ...e tip and blow air through it to remove any build up that may be clogging the tip Reattach the tip with the nut driver Ensure to position the tip opening so that it sprays side to side Check the lower...

Reviews: