U-Line RUG DOCTOR H-10972 Manual Download Page 5

PAGE 5 OF 9 

1123 IH-10972

SETUP 

NOTE: Before cleaning, review machine safety 
warnings found in the front of these instructions. 
Using a normal dry vacuum cleaner, vacuum 
to remove loose dirt before using this machine. 

This will help keep the brushes and water 
vacuum system working efficiently. Pre-treat 
any special problem areas with appropriate 

Rug Doctor

®

 solutions.

1.  Check the back of the 

machine to ensure hose 

connections are secure and 

set to "clean carpet" instead 

of "upholstery". (See Figure 2)

2.  Lift up on the recovery latch 

and raise dome hood to 

remove the recovery tank. 

(See Figure 3) 

3.  Depending on how dirty 

carpets are, add 2-4 oz. 

(1/4-1/2 cup) of Rug Doctor

®

 

Oxy Carpet Cleaner  

(Uline model # S-25570) 

product per gallon of hot tap 

water in a clean bucket.  

(See Figure 4) 

CAUTION!  Ensure water is not so hot as to scald 
or burn skin. 

4.  The lower tank capacity is 

three gallons. Fill the lower  

tank with the Rug Doctor®  

Oxy Cleaning solution by 

pouring through the white filter 

screen. Machine is full when 

liquid halfway covers the filter 

screen. (See Figure 5)

5.  Replace recovery tank and close the dome hood. 

6.  Plug in the power cord and 

position the machine. Refer to  

the label on the side of the 

handle. Slide the switch to the    

 "Carpet" position for carpet 

cleaning. (See Figure 6)

START CLEANING 

1.  While depressing the red  

 "press for spray" button on  

top of the handle, pull the 

machine slowly and steadily 

backward in a straight line, 

keeping vacuum slot against 

the carpet surface. 

(See Figure 7) 

NOTE: For lightly soiled carpets, pull the 
machine quickly at one foot per second. For 
moderately or heavily soiled carpets, pull the 
machine at approximately one foot every two 
seconds. User will begin to see soiled solution 

entering the clear dome. (If not, stop and refer 
to the Troubleshooting section on pages 7-9). 

OPERATION CONTINUED

Spray Button

Handle Release

On/Off Switch

Reset Button

Dome Filter

Recovery Latch 

and Dome Hood

Lower Tank

Recovery Tank

Vacuum Slot

Figure 4

Figure 5

Figure 6

Figure 3

Figure 2

Figure 7

Upholstery Tool

Summary of Contents for RUG DOCTOR H-10972

Page 1: ...clude permanent staining of carpet Use caution when using hot tap water Do not boil or microwave water to be used in this machine Do not allow the machine to run dry When the solution tank runs out st...

Page 2: ...reproductive harm Connect to properly grounded outlet only See Grounding Instructions on page 3 WARNING Machine may contain water For best cleaning results and to avoid the risk of permanent damage to...

Page 3: ...to chemicals including Diethylhexyl Phthalate DEHP lead and other chemicals known to the state of California to cause cancer birth defects or possible reproductive harm For a complete list of warning...

Page 4: ...looped carpets retain more liquid For these types of carpets do not repeat cleaning passes If additional cleaning is desired allow carpets to dry before attempting to reclean heavily soiled areas Bec...

Page 5: ...tor Oxy Cleaning solution by pouring through the white filter screen Machine is full when liquid halfway covers the filter screen See Figure 5 5 Replace recovery tank and close the dome hood 6 Plug in...

Page 6: ...hly vacuuming or brushing When cleaning and drying cushions first spread sheets or towels on the floor as a drying surface for the dampened cushions 2 Disconnect the large vacuum hose Reconnect the to...

Page 7: ...h Section After each use unplug the machine from power source and use your finger or an old comb to remove any debris from the vibrating brush If you used any Rug Doctor attachments also remove debris...

Page 8: ...s lost vacuum pressure Ensure the dome hood is closed and securely sealed Check the hose connection at the back of the machine and secure if necessary Clean the filter that is in the dome Remove any a...

Page 9: ...e tip and blow air through it to remove any build up that may be clogging the tip Reattach the tip with the nut driver Ensure to position the tip opening so that it sprays side to side Check the lower...