U-Line RUG DOCTOR H-10972 Manual Download Page 1

PAGE 1 OF 9 

1123 IH-10972

H-10972

RUG DOCTOR

® 

CARPET CLEANER

1-800-295-5510

 uline.com

π

SAFETY

Please read all instructions before using. When using 
an electrical appliance, basic precautions should 
always be followed, including the following:

WARNING! To reduce the risk of fire, electric 
shock or injury: 

•  Do not leave appliance when plugged in. Unplug 

from outlet when not in use and before servicing. 

•  To reduce the risk of fire and electric shock due to 

internal component damage, use only  
Rug Doctor

®

 cleaning products intended for use 

with this appliance. See Cleaning Safety on page 3. 

WARNING! To reduce the risk of electric shock, 
use indoors only.

•  Do not leave machine unattended when plugged 

in or powered on. Unplug the machine when not in 
use and before cleaning or servicing.

•  Do not use if under the influence of alcohol or 

drugs. 

•  Do not immerse. Use only on surfaces moistened 

by cleaning process or small spills. Do not place 
machine in standing water or try to clear flooded 

areas.

•  Do not use machine as a vacuum. 

•  This machine is designed to clean normally soiled 

carpets in one cleaning pass, except berber  

multi-level or looped carpets. 

•  Do not use more than two cleaning passes on any 

area of carpet. Over-wetting and damage could 
include permanent staining of carpet.

•  Use caution when using hot tap water. Do not boil 

or microwave water to be used in this machine. 

•  Do not allow the machine to run dry. When the 

solution tank runs out, stop using and follow 
directions to refill.

•  Machine must not be used as a toy. Pay close 

attention when used near children or animals. This 
machine is not intended to be used by children 
under the age of 18. 

•  Do not allow children or pets to place their body 

parts in or near openings or moving parts. 

•  Do not use with damaged cord, plug or 

attachment. If this machine is not working properly, 
has been dropped, damaged, left outdoors, 

rained on or immersed in water, do not use and 
immediately contact Uline Customer Service at 

1-800-295-5510. 

•  Do not pull by the cord. Do not carry machine by 

the cord, use the cord as a handle, close a door 
on the cord or pull the cord around sharp edges or 
corners. Do not run machine over cord. Keep cord 
away from heated surfaces. 

•  Do not unplug by pulling on the cord. Unplug by 

pulling on the plug.

•  Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the machine.

•  Do not handle the plug or machine with wet or 

sweaty hands. 

•  Do not put any objects into the opening. Do not 

use the machine if any opening is blocked. Keep 
openings free of dust, lint, hair and anything that 

could reduce air flow. 

•  Keep hair, loose clothing, fingers and all parts of 

the body away from openings and moving parts.

Summary of Contents for RUG DOCTOR H-10972

Page 1: ...clude permanent staining of carpet Use caution when using hot tap water Do not boil or microwave water to be used in this machine Do not allow the machine to run dry When the solution tank runs out st...

Page 2: ...reproductive harm Connect to properly grounded outlet only See Grounding Instructions on page 3 WARNING Machine may contain water For best cleaning results and to avoid the risk of permanent damage to...

Page 3: ...to chemicals including Diethylhexyl Phthalate DEHP lead and other chemicals known to the state of California to cause cancer birth defects or possible reproductive harm For a complete list of warning...

Page 4: ...looped carpets retain more liquid For these types of carpets do not repeat cleaning passes If additional cleaning is desired allow carpets to dry before attempting to reclean heavily soiled areas Bec...

Page 5: ...tor Oxy Cleaning solution by pouring through the white filter screen Machine is full when liquid halfway covers the filter screen See Figure 5 5 Replace recovery tank and close the dome hood 6 Plug in...

Page 6: ...hly vacuuming or brushing When cleaning and drying cushions first spread sheets or towels on the floor as a drying surface for the dampened cushions 2 Disconnect the large vacuum hose Reconnect the to...

Page 7: ...h Section After each use unplug the machine from power source and use your finger or an old comb to remove any debris from the vibrating brush If you used any Rug Doctor attachments also remove debris...

Page 8: ...s lost vacuum pressure Ensure the dome hood is closed and securely sealed Check the hose connection at the back of the machine and secure if necessary Clean the filter that is in the dome Remove any a...

Page 9: ...e tip and blow air through it to remove any build up that may be clogging the tip Reattach the tip with the nut driver Ensure to position the tip opening so that it sprays side to side Check the lower...

Reviews: