Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
Electrical
SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended
receptacle location.
Door Swing
Units have a zero clearance for the door to open 90
o
, when
installed adjacent to cabinets.
Stainless steel models require 2-1/8” (54 mm) door
clearance to accommodate the handle if installed next to a
wall.
CAUTION
!
5
1/4" Min.
Wall
21"
Wall
21"
16-1/2"
16-1/2"
2" Min.
90°
Door Swing
90°
Door Swing
Black and White Models
2115R Models
Stainless Models
Wall
Wall
21"
16-1/2"
2" Min.
90°
Door Swing
Stainless Steel
21"
16-1/2"
90°
Door Swing
Black, White and Wood Overlay
1/4" Min.
2115WC Models
Wall
Wall
90°
Door Swing
Integrated
Stainless Steel, Black and White
90°
Door Swing
2175R(F) & 2275WC Models
90°
Door Swing
Wall
Wall
21"
25-1/2"
90°
Door Swing
21"
25-1/2"
Stainless Steel
Wood Overlay
2175BEV
90
°
Door Swing
Wall
Wall
90°
Door Swing
Stainless Steel
2175WC Models
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
Black, White and Integrated