background image

PAGE 1 OF 9 

0621 IH-7272

H-7272

WET LOCATION EXIT SIGN

1-800-295-5510

uline.com

CONDUIT ENTRY

1.  Drill a 3/4" hole through the desired conduit entry 

knockout located on the top or side of the frame of 

the sign. 

2.  Route the AC input conduit into frame. 

NOTE: All conduit connections must be UL listed 
and suitable for wet location parts.

3.  To install exit sign, refer to wall, ceiling or end 

mounting instructions on pages 2-3. 

WARNING! Risk of electric shock. Never 
connect to, disconnect from or service while 
equipment is energized. 

WARNING! Failure to follow these instructions 
and warnings may result in death, serious injury or 
significant property damage. For your protection, 
read and follow these instructions carefully 
before installing or maintaining this equipment. 

NOTE: These instructions do not attempt to cover 

all installation and maintenance situations.

•  All service shall be performed by qualified 

service personnel. This product must be 
installed and maintained in accordance with 
the applicable installation codes by a person 
familiar with the operation of the product and 
the hazards involved. 

•  This product must be installed in accordance with 

applicable installation codes and ordinances. 

•  Before wiring to power supply, turn off electricity 

at fuse or circuit breaker. 

•  Disconnect AC power and unplug battery 

before servicing. 

•  Consult your local building code for approved 

wiring and installation. 

•  May be used outdoors under cover (-4º to 158ºF)

•  Do not let power supply cord touch hot surfaces. 

• Do not mount near gas or electric heater. 

•  Equipment should be mounted in locations and 

at heights where it will not readily be subjected 
to tampering by unauthorized personnel. 

•  The use of accessory equipment not 

recommended by manufacturer may cause 

an unsafe condition. 

•  Do not use this equipment for other than 

intended use. 

•  The AC voltage rating of this equipment 

is specified on the product label. Do not 

connect equipment to any other voltage.

SAFETY

TOOLS NEEDED

Phillips Screwdriver

Drill

3/4" Drill Bit

Flathead Screwdriver

INSTALLATION

Figure 1

Para Español, vea páginas 4-6.

Pour le français, consulter les pages 7-9.

Summary of Contents for H-7272

Page 1: ...aintained in accordance with the applicable installation codes by a person familiar with the operation of the product and the hazards involved This product must be installed in accordance with applica...

Page 2: ...kplate for supply wire leads 5 Remove backing from self adhesive junction box gasket and adhere to backplate 6 Route input wires through center holes of backplate and make wiring connection For 120V u...

Page 3: ...ocked onto the wall tightly Distance between bracket and wall should be less than 2 mm See Figures 11 12 17 Apply continuous AC power and press test button to check operation Figure 12 Push MAINTENANC...

Page 4: ...ebe instalarse y recibir mantenimientos de acuerdo a los c digos de instalaci n aplicables por alguien familiarizado con el funcionamiento del producto y los peligros que conlleva Este producto debe i...

Page 5: ...es de suministro 5 Retire el respaldo de la junta autoadhesiva de la caja de conexiones y adhi rala a la placa posterior 6 Gu e los cables de entrada a trav s de los orificios de la placa posterior y...

Page 6: ...d est bien asegurada a la pared La distancia entre el soporte y la pared deber a ser de menos de 2 mm Vea Diagramas 11 12 17 Aplique electricidad CA continua y presione el bot n de test para verificar...

Page 7: ...ions d installation et d entretien L entretien de cet quipement doit tre effectu uniquement par un personnel de maintenance qualifi Cet quipement doit tre install et entretenu conform ment aux codes d...

Page 8: ...de la plaque arri re pour les fils conducteurs 5 Retirez la doublure du joint du bo tier de jonction puis collez le joint la plaque arri re 6 Acheminez les fils d entr e travers les trous au centre d...

Page 9: ...l unit pour vous assurer qu elle est bien s curis e au mur La distance entre le support et le mur doit tre moins de 2 mm Voir Figures 11 et 12 17 Fournissez une alimentation CA continue et appuyez su...

Reviews: