OPERATING ISSUE
RECOMMENDATIONS
Belts continue to break.
1. The agitator bar should be positioned so the belt lines up
with the grooves on the bottom frame of the vacuum.
2. Ensure that vacuum is set to correct carpet height setting.
If there is little or no suction.
1. There may be a clog in the hose. Take the hose apart at
the top and bottom and remove the clog.
2. Clean or replace the HEPA filter assembly and/or
pre-motor filter.
3. Ensure that vacuum is set to correct carpet height setting.
4. Check suction control valve to ensure it is set correctly.
Can be set to Hose or Floor Cleaning.
Vacuum turns off while in use.
1. The machine may turn off due to overheating.
2. Check to make sure nothing is caught on the brush roll
and check for clogs.
3. You will need to press the reset button to restart the brush.
Vacuum has a burning smell.
1. The belt may be damaged or something may be caught
in the brush roll.
2. Check brush roll for obstruction.
3. Replace belt.
Brushes aren't turning.
1. Check suction control valve to ensure that it is turned to
floor cleaning.
2. Make sure vacuum is lowered into cleaning position. (Will
not spin in upright storage position.)