7. Remove four screws from junction box faceplate with
Phillips screwdriver. Remove faceplate. (See Figure 7)
8. Take photo of termination block wire pattern. Use a
3 mm flathead screwdriver to loosen screws holding
colored wires. (See Figure 7)
IMPORTANT! Termination block screws only
need one full turn to release wires.
9. Gently remove colored wires from termination block.
(See Figure 8)
10. Unscrew cord grip cap connecting main cable to
junction box. (See Figure 9)
11. Cut cable tie and unbundle main cable from
circular magnet. Pull main cable through hole
at top of indicator housing to remove.
INSTALLATION
1. Insert main cable through hole at top of
indicator housing. (See Figure 10)
2. Wrap main cable around circular magnet three
times. Slide cord grip cap onto end of main cable.
(See Figure 11)
3. Feed main cable through cord grip on junction box.
(See Figure 12)
INSTRUCTIONS CONTINUED
Figure 7
Figure 9
Figure 10
Figure 11
Figure 12
Figure 8
Termination Block
Cord Grip