![U-Line H-161 Manual Download Page 4](http://html1.mh-extra.com/html/u-line/h-161/h-161_manual_3133124004.webp)
PAGE 4 OF 18
1022 IH-161
MODEL
SOURCE
IMPULSE
POWER
MAX. SEAL
LENGTH
MAX. SEAL
THICKNESS
WEIGHT
DIMENSIONS
H-458
120 V
160 W
4"
8 Mil
3.7 lbs.
2.8 x 8.3 x 5.9"
H-161
120 V
410 W
8"
8 Mil
7.7 lbs.
3.2 x 15 x 6.3"
H-163
120 V
410 W
8"
8 Mil
5.8 lbs.
3.2 x 12.6 x 5.9"
H-190
120 V
580 W
12"
8 Mil
8.5 lbs.
3.3 x 17.8 x 7.4"
H-293
120 V
580 W
12"
8 Mil
10.1 lbs.
3.2 x 17.9 x 7.4"
H-306
120 V
670 W
16"
8 Mil
9.9 lbs.
3 x 21 x 7"
H-963
120 V
670 W
16"
8 Mil
11.9 lbs.
3.2 x 21.8 x 7.3"
H-1029
120 V
870 W
20"
8 Mil
13 lbs.
4.5 x 28 x 7.8"
H-1252
120 V
870 W
20"
8 Mil
13 lbs.
3.2 x 25.9 x 7.4"
SEALER SPECIFICATIONS
SPECIFICATIONS CONTINUED
OPERATING ISSUE
RECOMMENDATIONS
Sealer stops sealing and the sealing light does not
come on.
The arm may not be activating the microswitch.
1. Unplug unit.
2. Unscrew rubber foot screws to remove bottom.
3. Turn sealer upside down, and press down to see
if activation screw extends to activate black
microswitch button. You should hear a
"
click
"
(see photo).
4. If it does not
"
click
"
, extend activation screw
approximately 1/16 to 1/8
"
.
5. Continue to adjust and test until you hear a
"
click
"
.
TROUBLESHOOTING
TIPS:
• Always keep sealing platform clean. Do not use water
to clean sealing platform.
• Only use ULINE replacement parts and service kits.
• A short circuit will occur if the bottom teflon cloth strip
wears out. Check the bottom teflon tape for wear
and damage when replacing heating element or top
teflon cover.
• A worn rubber pressure pad (under the handle) will
influence the quality of the seals. The rubber pad
should be periodically checked for uneven wear.
• If the bag seal is damaged or broken, it is because
the heating time is too long. Reset the timer knob to a
lower number. Reference Settings Chart on page 3.
• If the plastic bag sticks to the sealing arm, it is
because there was not enough cooling time. Keep
the arm down for a longer period of time after the
light turns off.
FOR FURTHER ASSISTANCE, PLEASE CALL ULINE CUSTOMER
SERVICE AT 1-800-295-5510.