PAGE 6 OF 30
0917 IH-1030
OPERATING INSTRUCTIONS CONTINUED
CLEARING A JAM
1. Disconnect air supply.
2. Pull up lever. (See FIgure 11)
PROBLEM
CAUSE
REMEDY
Air leak from trigger
O-ring on valve or on tube is
damaged.
Replace O-ring.
Air leak from exhaust
port
O-Ring on valve or on tube is
damaged.
O-Ring on piston is damaged.
Replace O-ring.
Air leak from cylinder
Piston rod port O-ring is damaged.
Replace O-ring.
Slow & short travel
cycling
Check for loose screw or wear of
parts.
1. Position eccentric pin and tighten screw.
2. Recheck for maximum efficiency.
a. Adjust pin slightly upward if due to short travel.
b. Adjust pin slightly downward if due to slow cycling.
Excessive jams
1. Slow & short travel cycle.
2. Teeth screws are loose.
3. Wrong staple size.
4. Insufficient lubrication.
1. Adjust as noted above.
2. Tighten screws.
3. Check staples.
4. Clean and lubricate.
Uneven clinch
Wrong staple size.
Check for proper leg length adjustment and
clincher size.
Unclinched staple
1. Teeth are loose or broken.
2. Slow & short travel cycle.
1. Check & replace teeth as needed.
2. Adjust as noted above.
3. Insert needle nose pliers or screw driver to clear jam.
(See Figure 11)
4. Push down lever.
WARNING
Stop using the stapler immediately if any of the following problems occur.
Serious personal injury could occur. Any repairs or replacements must be done
by a qualified person or authorized service center only.
TROUBLESHOOTING
Figure 11