LEON-G100 / LEON-G200 - System Integration Manual
GSM.G1-HW-09002-G3
Preliminary
Product Testing
Page 118 of 125
To avoid module damage during transmitter test when good antenna termination is not
guaranteed, use a low PCL level (max 15). u-blox assumes no responsibilities for module
damaging caused by an inappropriate use of this feature.
2.
Trigger TX burst at maximum PCL:
o
To check if the power supply is correctly assembled and is able to deliver the required current
3.
Trigger TX burst:
o
To measure current consumption
4.
Trigger RX measurement:
o
To test receiver signal level. If no losses between
ANT
pin and input power source are assumed, the
estimated module power level can vary approximately within 3GPP tolerances for the average value
o
To check if module was damaged during soldering process or during handling (ESD, mechanical
shock…)
5.
Trigger TX burst and RX measurement to check:
o
Overall RF performance of the device including antenna measuring TX and RX power levels