C099-F9P - User Guide
UBX-18055649 - R02
Firmware updates
Page 32 of 48
Figure 50: s-center select ODIN-W2 firmware, Normal mode, COM port, baud rate
Select the ODIN-W2 Firmware folder and ODIN-W26X_Firmware bin file. Do not select a Boot image.
Ensure the set COM port and baud rate is correct.
Click the Update button. It will show programming of firmware and exit when completed.
After this the device baud rate is set to 115200 with hardware flow control enabled. This requires
changing to No hardware flow control. First set up s-center to 115200 baud and no flow control. Then
open the port. Then click EVK-ODIN-W2 via ST-LINK button shown below.
Figure 51: Resetting ODIN-W2 to no flow control
Click the AT mode button to ensure it is responding correctly. You will see it respond with AT
commands if communication is ok.
Figure 52: Clicking AT Mode button