Stage II – testing door, trunk and bonnet switches (LED periodically blinks 2x)
•
Triggering any of these inputs (e.g. opening of door) is signalled by single chirp of siren.
•
If there is only one input triggered, release of that input (e.g. closing the door) is not signalled.
•
If more then one input is triggered (e.g door and trunk ), releasing that input (e.g closing door) is also
signalled by single siren chirp.
in order to go to stage III, press and hold the PA button (aprox. 3 seconds) until siren chirps 3x.
Stage III
– testing additional sensor (LED blinks 3x)
•
Triggering additional sensors (e.g. shock sensor) connected to front and rear sensor sockets is signalled
by single chirp of siren.
•
If there is only one input triggered, release of that input is not signalled.
•
If more then one input is triggered releasing that input is also signalled by single siren chirp.
In order to go to stage III, press and hold the PA button (aprox. 3 seconds) until siren chirps 4x.
Stage IV – setting sensitivity and testing of internal ultrasonic motion detector
•
Detection of movement inside car is signalled by series of short siren chirps.
•
The LED displays the current setting of sensitivity as a number of blinks (1-8).
•
Short press of PA changes the sensitivity of internal ultrasonic motion detector (8 levels) in a sequence
(1-2-3-4-5-6-7-8 -1-2-3-4...).
After setting / testing ultrasonic motion detector, the service mode should be left by switching off the ignition,
if the user did not want to erase / program / test
Tytan
remotes nor the RF module was not installed.
Otherwise, press and hold the PA button for 3 seconds until siren chirps / LED blinks 5 times
Stage V - testing and/or erasing/programming new remotes
5.1.
After releasing PA button, the LED lights up for 8 seconds.
•
W
ait 8 seconds the programming is skipped. Transmitters
are not
erased from memory and the
VSS enters the transmitter testing mode (5.3).
•
Press the PA 5 times when the LED is lit - the previously stored remotes are erased from memory - the VSS
enters the remote programming mode.
tytan ds410 can
15