Doc

 

No.

 

FM0600

 

issue

 

H1

 

Page

 

3

 

 

Door Frame

Door

2.

 

HOW

 

TO

 

INSTALL

 

A

 

BED

 

SENSOR

 

 

The

 

Bed

 

Sensor

 

must

 

be

 

placed

 

between

 

the

 

bed

 

base

 

and

 

the

 

mattress.

 

 

Check

 

the

 

base

 

is

 

in

 

reasonable

 

condition

 

with

 

a

 

flat

 

firm

 

surface

 

to

 

lay

 

the

 

sensor

 

on.

 

 

The

 

sensor

 

should

 

be

 

placed

 

across

 

the

 

width

 

of

 

the

 

bed

 

at

 

a

 

point

 

where

 

the

  

hips

 

of

 

the

 

person

 

will

 

be

 

when

 

lying

 

down.

 

Ensure

 

the

 

connecting

 

cable

  

exits

 

safely

 

without

 

causing

 

a

 

trip

 

hazard.

  

 

Plug

 

the

 

lead

 

into

 

the

 

sensor

 

controller.

 

 

Spare

 

Bed

 

Sensor

 

with

 

2m

 

Lead:

 

Product

 

Code

 

ZCS844

 

Dimensions:

 

650mm

 

x

 

130mm

 

x

 

10mm

 

(LxWxD)

 

RJ45

 

Double

 

Adapter

 

(used

 

to

 

connect

 

2

 

bed

 

sensors):

 

Product

 

Code

 

P10285

 

 

 
 

3.

 

HOW

 

TO

 

INSTALL

 

A

 

CHAIR

 

SENSOR

 

 

The

 

Chair

 

Sensor

 

must

 

be

 

placed

 

between

 

the

 

seat

 

base

 

and

 

the

 

cushion.

 

 

Check

 

the

 

base

 

is

 

in

 

reasonable

 

condition

 

with

 

a

 

flat

 

firm

 

surface

 

to

 

lay

 

the

 

sensor

 

on.

 

 

The

 

sensor

 

should

 

be

 

placed

 

across

 

the

 

width

 

of

 

the

 

chair

 

at

 

a

 

point

 

where

 

the

 

person

 

will

 

be

 

sitting.

 

Ensure

 

the

 

connecting

 

cable

 

exits

 

safely

 

without

 

causing

 

a

 

trip

 

hazard.

  

 

Plug

 

the

 

lead

 

into

 

the

 

sensor

 

controller.

 

 

Spare

 

Chair

 

Sensor

 

with

 

2m

 

Lead:

 

Product

 

Code

 

ZCS859

 

Dimensions:

 

325mm

 

x

 

130mm

 

x

 

10mm

 

(LxWxD)

 

RJ45

 

Double

 

Adapter

 

(used

 

to

 

connect

 

2

 

chair

 

sensors):

 

Product

 

Code

 

P10285

 

 

 
 

4.

 

HOW

 

TO

 

INSTALL

 

A

 

PRESSURE

 

MAT

 

 

The

 

Pressure

 

Mat

 

must

 

be

 

placed

 

under

 

the

 

carpet

 

or

 

a

 

rug

 

alongside

 

the

 

bed

 

so

 

it

 

will

 

be

 

stood

 

on

 

when

  

the

 

person

 

gets

 

out

 

of

 

bed.

  

 

The

 

mat

 

should

 

be

 

placed

 

so

 

the

 

connecting

 

cable

 

exits

  

safely

 

without

 

causing

 

a

 

trip

 

hazard.

  

 

Plug

 

the

 

lead

 

into

 

the

 

sensor

 

controller.

 

 

Pressure

 

Mat

 

with

 

2m

 

lead

 

is

 

ordered

 

separately:

 

Product

 

Code

 

ZCS857

 

Dimensions:

 

520mm

 

x

 

400mm

 

x

 

6mm

 

(LxWxD)

 

RJ45

 

Double

 

Adapter

 

(used

 

to

 

connect

 

2

 

pressure

 

mats):

 

Product

 

Code

 

P10285

 

 
 

5.

 

HOW

 

TO

 

INSTALL

 

DOOR

 

CONTACTS

 

 

The

 

Door

 

Contacts

 

should

 

be

 

installed

 

by

 

a

  

competent

 

person

 

on

 

the

 

frame

  

of

 

the

 

door

 

being

 

monitored.

  

 

Fix

 

the

 

contact

 

(part

 

with

 

wire

 

connected)

 

to

 

the

 

door

 

frame.

 

Clip

 

the

 

cable

 

to

 

the

  

door

 

frame

 

and

 

route

 

safely

 

without

  

causing

 

a

 

trip

 

hazard.

  

 

Fix

 

the

 

magnet

 

to

 

the

 

door.

 

There

 

should

 

be

 

no

 

more

 

than

 

10mm

 

between

 

the

    

    

              

Magnet

 

2

 

parts

 

when

 

the

 

door

 

is

 

closed.

 

 

 

              

 

Plug

 

the

 

lead

 

into

 

the

 

sensor

 

controller.

  

 

 

Door

 

Contact

 

with

 

2m

 

lead

 

is

 

ordered

 

separately:

 

Product

 

Code

 

ZCS854

 

RJ45

 

Double

 

Adapter

 

(used

 

to

 

connect

 

2

 

door

 

contacts):

 

Product

 

Code

 

P10285

 

 

 
 
 

 

Cable to Sensor Controller

Summary of Contents for ZXT473

Page 1: ...then an optional 1 to 99 minute programmable reset period can be set If the person is not detected back in their bed chair at the end of this period then an alarm will be raised again Monitoring star...

Page 2: ...CONTROLLER The sensor controller includes a power lead and a rechargeable battery depending on the package it may also be supplied with either a bed sensor or a chair sensor Alternative bed chair sen...

Page 3: ...Spare Chair Sensor with 2m Lead Product Code ZCS859 Dimensions 325mm x 130mm x 10mm LxWxD RJ45 Double Adapter used to connect 2 chair sensors Product Code P10285 4 HOW TO INSTALL A PRESSURE MAT The Pr...

Page 4: ...st be placed on top of the mattress below the sheet See the placement options printed on the Bed Sensor Ensure the connecting cable exits safely without causing a trip hazard Plug the lead into the se...

Page 5: ...another sub menu or give you the option to change settings Use the keys to increase decrease the setting highlighted by the cursor Use the keys to move the cursor back forwards between fields To retu...

Page 6: ...ll end at the end of the monitoring period If you choose Yes the display will change to Still in Bed Alarm How Long 000 Mins Use the keys to set the still in bed alarm from 0 to 999 minutes then press...

Page 7: ...actory Setup Exit Select Calibrate and Test then press ENTER Calibrate and Test Calibrate Sensor View In Out States Change Sensitivity Calibrate and Test Test Mode Exit Calibrate Sensor place the bed...

Page 8: ...up Exit Load Defaults and Apply to restore factory settings as below Date 01 01 00 Time 00 00 with Auto BST on Sensor type un calibrated bed sensor On all the time No Active start stop time periods al...

Page 9: ...digit ID is made up of the 2 digit sensor type code e g bed sensor 33 chair sensor 38 or door exit 34 followed by the 6 digit unit ID which can be found on a label on the back of the sensor controlle...

Page 10: ...Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for m...

Page 11: ...o FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Press the CARER CALL button The display will show the Sensor Type and the sensor controller...

Page 12: ...eleted from the Delete Telecare Device pull down list box prefixed with a T33 34 38 Details of the Sensor Controller selected will be displayed in the Room House Code and ID boxes below If the details...

Page 13: ...Nursecall system When the sensor controller is in its normal operating mode the key is used to send a CARER CALL Press this key once and the display will show Unit is sending a CARER CALL alarm PLEAS...

Reviews: