Tynetec ZXT473 Manual Download Page 2

Doc

 

No.

 

FM0600

 

issue

 

H1

 

Page

 

2

 

 

CONTENTS

 

 

 

Section

 

Topic

 

Page

 

1

 

How

 

to

 

connect

 

the

 

Sensor

 

Controller

 

2

 

2

 

How

 

to

 

install

 

a

 

Bed

 

Sensor

 

3

 

3

 

How

 

to

 

install

 

a

 

Chair

 

Sensor

3

 

4

 

How

 

to

 

install

 

a

 

Pressure

 

Mat

 

3

 

5

 

How

 

to

 

install

 

Door

 

Contacts

 

3

 

6

 

How

 

to

 

install

 

a

 

Magic

 

Stick

 

Bed

 

Sensor

4

 

7

 

How

 

to

 

install

 

a

 

Magic

 

Stick

 

Chair

 

Sensor

 

4

 

8

 

How

 

to

 

install

 

a

 

SensAlert

 

Over

Mattress

 

Bed

 

Sensor

 

4

 

9

 

How

 

to

 

install

 

a

 

SensAlert

 

Over

Cushion

 

Chair Sensor

4

 

10

 

How

 

to

 

switch

 

the

 

Sensor

 

Controller

 

ON/OFF

 

5

 

11

 

Low

 

Battery

 

Warning

 

5

 

12

 

Navigating

 

the

 

Display

 

Menu’s

 

5

 

13

 

Quick

 

Setup

 

Mode

 

5

 

14

 

Advanced

 

Setup

 

Mode

 

7

 

15

 

Registration

 

Mode

 

8

 

16

 

Registering

 

a

 

Sensor

 

Controller

 

onto

 

a

 

Reach

 

At

home

 

Alarm

 

9

 

17

 

Registering

 

a

 

Sensor

 

Controller

 

onto

 

an

 

Advent

 

xt

 

Warden

 

Call

  

10

 

18

 

Registering

 

a

 

Sensor

 

Controller

 

onto

 

an

 

Altec

 

Response Carer

 

Alarm

11

 

19

 

Registering

 

a

 

Sensor

 

Controller

 

onto

 

a

 

Touchsafe

 

Pro

 

Nursecall

 

12

 

20

 

Home/Away

 

Mode

 

13

 

21

 

Carer

 

Call

 

Facility

 

13

 

22

 

Optional

 

Pear

 

Push

 

13

 

 

 
 

1.

 

HOW

 

TO

 

CONNECT

 

THE

 

SENSOR

 

CONTROLLER

 

The

 

sensor

 

controller

 

includes

 

a

 

power

 

lead

 

and

 

a

 

rechargeable

 

battery,

 

depending

 

on

 

the

 

package

 

it

 

may

 

also

 

be

 

supplied

 

with

 

either

 

a

 

bed

 

sensor

 

or

 

a

 

chair

 

sensor.

 

Alternative

 

bed/chair

 

sensors,

 

pressure

 

mat,

 

door

 

contacts

 

and

 

double

 

adapter

 

are

 

available

 

separately.

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.

 

The

 

sensor

 

controller

 

should

 

be

 

within

 

3

 

metres

 

of

 

a

 

mains

 

supply,

 

if

 

an

 

extension

 

cable

 

is

 

necessary

 

care

 

should

 

be

 

taken

 

to

  

 

ensure

 

that

 

no

 

one

 

can

 

trip

 

over

 

the

 

power

 

lead.

 

 

2.

 

Slide

 

the

 

battery

 

compartment

 

open

 

on

 

the

 

rear

 

of

 

the

 

sensor

 

controller

 

and

 

connect

 

the

 

RECHARGEABLE

 

BATTERY

.

  

 

3.

 

Plug

 

the

 

POWER

 

LEAD

 

into

 

the

 

POWER

 

SOCKET

 

and

 

connect

 

to

 

the

 

mains

 

supply.

 

 

4.

 

Plug

 

the

 

BED/CHAIR

 

SENSOR/MAGIC

 

STICK

 

or

 

PRESSURE

 

MAT

 

or

 

DOOR

 

CONTACT

 

into

 

the

 

SENSOR

 

SOCKET

.

 

 

5.

 

Note:

 

an

 

RJ45

 

DOUBLE

 

ADAPTER

 

can

 

be

 

used

 

to

 

connect

 

2

 

of

 

the

 

SAME

 

TYPE

 

sensors

 

into

 

the

 

SENSOR

 

SOCKET

.

 

 

6.

 

The

 

I/O

 

SOCKET

 

is

 

only

 

used

 

for

 

an

 

optional

 

Pear

 

Push

 

lead

 

or

 

to

 

connect

 

the

 

auxiliary

 

relay

 

output

  

 

    

STANDARD

 

BED

  

  

SENSOR

 

  

STANDARD

 

CHAIR

SENSOR

 

  

DOOR

 

CONTACT

PRESSURE

        

MAT

 

I/O

 

SOCKET

SENSOR

 

SOCKET

POWER

 

SOCKET

 

POWER

  

   

LEAD

 

SENSOR

 

  

CONTROLLER

RECHARGEABLE

   

BATTERY

RJ45 DOUBLE

  

ADAPTER

 

BED/CHAIR

 

MAGIC

   

     

STICK

 

OVER

MATTRESS

 

              

BED

 

SENSOR

OVER

CUSHION

  

     

CHAIR

 

SENSOR

 

Summary of Contents for ZXT473

Page 1: ...then an optional 1 to 99 minute programmable reset period can be set If the person is not detected back in their bed chair at the end of this period then an alarm will be raised again Monitoring star...

Page 2: ...CONTROLLER The sensor controller includes a power lead and a rechargeable battery depending on the package it may also be supplied with either a bed sensor or a chair sensor Alternative bed chair sen...

Page 3: ...Spare Chair Sensor with 2m Lead Product Code ZCS859 Dimensions 325mm x 130mm x 10mm LxWxD RJ45 Double Adapter used to connect 2 chair sensors Product Code P10285 4 HOW TO INSTALL A PRESSURE MAT The Pr...

Page 4: ...st be placed on top of the mattress below the sheet See the placement options printed on the Bed Sensor Ensure the connecting cable exits safely without causing a trip hazard Plug the lead into the se...

Page 5: ...another sub menu or give you the option to change settings Use the keys to increase decrease the setting highlighted by the cursor Use the keys to move the cursor back forwards between fields To retu...

Page 6: ...ll end at the end of the monitoring period If you choose Yes the display will change to Still in Bed Alarm How Long 000 Mins Use the keys to set the still in bed alarm from 0 to 999 minutes then press...

Page 7: ...actory Setup Exit Select Calibrate and Test then press ENTER Calibrate and Test Calibrate Sensor View In Out States Change Sensitivity Calibrate and Test Test Mode Exit Calibrate Sensor place the bed...

Page 8: ...up Exit Load Defaults and Apply to restore factory settings as below Date 01 01 00 Time 00 00 with Auto BST on Sensor type un calibrated bed sensor On all the time No Active start stop time periods al...

Page 9: ...digit ID is made up of the 2 digit sensor type code e g bed sensor 33 chair sensor 38 or door exit 34 followed by the 6 digit unit ID which can be found on a label on the back of the sensor controlle...

Page 10: ...Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for m...

Page 11: ...o FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Press the CARER CALL button The display will show the Sensor Type and the sensor controller...

Page 12: ...eleted from the Delete Telecare Device pull down list box prefixed with a T33 34 38 Details of the Sensor Controller selected will be displayed in the Room House Code and ID boxes below If the details...

Page 13: ...Nursecall system When the sensor controller is in its normal operating mode the key is used to send a CARER CALL Press this key once and the display will show Unit is sending a CARER CALL alarm PLEAS...

Reviews: