background image

Doc

 

No.

 

FM0462

 

issue

 

D

 

Page

 

5

  

Registering

 

an

 

Enuresis

 

Sensor

 

onto

 

an

 

Altec

 

Response

 

local

 

carer

 

alarm

 

unit

 

 

 

1.

 

Put

 

the

 

Altec

 

Response

 

unit

 

into

 

radio

 

device

 

learn

 

mode…

  

  

 

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

2.

 

Activate

 

the

 

Enuresis

 

sensor…

 

 

 

 

 

 

 

 

 

 

 

               

 
 

 

 

 

 

 

 

 

 

  

 
 
 

 

 
 
 

3.

 

Exit

 

the

 

Altec

 

Response

 

radio

 

device

 

learn

 

mode…

 

  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

4.

 

Activate

 

the

 

Enuresis

 

sensor

 

and

 

check

 

an

 

enuresis

 

alarm

 

call

 

is

 

displayed

 

on

 

the

 

Altec

 

Response

 

unit.

  

 

Deleting

 

an

 

Enuresis

 

Sensor

 

from

 

an

 

Altec

 

Response

 

local

 

carer

 

alarm

 

unit

 

 

Press

 

ENTER

 

to

 

activate

 

the

 

wake

up

 

display

 

then

 

ENTER

 

again

 

to

 

display

 

the

 

main

 

menu

 

Press

 

ENTER

 

to

 

select

 

 

Radio

 

Devices

 

  

Press

 

the

 

 

key

 

to

 

select

 

 

Delete

 

Device

 

 

then

 

press

 

ENTER

  

The

 

display

 

will

 

prompt

 

you

 

to

 

Trigger

 

the

 

Sensor

 

Activate

 

the

 

Enuresis

 

sensor

 

to

 

be

 

deleted

 ‐ 

the

 

display

 

will

 

show

 

the

 

device

 

type

 

and

 

its

 

8

 

digit

 

ID

 

number

 

If

 

this

 

is

 

the

 

device

 

you

 

activated

 

press

 

the

 

 

key

 

to

 

select

  

 

Delete

 

 

then

 

press

 

ENTER

 

If

 

it’s

 

NOT

 

the

 

device

 

you

 

activated

 

press

 

the

 

ENTER

 

key

 

to

 

select

 

 

Reject

 

 

then

 

try

 

again

 

To

 

exit

 

the

 

mode

 

select

 

 

Exit

 

 

then

 

press

 

the

 

ENTER

 

key.

 

 
 

 

 
 

Refer

 

to

 

the

 

Altec

 

Response

 

installation

 

guide

 

(Doc

 

No.

 

FM0548)

 

provided

 

with

 

the

 

portable

 

alarm

 

unit

 

for

 

more

 

information

 

on

 

programming

 

and

 

testing

 

radio

 

devices.

  

 
 

 

Place

 

a

 

damp

 

cloth

 

on

 

the

 

plastic

 

bed

 

mat

 

and

 

the

 

light

 

will

 

flash

 

RED

 

on

 

the

 

interface

 

unit.

 

 

The

 

display

 

will

 

show

 

Enuresis

 

and

 

the

 

Enuresis

 

sensor

 

8

 

digit

 

ID

 

number.

 

Check

 

the

 

ID

 

is

 

correct,

 

press

 

the

 

 

key

 

to

 

select

 

 

Accept

 

 

then

  

press

 

ENTER

.

 

Note:

 

if

 

another

 

device

 

has

 

been

 

picked

up

 

press

 

ENTER

  

to

 

 

Reject

 

 

and

 

try

 

again

.

 

 

The

 

display

 

will

 

show

 

 

Flat

 

,

 

use

 

the

 

 

&

 

 

keys

 

to

 

choose

 

the

  

dwelling

 

type.

  

Press

 

the

 

 

key

 

to

 

select

 

 

No:

 

000000

 

 

then

 

press

 

the

 

ENTER

 

key.

  

Use

 

the

 

 

&

 

 

keys

 

to

 

select

 

each

 

digit

 

of

 

the

 

flat

 

number

 

and

  

the

 

 

&

 

 

keys

 

to

 

move

 

between

 

digits

 

then

 

press

 

the

 

ENTER

 

key.

 

Press

 

 

key

 

several

 

times

 

to

 

select

 

 

Exit

 

 

then

 

press

 

the

 

ENTER

 

key.

  

The

 

display

 

will

 

prompt

 

you

 

to

 

Trigger

 

the

 

Sensor

 

again.

 

 

*Note:

 

if

 

the

 

Enuresis

 

sensor

 

has

 

been

 

activated

 

in

 

the

 

last

 

15

 

minutes

 

you’ll

 

have

 

to

 

reset

 

the

 

MASK

 

TIME

 

 

see

 

page

 

2.

 

Press

 

ENTER

 

to

 

activate

 

the

 

wake

up

 

display

 

then

 

ENTER

 

again

 

to

 

display

  

the

 

main

 

menu.

 

 

Press

 

ENTER

 

to

 

select

 

 

Radio

 

Devices

 

  

 

Press

 

ENTER

 

to

 

select

 

 

Learn

 

Device

 

  

 

The

 

display

 

will

 

prompt

 

you

 

to

 

Trigger

 

the

 

Sensor

”.

 

 

You

 

now

 

have

 

20

 

seconds

 

to

 

activate

 

the

 

Enuresis

 

sensor.

 

tynetec 

tynetec 

*Note:

 

if

 

the

 

Enuresis

 

sensor

 

has

 

been

 

activated

 

in

 

the

 

last

 

15

 

minutes

 

you’ll

 

have

 

to

 

reset

 

the

 

MASK

 

TIME

 

 

see

 

page

 

2.

 

 

From

 

the

 

Learn

 

Device

 

menu

 

select

 

 

Exit

 

 

then

 

press

 

ENTER

.

  

 

From

 

the

 

Radio

 

Devices

 

menu

 

select

 

 

Exit

 

 

then

 

press

 

ENTER

.

 

 

The

 

display

 

will

 

return

 

to

 

the

 

wake

up

 

screen

 

and

 

go

 

blank

 

after

 

10

 

seconds.

 

 

The

 

Altec

 

Response

 

is

 

now

 

back

 

in

 

normal

 

operating

 

mode.

 

 

Summary of Contents for W00369

Page 1: ...de up text on the mat shows THIS SIDE UP 3 If necessary secure the mat with cord through the 4 corner tie down points 4 Ensure the wire exits safely without causing a hazard 5 Place a bath towel over the top of the bed mat for best performance Be aware that nylon or polyester sheets can give false alarms 6 Refit the bottom bed sheet 7 Plug the lead into the interface unit and make sure it is place...

Page 2: ...he bed mat from the interface unit before cleaning The bed mat can be wiped clean with a damp cloth and soapy water or a mild disinfectant Do not fully submerge the bed mat lead or interface unit in water Replacement Bed Mats Due to the nature of the product bed mats are non returnable Replacement mats are available separately order Tynetec Part No W00369 Battery Life The battery is checked once a...

Page 3: ...ght will return to STEADY GREEN The 8 digit ID can be found on a label on the back of the Enuresis interface unit it will always start with 32xxxxxx The instructions given above for the standard Reach product also applies to the Reach Plus Reach Plus GSM and Reach Ultra models Refer to the instruction booklets provided with these products for more information on programming and testing radio devic...

Page 4: ...ion Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for more information on programming and testing radio devices Using the Manager s DECT telephone Press the LINE key and wait for the Ready prompt Enter 5 0 0 0 followed by the key Enter the flat number the Enuresis sensor is being installed in followed by the key You now have 1 minute to activate the Enu...

Page 5: ...and the light will flash RED on the interface unit The display will show Enuresis and the Enuresis sensor 8 digit ID number Check the ID is correct press the key to select Accept then press ENTER Note if another device has been picked up press ENTER to Reject and try again The display will show Flat use the keys to choose the dwelling type Press the key to select No 000000 then press the ENTER key...

Page 6: ...a T32 Details of the Enuresis sensor selected will be displayed in the Room House Code and ID boxes below If the details shown are correct press the Delete button Press the Close button to exit Refer to the Touchsafe Pro Display Panel user guide Doc No FM5505 provided with the Nursecall system for more information Tynetec and Aidcall operate a policy of continuous improvement and reserve the right...

Reviews: