background image

Doc

 

No.

 

FM0462

 

issue

 

D

 

Page

 

4

  

Registering

 

an

 

Enuresis

 

Sensor

 

onto

 

an

 

Advent

 

xt

 

warden

 

call

 

system

 

 

1.

 

Put

 

the

 

Advent

 

xt

 

system

 

into

 

radio

 

device

 

learn

 

mode…

  

  

  

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

2.

 

Activate

 

the

 

Enuresis

 

sensor…

 

 

 

 

 

 

 

 

 

 

 

               

 
 

 

 

 

 

 

 

 

 

  

 
 
 

  

3.

 

Exit

 

the

 

Advent

 

xt

 

system

 

radio

 

device

 

learn

 

mode…

 

  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

4.

 

Activate

 

the

 

Enuresis

 

sensor

 

and

 

check

 

an

 

Enuresis

 

alarm

 

call

 

is

 

reported

 

on

 

the

 

warden

 

call

 

system.

  

 

 

Deleting

 

an

 

Enuresis

 

Sensor

 

from

 

an

 

Advent

 

xt

 

warden

 

call

 

system

 

 

Press

 

the

 

LINE

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt.

 

Enter

 

5

 

0

 

0

 

1

 

followed

 

by

 

the

 

 

key.

 

Enter

 

the

 

flat

 

number

 

the

 

Enuresis

 

sensor

 

is

 

being

 

deleted

 

from

 

followed

 

by

 

the

 

 

key.

 

Activate

 

the

 

Enuresis

 

sensor

 

to

 

be

 

deleted.

 

Wait

 

for

 

the

 

Pendant

 

Disabled

 

 

Enter

 

Flat

 

prompt.

 

Press

 

the

 

#

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt,

 

then

 

press

 

the

 

LINE

 

key

 

to

 

clear

 

the

 

connection.

 

 
 
 

 

 
 

Refer

 

to

 

the

 

Advent

 

xt

 

operators

 

manual

 

(Doc

 

No.

 

FM0420)

 

provided

 

with

 

the

 

warden

 

call

 

system

 

for

 

more

 

information

 

on

 

programming

 

and

 

testing

 

radio

 

devices.

  

 
 

 
 
 
 

 

Using

 

the

 

Manager’s

 

DECT

 

telephone;

 

 

Press

 

the

 

LINE

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt.

 

 

Enter

 

5

 

0

 

0

 

0

 

followed

 

by

 

the

 

 

key.

 

 

Enter

 

the

 

flat

 

number

 

the

 

Enuresis

 

sensor

 

is

 

being

 

installed

 

in

 

followed

 

by

 

the

 

 

key.

 

 

You

 

now

 

have

 

1

 

minute

 

to

 

activate

 

the

 

Enuresis

 

sensor.

 

 

Ready”

 

Using

 

the

 

Manager’s

 

DECT

 

telephone;

 

 

Press

 

the

 

#

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt.

 

 

Press

 

the

 

LINE

 

key

 

to

 

clear

 

the

 

connection

 

and

 

the

 

warden

 

call

 

system

 

is

 

now

 

back

 

in

 

normal

 

operating

 

mode.

 

 

 

Ready”

 

Place

 

a

 

damp

 

cloth

 

on

 

the

 

plastic

 

bed

 

mat

 

and

 

the

 

light

 

will

 

flash

 

RED

 

on

 

the

 

interface

 

unit.

 

 

Wait

 

for

 

the

 

Enter

 

Location

 

Code

 

prompt

 

then

 

press

 

0

 

(no

 

location)

 

followed

 

by

 

the

 

 

key.

  

 

Wait

 

for

 

the

 

Pendant

 

Enabled

 

 

Enter

 

Flat

 

prompt.

 

 

*Note:

 

if

 

the

 

Enuresis

 

sensor

 

has

 

been

 

activated

 

in

 

the

 

last

 

15

 

minutes

 

you’ll

 

have

 

to

 

reset

 

the

 

MASK

 

TIME

 

 

see

 

page

 

2.

 

 

Summary of Contents for W00369

Page 1: ...de up text on the mat shows THIS SIDE UP 3 If necessary secure the mat with cord through the 4 corner tie down points 4 Ensure the wire exits safely without causing a hazard 5 Place a bath towel over the top of the bed mat for best performance Be aware that nylon or polyester sheets can give false alarms 6 Refit the bottom bed sheet 7 Plug the lead into the interface unit and make sure it is place...

Page 2: ...he bed mat from the interface unit before cleaning The bed mat can be wiped clean with a damp cloth and soapy water or a mild disinfectant Do not fully submerge the bed mat lead or interface unit in water Replacement Bed Mats Due to the nature of the product bed mats are non returnable Replacement mats are available separately order Tynetec Part No W00369 Battery Life The battery is checked once a...

Page 3: ...ght will return to STEADY GREEN The 8 digit ID can be found on a label on the back of the Enuresis interface unit it will always start with 32xxxxxx The instructions given above for the standard Reach product also applies to the Reach Plus Reach Plus GSM and Reach Ultra models Refer to the instruction booklets provided with these products for more information on programming and testing radio devic...

Page 4: ...ion Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for more information on programming and testing radio devices Using the Manager s DECT telephone Press the LINE key and wait for the Ready prompt Enter 5 0 0 0 followed by the key Enter the flat number the Enuresis sensor is being installed in followed by the key You now have 1 minute to activate the Enu...

Page 5: ...and the light will flash RED on the interface unit The display will show Enuresis and the Enuresis sensor 8 digit ID number Check the ID is correct press the key to select Accept then press ENTER Note if another device has been picked up press ENTER to Reject and try again The display will show Flat use the keys to choose the dwelling type Press the key to select No 000000 then press the ENTER key...

Page 6: ...a T32 Details of the Enuresis sensor selected will be displayed in the Room House Code and ID boxes below If the details shown are correct press the Delete button Press the Close button to exit Refer to the Touchsafe Pro Display Panel user guide Doc No FM5505 provided with the Nursecall system for more information Tynetec and Aidcall operate a policy of continuous improvement and reserve the right...

Reviews: