Doc No. FM0804 issue 4 Page 7
240V AC
PIR
DETECTOR
240V AC
240V AC
SMOKE
DETECTOR
CEILING
PULLCORD
DOOR ENTRY
TELEPHONE
MANAGER
CALLPOINT
LIFT CALLPOINT
LIFT MOTOR ROOM
INTERFACE
869MHz
RADIO
DEVICES
DOOR
LOCK
PRESS
TO
EXIT
SYSTEM
NETWORK
MANAGER’S
DISPLAY
PANEL
DIGITAL
DOOR ENTRY
PANEL
DOOR CONTACT
FIRE
ALARM
PANEL
ADVENT XT2
CONTROLLER
ADVENT XT2
PA AMPLIFIER
DECT
CORDLESS
HANDSET
OFFICE DESK
TELEPHONE
MATRIX NE
IP-PBX
XT2
TEL LINE 2
OFFICE
TEL LINE
IP-DECT BASE
STATION
XT2
TEL LINE 1
STANDARD
INTERCOM
DOOR ENTRY
INTERCOM
LOCK
PSU
240V AC
240V AC
ETHERNET
SWITCH
I/O
EXPANDER
DOOR
ENTRY
NETWORK
240V AC
NOTICE BOARD
HDMI
EXTERNAL
BATTERY BOX
6.
SYSTEM OPTIONS
BASIC WIRING REQUIREMENTS
On new installations the System Network should be a 6 pair CW1308 BT spec cable, on sites with existing cabling a
minimum of 5 twisted pairs are required. An additional 10 pair bus is required for the Door Entry Network.
A Cat5e cable (max distance 100 metres) is required between the Ethernet swit
ch and each Manager’s panel, RJ45
wall sockets and patch leads are provided to terminate the Cat5e cable.
See the separate manual (Tynetec Doc No. FM0814) for the DECT telephone system options and wiring requirements.
240V
AC
869MHz
NETWORK
RECEIVER
BROADBAND
ROUTER