5.

 

 RELATED DOCUMENTATION 

 

This guide provides information regarding the installation of the Advent XT2 system. 
You can request copies of the related 

documents listed below from Tynetec’s customer support

 team. 

Tynetec Engineers can download them from the Legrand Dialeg 365 UK AL&H Document Library.  

 

 

Advent XT2 Wiring Diagrams (Drawing No. ZXT900) 

 

Advent XT2 Block Diagram (Drawing No. WD0297) 

 

Advent XT2 IP-DECT System Installation Guide (Doc No. FM0814) 

 

Advent XT2 Programming Guide (Doc No. FM0815) 

 

Advent XT2 Operators Manual (Doc No. FM0816) 

 

Advent XT2 Intercom User Guide (Doc No. FM0818) 

 

Advent XT2 Door Entry Intercom User Guide (Doc No. FM0819) 

 

Advent XT2 Second PA Amplifier Wiring Diagram (Drg No. WD0298) 

 

Advent XT2 Specification (Doc No. FM0788) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Advent XT2

Page 1: ...ght to modify the specification of its products If any variation to the details in this document are suspected please contact Tynetec s Technical Support Tynetec a business unit of Legrand Electric Lt...

Page 2: ...ion 32 22 Network Receiver Installation 38 23 Door Entry Panel Installation 40 24 Door Entry Telephone Installation 43 25 Door Open Alarm Installation 45 26 Line Selector Installation 46 27 Data Repea...

Page 3: ...IP digital protocol for Next Generation Networks NGN s BS8521 and TT92 analogue protocols for traditional PSTN connectivity Simplified future firmware updates via SD card or the Cloud Compatibility m...

Page 4: ...s and cable length restrictions USB Ports are for Engineers use only they are not suitable for charging Smartphones or Tablets This product should be located at least 2 metres away from other electron...

Page 5: ...depot NTENTS 4 MAINTENANCE CARE For peace of mind and to ensure your system is maintained to the highest standard Tynetec recommend an annual maintenance contract This will provide vital assistance in...

Page 6: ...e Legrand Dialeg 365 UK AL H Document Library Advent XT2 Wiring Diagrams Drawing No ZXT900 Advent XT2 Block Diagram Drawing No WD0297 Advent XT2 IP DECT System Installation Guide Doc No FM0814 Advent...

Page 7: ...ERCOM LOCK PSU 240V AC 240V AC ETHERNET SWITCH I O EXPANDER DOOR ENTRY NETWORK 240V AC NOTICE BOARD HDMI EXTERNAL BATTERY BOX 6 SYSTEM OPTIONS BASIC WIRING REQUIREMENTS On new installations the System...

Page 8: ...Button maximum 16 per system W00525 12V 2A Power Supply Unit 1 per door panel for lock supply ZXT955 Door Entry Telephone maximum 2 per intercom master extension REMOTE CONTROL CENTRE PSTN ARC The PS...

Page 9: ...d be wall mounted in a dry secure area which is easily accessible for termination and future service Fix the chassis to the wall using the two keyholes marked A below 20mm Cable Entry Knockouts CPU Bo...

Page 10: ...t with solid state over load over voltage and over temperature protection With the mains connected the green Supply Healthy LED should be illuminated The output voltage is factory set to 27 5V DC with...

Page 11: ...oximity to the Advent XT2 Controller 2 A static IP address and corporate network termination point within close proximity to the ARC and the additional SIP Server Note the static IP addresses at both...

Page 12: ...a bus must not exceed 255 A data repeater P No ZXT340 is available for extreme cases Single auxiliary devices such as external Manager callpoints lift speech units and network receivers can be connect...

Page 13: ...t 102 mA 0 102A on 24V line 400 metres of CW1308 cable 40 10 per 100 metres using V I x R 0 102A x 40 4 08V drop on 24V line leaving approx 20V Devices on the 24V supply will work down to approx 16V t...

Page 14: ...ied to input 4 a 999 fire alarm call will be reported via the current operating mode If a PA Amplifier ZXT901 is fitted then at the same time a fire tone will start to sound through all intercoms The...

Page 15: ...ctions The LED alongside each fuse will extinguish if a fuse is blown Fuse No Rating Function LED F1 1 6A 24V Network 1 LED 3 F2 1 6A 12V Network 1 LED 4 F3 1 6A 24V Network 2 LED 5 F4 1 6A 12V Networ...

Page 16: ...A amplifier input 0V Ground TX RS485 bi directional data bus TX PA AMP 1 INA PA audio 100V line from PA amplifier 1 PA AMP 1 INB PA AMP 2 INA PA audio 100V line from PA amplifier 2 PA AMP 2 INB DOOR E...

Page 17: ...le always ensure none of the original equipment is left connected before terminating the Advent XT2 system Use the following colour code Pair No Diameter Colour Terminal Signal 1 0 8 mm Red 24V Power...

Page 18: ...ould only be removed during installation and service it must be screwed shut at all other times to prevent the risk of electric shock Never leave a live PA amplifier unattended with the lid removed IN...

Page 19: ...second ZXT901 PA Amplifier is required The EN AUD 0V and data RS485 RS485 are simply connected in parallel with the first PA Amplifier however the Transformer output of the second PA Amplifier must b...

Page 20: ...heck the battery leads can be routed through the knockouts and trunking to the XT2 controller before fixing to the wall DO NOT extend the battery leads Fix the chassis to the wall using the 3 holes ma...

Page 21: ...ssage can be played by pressing the MSG button The white SPANNER symbol button is used to enter Test Mode to check the operation of ceiling pullcords personal pendants PIR s etc without activating an...

Page 22: ...r possible avoid cable entry from below as this may interfere with the operation of the emergency pullcord also keep the microphone hole on the lower front face free from obstruction Cable clips are p...

Page 23: ...com Mode Master Extension ON if connected as an Extension Intercom 6 Strobe Disabled Enabled ON if a ZSL060 Strobe is connected 7 Pullcord Type Normally Open Normally Closed ON if normally closed Pull...

Page 24: ...nal inputs and a hard of hearing strobe light within each dwelling CEILING PULLCORDS NORMALLY OPEN CONFIGURATION NORMALLY CLOSED CONFIGURATION Intercom Pullcord 1 24V DC 8 LED 9 N O 0V COM Intercom Pu...

Page 25: ...additional battery backed power supply DO NOT POWER FROM THE ADVENT XT2 SYSTEM Typical PIR detector connections shown Refer to the manufacturer s instructions for the exact PIR model being installed...

Page 26: ...be mains or battery powered or be connected to a separate low voltage supply Additional devices must have a normally open clean contact output which closes on alarm Each input requires a 18K or 47K re...

Page 27: ...h for 20 seconds when the intercom is called in door entry mode DIL switches inside the strobe select if it flashes on a warden call or door entry call and if it is connected as the main primary or ex...

Page 28: ...g downwards and clip together ensuring the pullcord is located in its slots REMOVING THE INTERCOM FRONT Use the pegs on the orange triangle to push the clips one at a time on the lower face whilst pul...

Page 29: ...has received the test alarm Each test alarm is recorded in the Manager s Panel Event Log Once in Test Mode certain conditions have been set to cater for the activation of PIR s and radio devices Thes...

Page 30: ...back of the Manager Callpoint to gain access to the screw terminals Connect to the system network wiring as shown above fit a 4K7 resistor across terminals 2 9 to prevent an open circuit fault being r...

Page 31: ...rface Unit in the motor room Connect the interface unit to the Advent XT2 network wiring as shown above A normally open clean contact momentary action low level Kick Switch supplied by others can be c...

Page 32: ...nd is therefore not operational during a mains failure ETHERNET If there s only one Manager s Display Panel and it s within 3 metres cable run of the Advent XT2 controller then connect the LAN port to...

Page 33: ...M0815 OPTIONAL NOTICE BOARD A large flat screen 1920x1080p HDMI monitor can be connected to the Manager s Panel HDMI port using a standard Male Male HDMI cable max cable length should not exceed 15 me...

Page 34: ...mming allows the site Manager to setup basic system features e g activity monitoring I m OK etc All other system setup must be performed from the XT2 Controller integral display Change Password allows...

Page 35: ...stem the panel should be setup by an Engineer to enable the Windows NTP server allowing all panels to be updated from the Controller This will be documented separately From the System Setup screen pre...

Page 36: ...eeds to know the IP address of the XT2 Controller to pass data between the panel and the controller This IP address can be set in the XT2 IP Address box The Main panel needs to know the number of Sate...

Page 37: ...Select the Password to be changed from the drop down menu Engineer Manager or User Enter a new 4 digit password in the Password box Enter the same new 4 digit password in the Confirm Password box Pre...

Page 38: ...dings differ an RF site survey is recommended for each installation to establish the best locations Construction materials such as foil backed plasterboard reinforced concrete or stone walls will redu...

Page 39: ...Receiver ID ID s are set in Binary they must start at 0 and run sequentially to 31 max do not duplicate ID s DIL switches 6 7 are not used DIL switch 8 must be ON for XT2 DIL Switch No 1 2 3 4 5 6 7 8...

Page 40: ...e top face of the backbox for cable entry this may allow water to enter and damage the electronic components or keypad Cable entry into the backbox should be through any of the 20mm knockouts provided...

Page 41: ...oice messages 6 OFF to disable relay output ON to enable relay output 7 No Function 8 No Function PROGRAMMING The number of door panels must be set in the RS485 Network Setup programming and the lock...

Page 42: ...on should be momentary action with both N O and N C contacts The N O contacts are connected across 0V EXLK in the door panel to provide a timed lock release With fail safe constantly energised locks i...

Page 43: ...rheard by other users from their handsets or visitors at other door panels PUSHBUTTON LED INDICATOR INSTALLATION The door entry telephone should be wall mounted alongside or close to the intercom unit...

Page 44: ...t is not possible to have more than 2 telephones per flat Note the Advent XT2 controller must be reset for it to detect a second telephone handset has been connected OPTIONAL HARD OF HEARING STROBE Ha...

Page 45: ...Open Alarm alongside the monitored door at a height where the isolation key switch can easily be reached TERMINATION Connect 1 pair of wires to a standard N C door contact available separately Tynetec...

Page 46: ...ocket to the Line Selector PRIMARY socket Use a Telecom Lead to connect the GSM Cellular Terminal to the Line Selector SECONDARY socket PROGRAMMING DTMF Relay 3 must be disabled FF in the Inputs Outpu...

Page 47: ...FF DIL Switch ON 1 RS485 IN EOL 1 Leg open circuit 120 ohms 2 RS485 IN EOL 2 Legs open circuit 270 ohms 3 RS485 IN EOL 3 Legs open circuit 390 ohms 4 RS485 IN EOL 4 Legs open circuit 680 ohms SW2 allo...

Page 48: ...6 No of Network Receivers 32 No of Speech Channels 2 Audio Control HVS Hands Free Voice switching warden call and door entry mode No of ARC Tel Numbers 20 No of PR Tel Numbers 3 per intercom Power Sup...

Page 49: ...very Mains Input IEC 90o Free Socket Rechargeable Battery Type 1 x 12V 5Ah Sealed Lead Acid Tynetec P No F00050 Battery Standby Time 8 Hours Typical DC DC Converter Manufacturer Model No Ecopac SD 50A...

Page 50: ...typical 40 way system Battery Leads 1 3m x 24 0 2 PVC insulated wire BS 4808 Part 2 Crimp Adapter Type 2 Way Tab to Receptacle 4 8mm x 0 8mm TE Connectivity 63699 1 Fuse Type 20mm 3 15A S B Mechanica...

Page 51: ...er Halo with symbol text amber LED indicator Door Open Button ZFT930 31 only Green Halo with symbol text green LED indicator All Call Speech Yes optional ZXT901 PA Amplifier required All Call Fire Ton...

Page 52: ...itch No Function Features Inputs 6 x Programmable N O Inputs switched 0V Outputs 6 x Programmable C O Relay Outputs contacts rated 30V DC 1A Mechanical Enclosure Material Light Grey ABS RAL 7035 Flamm...

Page 53: ...Loudspeaker Protected by Fine Mesh Stainless Steel Grill Microphone Protected by Fine Mesh Stainless Steel Grill DDA Compliance High Visibility Yellow Halo around Pushbutton Engraving ZXT940 MANAGER B...

Page 54: ...ne Protected by Fine Mesh Stainless Steel Grill DDA Compliance High Visibility Yellow Halo around Pushbutton Engraving ZXT942 CALL Black infill 5mm high ZXT943 Custom Engraved Audible Reassurance No V...

Page 55: ...ED illuminated symbol I m OK Button No Function Privacy Button No Function Message Waiting Button No Function Test Mode Button No Function Audible Reassurance No Visual Indication Red Call LED Kick Sw...

Page 56: ...SMA Dipole Antenna 195mm long Antenna Connection SMA RP Gold Female Bulk Head with 5cm 1 13mm diameter U FL 8 Way DIL Switch 1 to 5 Binary ID 6 7 Not Used 8 Protocol OFF TSP ON XT2 LED Indicators LED1...

Page 57: ...dio Video Speaker Output 2 x 2 Watt Stereo Audio Interface Line Out Camera 2 MP Power Supply Manufacturer Model No Delta Electronics Inc ADP 40KD BB Input 100 240V AC 1 2A 50 60Hz Output 19VDC 2 1A 40...

Page 58: ...klit LCD 8mm High Characters Display Contrast Adjustable Display Window 5mm Clear Makralon Polycarbonate Panel Mount Reader Option Yes standard 40mm square cut out with 4 studs on 48 5mm centres Lock...

Page 59: ...Lock Release Functions LED Indicator 1 Tricolour LED Red Privacy Green Door Open Audio Handsfree Voice Switched Digital Volume Control Call Visual Indication Yes optional ZSL041 Amber Strobe required...

Page 60: ...ting Humidity 10 to 90 RH Relative Humidity Non condensing 41 SPECIFICATION DATA REPEATER Tynetec Part No ZXT340 EMC Approval N A Safety Approval N A Features Power Requirement 24V DC 10mA standby Lin...

Page 61: ...to 5 minutes Piezo Sounder 4kHz 80dB 10cm Relay Output Changeover contacts rated 30V DC 1A Door Contact Normally Closed Type not supplied Keyswitch 2 position key removeable in both positions Key No...

Page 62: ...2 Flammability Rating UL 94 HB Ingress Protection Rating IP40 Dimensions 110mm diameter x 57mm deep Weight 135 grams Environmental Operating Temperature 0o C to 40o C Operating Humidity 10 to 90 RH Re...

Page 63: ...le below lists significant changes to this manual Issue Amendments Date 1 Preliminary issue 16 08 18 2 Manager s Panel setup details added 27 09 18 3 NTR Antenna changed Currents added Ext Battery Box...