10
Positioning the heater - recess installation
To position the sauna heater in a recess:
1. Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 5).
2. Position the sensor according the picture (see Figure 5).
1
2
3
4
5
Figure 2: Schematic diagram of installation
1. Sauna heater
2. Control panel
3. Sensor
4. External on/off switch (option, door contact needed for func-
tion)
5. Door contact (option)
Positioning the heater - normal installation
DANGER! No more than one heater may be instal-
led in the same sauna cabin.
Position the sauna heater:
•
on the same wall as the door (or the side wall if very close
to the door wall). The heater may also be placed in a recess
(see Figure 5).
•
Position the heater at a safe distance from the fl oor, side
walls and interior fi ttings (see Figure 3).
Position the sensor according the picture (see Figure 3).
If the wall on which the sensor is to be installed is made of highly
heat-absorbing material (e.g. concrete, brick, etc.), or of hardened
glass, the sensor may be installed in the ceiling at a distance from
the heater, according to Figure 4.
1
4
8
11
10
12
2
6
5
9
7
3
3
Figure 3: Positioning the heater - normal installation
1. Minimum distance from side wall: 110 mm
2. Sensor position alt 1: 300 mm from heater
3. Sensor
4. Minimum distance from back wall (with legs): 95 mm
5. Sensor position alt 2: 300 mm from heater front
6. Sensor position: 150 mm from ceiling
7. Minimum distance from ceiling: 1030 mm
8. Minimum distance from interior fi ttings: 100 mm
9. Minimum ceiling height: 1900 mm
10. Minimum distance: 20 mm
11. Minimum distance from interior fi ttings: 30 mm
12. Distance from fl oor: 100-270 mm (with legs: 100 mm)
Figure 5: Positioning the heater - recess installation
1. Minimum distance from side wall: 110 mm
2. Sensor position alt 1: 300 mm from heater
3. Sensor
4. Max. 1000 mm
5. Sensor position alt 2: 300 mm from heater front
6. Sensor position: 150 mm from ceiling
7. Minimum distance from ceiling: 1030 mm
8. Minimum distance from interior fi ttings: 100 mm
9. Minimum ceiling height: 1900 mm
10. Minimum distance: 20 mm
11. Minimum distance from interior fi ttings: 30 mm
12. Distance from fl oor: 100-270 mm (with legs: 100 mm)
Figure 4: Ceiling installation of the sensor
1. 300 mm
1
1
8
11
10
12
4
1
1
9
7
2
6
3
5