13
Figure 17: Wiring diagram
1. NTC Sensor
2. Ext switch (External switch)
3. Door switch (Door contact)
4. SEC/NTC Sensor (option)
5. RS485 control panels
6. RS485 control panels
7. RS485 control panels
8. RS485 control panels
9. Heater
10. Terminal for connection of electrical cable
11. Control panel (connect to positions 5-8)
12. Sensor (connect to NTC position 1)
13. Light/terminal for connection of light
14. Door contact (option)
15. External switch (option)
9
13
14
15
11
12
1
2
3
4
5
6
7
8
11
10
13
RJ10 4P4C
2 x 0.75 mm
2
RJ10 4P4C
RJ10 4P4C
RJ10 4P4C*
* Control panel Pure - max 100m
B
B
6,6-8,0 kW
200-240 V 1N~/2~
6,6-8,0-10,5 kW
200-230 V 3~
6,6-8,0-10,5 kW
400-415 V 3N~
Max 100W/0,5A
Unusual voltages/numbers of phases
Contact Tylö Customer Service before connecting to voltages or num-
bers of phases that are not listed in the wiring diagram Figure 17.
Figure 15: Installing the sensor
Figure 16: Seal any holes
CONNECTION/WIRING DIAGRAM
TAB
400-415 V 3N~/3~ (C) 200-208 V 3~ (B)
230-240 V 3~ (B)
200-208 V~ (A)
230-240 V~ (A)
Output
kW
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
6,6
10
1,5
19
4
17
4
33
10
29
10
8
12
2,5
23
4
20
4
40
16
35
10
10,5
16
2,5
32
10
28
10
-
-
-
-