12
Figure 12: Fitting the fragrance holder/air humidi
fi
er
11.
Hang the heater on the screws see Fig. 13.
8.
Unscrew the fi rst two screws on the back of the heater and
screw one of the four brackets into place. Repeat the proce-
dure until all of the brackets are fi tted see Fig. 10.
Figure 13: Hang the heater up.
12.
Lock the heater into place with the lock screw see Fig. 14.
Figure 14: Lock screw for bracket
13.
Install the sensor on the wall see Fig 15. The thermistor wire
may also be passed through the wall. Seal any holes in the
wall behind the sensor, see Figure 16, page 11. The ther-
mistor wire may be extended outside the sauna using low
voltage wire (2-lead).
Figure 11: Dimensioning
1. 262 mm
2. 270 mm
3. 532 mm
4. 206 mm
10.
Fit herb bowl/air humidifi er (see Fig. 12).
NB: If all the screws on the back are unscrewed
simultaneously, the back plate may come loose.
For this reason, attach the four brackets to the
heater one at a time.
Figure 10: Attaching the brackets to the heater
9.
Position the bracket screws according to the specifi ed dimen-
sioning see Fig. 11.
2
4
3
1
4.
Run the cables for the control panel and the temperature
sensor through the cable grommets (3). Connect the control
panel cable (4) to one of the four RS485 contacts (positions
5-8) (see Figure 9) according to the wiring diagram (see the
Connection/wiring diagram section).
5.
Connect the sensor cable (6) to the NTC contact on the circu-
it board (position 1) (5) (see the Connection/wiring diagram
section) according to the wiring diagram (see the Connection/
wiring diagram section, page 11).
6.
Connect the light cable (if relevant) (7), see Figure 9, to the
terminal (8) according to the wiring diagram Figure 17.
7.
Close the cover and tighten the screws (see Figure 8).
2
8
4
5
7
6
9
1
10
3
Figure 9: Circuit board
1.
Electrical cable
2.
Terminal for connection of electri-
cal cable
3.
Cable grommet (x6)
4.
Control panel cable
5.
Modular contacts for connection
of control panel, sensor etc.
6.
Sensor cable
7.
Light cable (if relevant)
8.
Terminal for connection of
light (if relevant)
9.
Strain relief connector for
cables to modular contacts
(x2)
10. Strain relief connector for
electrical cable