background image

9

 

 

SPECIFICATIONS 

            

Subject to change without notice

 

 

 

RPST12M

 

RPST24M

 

Battery Capacity (12V)

 

100Ah or 200Ah  

 

Reserve Power @  Rated Load

 

>24 hours  

 

Load Output  

 

12V 20A —

Unregulated

 

24V 20A —

Unregulated

 

Battery Voltage (DC)

 

12V 

 

24V

 

Battery Type

 

Valve Regulated Sealed Lead Acid 

AGM

 

Battery Life

 

5 Years  

 

Controller Type

 

MPPT—Temperature Compensated

 

Over

-

Voltage Protection

 

16V

 

32V

 

Bulk Charge

 

14.4V   

 

28.8V   

 

Float Charge

 

13.8V   

 

27.6V   

 

Over

-

discharge protection

 

11.1V   

 

22.2V   

 

Over

-

discharge recovery voltage

 

12.6V   

 

25.2V   

 

Controller Self Consumption

 

<1W  

 

Enclosure Type

 

Powder Coat Steel  

 

Wind Survivability

 

90MPH

 

Operating Temperature

 

-

30°C to +60°C  

 

battery chargers that can be used in parallel with the solar con-

troller to charge batteries from AC.

 

 

Replacement Parts

 

Solar Controller:  

TP

-

SC24

-

20

-

MPPT, TP

-

SC24

-

40

-

MPPT

 

Batteries: 

TPBAT12

-

52

 

Solar Mount: 

TPSM

-

80X4

-

UNI (2

-

4panels) 

 

Solar Panel: 

TPS

-

12

-

80W

 

 

Note

: Maximum solar panel size for the TP

-

SC24

-

20

-

MPPT and TP

-

SC24

-

40

-

MPPT controllers.

 

20A MPPT

 

40A MPPT

 

 

260W

 

520W

 

12V Battery

 

24V Battery

 

520W

 

1040W

 

Summary of Contents for RemotePro RPST12M

Page 1: ...ith overhead power lines lights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install...

Page 2: ...erVent plate STEP 3 Install hole plug in drain hole in bottom right corner of the en closure STEP 4 Mount the DIN rail to the door using screws provided Mount any extra equipment to the orange backplate and secure the backplate in the enclosure Note The DIN rail can also be mounted to the orange back plate or sides of enclosure if desired STEP 5 If pole mounting the enclo sure assemble the pole mo...

Page 3: ...e recommend using the optimum angle for winter sun You can also calculate winter tilt us ing Your_Latitude 0 9 30 Mount the solar panel mount to the pole using hose clamps provided Be sure to mount high enough so the door of the enclosure clears the solar panel mount when opened You can also mount the panel to a wall using lag bolts STEP 9 Attach the solar panel to the solar panel mount so that th...

Page 4: ...4 Panels without pre installed MC 4 Connectors Configurations MC 4 Connectorized Panels Wiring Configurations 24V Two Panel Configuration 24V Four Panel Config ...

Page 5: ...5 CAUTION Be sure to connect the bat tery to the controller first and disconnect it last Connecting so lar panels to the con troller without the battery connected could damage the controller ...

Page 6: ...ith electrical tape to avoid any shorting of the panels STEP 10 Install the batteries in the enclosure If using multiple batter ies connect in parallel for 12V output or connect in series for 24V output The solar controller will automatically de tect the battery voltage If batteries are installed on their side make sure to apply an insulator included to the top of the battery terminal to prevent t...

Page 7: ... and hinge area Use the special key to close the two cover locks TECH CORNER Additional Information you may find useful 1 CONTROLLER The 12V controller turns off power to the load at 11V and reconnects when the battery reaches 12 5V The 24V control ler turns off power at 22V and reconnects at 24 5V This protects bat tery from overdischarge and increases battery life and performance 2 Controller LE...

Page 8: ...ou will most likely need to recondition them with a good quality 10A automotive battery charger Avoid charging for longer than 24hrs to avoid battery damage Once they are back to a normal operating range the integrated charge controller will maintain the charge 10 TROUBLESHOOTING A There is no load output from the controller If battery voltage is too low the charge controller will turn off the loa...

Page 9: ...27 6V Over discharge protection 11 1V 22 2V Over discharge recovery voltage 12 6V 25 2V Controller Self Consumption 1W Enclosure Type Powder Coat Steel Wind Survivability 90MPH Operating Temperature 30 C to 60 C battery chargers that can be used in parallel with the solar con troller to charge batteries from AC Replacement Parts Solar Controller TP SC24 20 MPPT TP SC24 40 MPPT Batteries TPBAT12 52...

Page 10: ... to 15m Uses a smartphone app available for Android and IOS devices Completely weatherproof for outdoor mounting Low Cost TPW 400DT 12 24 400W 12V 24V Wind Turbine Includes Integrated Controller with Dump Load Good low wind performance Self braking in high wind 110MPH survivability Sealed and maintenance free Very Quiet Low vibration ...

Page 11: ...monitoring over the internet Qty 4 10A relays for controlling power to devices starting a generator etc Measures internal and external tem peratures Intuitive user interface and graphical setup SNMP compatability Shunt compatible for measuring very high currents Email Alerts Programmable functionality Notes ...

Page 12: ...per installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage for units that were not mounted according to user manual Usage other than in accordance with instructions and the normal intended use Tycon Systems 14641 S 800 W Bluffdale UT 84065 support tyconsystem...