background image

PowerSeries Pro Installation Guide

Limited Warranty

Digital Security Controls warrants the original purchaser that for a period
of twelve months from the date of purchase, the product shall be free of
defects in materials and workmanship under normal use. During the
warranty period, Digital Security Controls shall, at its option, repair or
replace any defective product upon return of the product to its factory, at
no charge for labour and materials. Any replacement and/or repaired parts
are warranted for the remainder of the original warranty or ninety (90)
days, whichever is longer. The original purchaser must promptly notify
Digital Security Controls in writing that there is defect in material or
workmanship, such written notice to be received in all events prior to
expiration of the warranty period. There is absolutely no warranty on
software and all software products are sold as a user license under the
terms of the software license agreement included with the product. The
Customer assumes all responsibility for the proper selection, installation,
operation and maintenance of any products purchased from DSC. Custom
products are only warranted to the extent that they do not function upon
delivery. In such cases, DSC can replace or credit at its option.

International Warranty

The warranty for international customers is the same as for any customer
within Canada and the United States, with the exception that Digital
Security Controls shall not be responsible for any customs fees, taxes, or
VAT that may be due.

Warranty Procedure

To obtain service under this warranty, please return the item(s) in question
to the point of purchase. All authorized distributors and dealers have a
warranty program. Anyone returning goods to Digital Security Controls
must first obtain an authorization number. Digital Security Controls will
not accept any shipment whatsoever for which prior authorization has not
been obtained.

Conditions to Void Warranty

This warranty applies only to defects in parts and workmanship relating to
normal use. It does not cover:

l

l

damage incurred in shipping or handling;

l

damage caused by disaster such as fire, flood, wind, earthquake or
lightning;

l

damage due to causes beyond the control of Digital Security
Controls such as excessive voltage, mechanical shock or water
damage;

l

damage caused by unauthorized attachment, alterations,
modifications or foreign objects;

l

damage caused by peripherals (unless such peripherals were
supplied by Digital Security Controls Ltd.);

l

defects caused by failure to provide a suitable installation
environment for the products;

l

damage caused by use of the products for purposes other than
those for which it was designed;

l

damage from improper maintenance;

l

damage arising out of any other abuse, mishandling or improper
application of the products.

Items Not Covered by Warranty

In addition to the items which void the Warranty, the following items shall
not be covered by Warranty: (i) freight cost to the repair centre; (ii)
products which are not identified with DSC's product label and lot number
or serial number; (iii) products disassembled or repaired in such a manner
as to adversely affect performance or prevent adequate inspection or
testing to verify any warranty claim. Access cards or tags returned for

replacement under warranty will be credited or replaced at DSC's option.
Products not covered by this warranty, or otherwise out of warranty due to
age, misuse, or damage shall be evaluated, and a repair estimate shall be
provided. No repair work will be performed until a valid purchase order is
received from the Customer and a Return Merchandise Authorization
number (RMA) is issued by DSC's Customer Service.

Digital Security Controls Ltd.’s liability for failure to repair the product
under this warranty after a reasonable number of attempts will be limited to
a replacement of the product, as the exclusive remedy for breach of
warranty. Under no circumstances shall Digital Security Controls be liable
for any special, incidental, or consequential damages based upon breach of
warranty, breach of contract, negligence, strict liability, or any other legal
theory. Such damages include, but are not limited to, loss of profits, loss
of the product or any associated equipment, cost of capital, cost of
substitute or replacement equipment, facilities or services, down time,
purchaser’s time, the claims of third parties, including customers, and
injury to property. The laws of some jurisdictions limit or do not allow the
disclaimer of consequential damages. If the laws of such a jurisdiction
apply to any claim by or against DSC, the limitations and disclaimers
contained here shall be to the greatest extent permitted by law. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so that the above may not apply to you.

Disclaimer of Warranties

This warranty contains the entire warranty and shall be in lieu of any and
all other warranties, whether expressed or implied (including all implied
warranties of merchantability or fitness for a particular purpose) and of all
other obligations or liabilities on the part of Digital Security Controls.
Digital Security Controls neither assumes responsibility for, nor authorizes
any other person purporting to act on its behalf to modify or to change this
warranty, nor to assume for it any other warranty or liability concerning
this product. This disclaimer of warranties and limited warranty are
governed by the laws of the province of Ontario, Canada.

WARNING: Digital Security Controls recommends that the entire system
be completely tested on a regular basis. However, despite frequent testing,
and due to, but not limited to, criminal tampering or electrical disruption, it
is possible for this product to fail to perform as expected.

Out of Warranty Repairs

Digital Security Controls will at its option repair or replace out-of-
warranty products which are returned to its factory according to the
following conditions. Anyone returning goods to Digital Security Controls
must first obtain an authorization number. Digital Security Controls will
not accept any shipment whatsoever for which prior authorization has not
been obtained.

Products which Digital Security Controls determines to be repairable will
be repaired and returned. A set fee which Digital Security Controls has
predetermined and which may be revised from time to time, will be
charged for each unit repaired.

Products which Digital Security Controls determines not to be repairable
will be replaced by the nearest equivalent product available at that time.
The current market price of the replacement product will be charged for
each replacement unit.

WARNING - READ CAREFULLY

Note to Installers

This warning contains vital information. As the only individual in contact
with system users, it is your responsibility to bring each item in this
warning to the attention of the users of this system.

System Failures

This system has been carefully designed to be as effective as possible.
There are circumstances, however, involving fire, burglary, or other types

- 33 -

Summary of Contents for PowerSeries Pro HS3032

Page 1: ...10xLRSTUL y A B or C A ULC listed models B UL listed models C European and Australian models 4 wire smoke detectors FSA 410xUL FSA 410xTUL FSA 410xSUL FSA 410xSTUL FSA 410xLSTUL FSA 410xRUL FSA 410xRT...

Page 2: ...nnect device If the neutral wire cannot be identified then this equipment must be connected to a mains source that comes from a disconnect device that simultaneously disconnects both poles Line and Ne...

Page 3: ...instructions provided with the module 9 Wire the tamper switch into any available zone Configure the tamper for normally closed NC supervision Zone must be programmed for 24 hour latching or non latch...

Page 4: ...owing terminals are available on the PowerSeries Pro alarm controller Table 1 2 Terminal descriptions Terminal Description BAT BAT Battery terminals Use to provide backup power during a power outage a...

Page 5: ...A continuous rating 2 A short term Available only with standby battery connected DO NOT exceed the 700 mA load for UL ULC or EN certified applications HSM3350 AUX1 AUX2 3 A Subtract the listed rating...

Page 6: ...erride the option in 013 Observe the following guidelines when wiring zones l For UL listed installations use SEOL or DEOL only l Minimum 22 AWG wire maximum 18 AWG l Do not use shielded wire l Do not...

Page 7: ...otion detectors To configure TEOL supervision per zone use programming section 002 bit 15 Figure 1 10 TEOL wiring Note Resistor values are configurable in section 004 Bell wiring These terminals suppl...

Page 8: ...ted on the sticker attached to the device The format is XXX YYYY where l XXX identifies the type or model of the device l YYYY is a short encrypted ID used by the system to identify the specific devic...

Page 9: ...l To assign a keypad to a partition key in 01 08 for partition 1 8 3 Press the key and repeat step 2 for next keypad When finished programming all keypads press the key twice to exit programming Users...

Page 10: ...resent on the system Note When additional information is available for a specific trouble condition a is displayed Press the key to view the additional information 2 Trouble Display This feature is us...

Page 11: ...A temperature sensor falls below the low temperature warning threshold 11 Probe Disconn The probe on the flood detector or the temperature detector is disconnected 12 Fire Trouble A smoke sensor is i...

Page 12: ...915 MHz North America 433 MHz Europe and 912 919 MHz international Access Codes l Up to 1003 access codes 1000 level 2 EN one installer code level 3 EN one maintenance code and one guard code l Progr...

Page 13: ...ies with TS203 021 1 2 3 Telecom equipment require ments and EN50136 1 EN50136 2 ATS SP3 DP2 when used in conjunction with Ethernet and or Cellular paths l The integral Ethernet communication port and...

Page 14: ...0 24 Hour Non Latching Tamper 061 24 Hour Masking 066 Momentary Keyswitch Arm 067 Maintained Keyswitch Arm 068 Momentary Keyswitch Disarm 069 Maintained Keywsitch Disarm 071 Doorbell Zone 072 Push to...

Page 15: ...larm 05 Panic Alarm 06 Burglary Alarm 07 Medical Alarm 08 Supervisory 09 Priority Event 10 Holdup 11 Duress 12 Emergency 13 Fire Supervisory 14 Fire Trouble 15 CO Alarm 157 System Tamper 01 True Outpu...

Page 16: ...tition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Partition 8 201 208 Partition 1 8 Zone Assignment 001 Zone 1 8 002 Zn 9 16 003 Zn 17 24 004 Zn 25 32 005...

Page 17: ...eiver 3 06 Alt Comm Receiver 3 Restore 07 Alt Comm Receiver 4 08 Alt Comm Receiver 4 Restore 355 Alternate Communicator 5 01 Alt Comm Receiver 1 Supervision Failure 02 Alt Comm Receiver 1 Supervision...

Page 18: ...iday 07 Saturday 404 Interval 4 Holiday Assignment 09 Holiday 1 10 Holiday 2 11 Holiday 3 12 Holiday 4 711 714 Holiday Group 1 4 001 099 Holiday Group 1 4 Date 1 99 000000 MMDDYY Audio Station Program...

Page 19: ...Arming and Disarming Notifications 04 Trouble and Trouble Restore Notifications 05 Test Transmission Notifications 06 Reserved 07 Reserved 08 Reserved 693 Session 3 Notification Control 01 Alarm and A...

Page 20: ...ODUCT installed b Storage Network Use The SOFTWARE PRODUCT may not be installed accessed displayed run shared or used concurrently on or from different computers including a workstation terminal or ot...

Page 21: ...MSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT LIABILITY OR ANY OTHER LEGAL THEORY SUCH DA...

Page 22: ...011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060...

Page 23: ...11 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 1...

Page 24: ...06 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 Module Record Module Type Slo...

Page 25: ...PowerSeries Pro Installation Guide Installer Defined Access Codes 001 Installer Code 002 Master Code 003 Maintenance Code System Account Code 25...

Page 26: ...in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleepin...

Page 27: ...rrupted service Equipment Maintenance Facility If trouble is experienced with this equipment HS3032 HS3128 HS3248 for repair or warranty information please contact the facility indicated below If the...

Page 28: ...ty applications the integral Ethernet communicator or the plug in cellular modules Models LE9080 3G9080 or 3H9080 shall have the Encryption Key enabled AES128 bit encryption algorithm is validated und...

Page 29: ...by the person operating the security system during the daily arming and disarming cycle Protection of the Control Unit The local control unit and the local power supply must be protected in one of the...

Page 30: ...with HSM2HOST8 Wireless Transceiver mounted in the HSC3020CP plastic enclosure meets the requirements of Grade 2 Class II equipment as per EN50131 1 2006 A1 2009 A2 2017 Standards The model HS3032P H...

Page 31: ...laration of conformity DoC for this product can be found at www dsc com under the Agency Listings section SIA False Alarm Reduction Installations Quick Reference Minimum required system consists of on...

Page 32: ...elected user codes send a duress reporting code to the central station when used to perform any function on the system Section 019 option 6 must be enabled Default N Required Cancel Window 377 002 opt...

Page 33: ...or damage shall be evaluated and a repair estimate shall be provided No repair work will be performed until a valid purchase order is received from the Customer and a Return Merchandise Authorization...

Page 34: ...nt that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm Smoke Detectors Smoke detectors that are a part of...

Page 35: ...or any kind of construction activity inside or outside the premises The testing should include all sensing devices keypads consoles alarm indicating devices and any other operational devices that are...

Page 36: ...secution wherever necessary All trademarks not owned by Tyco are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specificati...

Reviews: