Section 5 Programming Descriptions
27
6SHFLDO,QVWDOOHU)XQFWLRQV
6HFWLRQ>@7HPSODWH3URJUDPPLQJ
Selecting
[
][8] [Installer Code] [899]
displays the current 5 digit template programming code. Refer to Appendix C - Template Program-
ming for a detailed description of available templates and corresponding 5 digit codes. After entering a valid 5 digit template programming
code, you will be prompted to enter the following in the sequence below:
1. Central Station Telephone Number, enter 32 Character Telephone number
Program the required Central Station phone number. Press
[#]
to complete your entry. This phone number will be entered into programming
section [301].
2. Central Station Account Code, enter 6-digit code
Program the required Central Station Account Code. Press
[#]
to complete your entry. This account code will be entered into programming
section [310].
3. Partition Account Code, enter 4-digit code
This programming section will only be prompted if Contact ID has been selected as a communications format. Program the required Parti-
tion Account Code. Press
[#]
to complete your entry. This Partition account code will be entered into programming section [311].
4. DLS Access Code, enter 6-digit code
Program the required DLS Access Code. This Access Code will be entered into programming section [403].
5. Partition 1 Entry Delay 1, Partition 1 Exit Delay, enter each 3-digit delay time
Program the desired 3 digit Partition 1 Entry Delay (in seconds) followed by the desired 3 digit Partition 1 Exit Delay (in seconds). Press
[#]
to complete your entry. These values will be entered in programming section [005] sub-section [01] entry 1 and 3 respectively.
6. Installers Code
Enter the required 4 or 6 digit access code installers access code (dependent on Section [701] option 5). Press
[#]
to complete your
entry. This Installer Access Code will be entered into programming section [006].
After the Installers Code has been programmed the keypad will return to base installers programming menu.
All template programming information must be re-entered after performing a hardware or software panel default.
6HFWLRQ>@3DQHO9HUVLRQ'LVSOD\HG
Only available with LCD5500 or PK5500 keypads. The system will display the version of the control panel (for example, [0410] indicates
panel version 4.10).
6HFWLRQ>@,QVWDOOHU:DON7HVW
The system will turn Installer Walk Test
ON
. The Ready, Armed and Trouble LED’s will flash rapidly while the test is active. Every time a
zone is violated the system will activate the bell output for two seconds and log the event to the event buffer. To turn Installer Walk Test
OFF
enter Section
[901]
again. The system automatically terminates the test of there is no zone activity for 15 minutes.
6HFWLRQ>@0RGXOH6XSHUYLVLRQ5HVHW
All modules are automatically detected within one minute after being connected to the Keybus. Enter Section [902] to clear detected mod-
ules if a module is removed, if PC5108 jumpers are changed, or if a keypads slot assignments are programmed. The system will rescan the
Keybus to determine which modules are connected.
6HFWLRQ>@9LHZ0RGXOH6XSHUYLVLRQ
The keypad will display the modules detected by the system by turning on the associated zone light (LED keypads), flashing the numbers
(fixed-message LCD keypads) or displaying the modules detected in plain language (programmable LCD keypads). Refer to the chart:
6HFWLRQ>@:LUHOHVV3ODFHPHQW7HVW
Enter Section
[904]
followed by the 2-digit number of the wireless zone to test. When a wireless signal is received from the selected trans-
mitter, the system will indicate the location as
Good
or
Bad
as follows:
Good:
One bell squawk, 1 keypad beep, keypad zone light
[1]
ON
Bad:
Three bell squawks, 3 keypad beeps, keypad zone light
[3]
ON
Press
[#]
to exit when testing is complete. Enter the 2-digit zone number for the next wireless device to test or press
[#]
to return to standard
programming.
6HFWLRQ>@'HIDXOW0DVWHU&RGH
Enter Section
[989][Installer Code][989]
to reset the master code to the factory default.
Indicator Light
(Zone)
Module
Indicator Light
(Zone)
Module
[01] to [08]
[09] to [14]
[15]
[16]
[17]
[18]
Keypad in Slot #1 to #8
PC5108 Zone Expander #1 to #6
PC5100 Module
PC5108 Zone Expander #7
RF5132 Module or RFK keypad with wireless receiver
PC5208
[19]
[20]
[21]
[22]
[24]
[26] to [29]
PC5204 Module
PC5400 Module
PC59xx Module
Alternate Communicator
Escort5580 or Escort5580TC
PC5200 #1 to #4