Section 5 Programming Descriptions
15
>@6HFRQG6\VWHP2SWLRQ&RGH
6HFWLRQ>@7KLUG6\VWHP2SWLRQ&RGH6HFWLRQ
>@)RXUWK6\VWHP2SWLRQ&RGH
[7]
ON:
the system will
NOT
log additional alarms for a zone that has reached the swinger shutdown threshold.
OFF:
all zone alarms will be logged.
[8]
ON:
Temporal Three Fire Signal is used to annunciate fire alarms (½ second ON, ½ second OFF, ½ second ON, ½ second OFF ½
second ON, 1 ½ seconds OFF).
OFF:
the system will pulse the bell output (½ second ON, ½ second OFF).
Option
Description
[1]
ON:
the system squawks the bell output once when a partition is armed, twice when disarmed.
OFF:
the bell output does not activate.
[2]
ON:
the system squawks the bell output every 10 seconds during the auto-arm pre-alert.
OFF:
the bell output does not activate.
[3]
ON:
the system will squawk the bell output once every second during
Exit Delay
, 3 squawks per second for the last 10 seconds.
OFF:
the bell output will not activate.
[4]
ON:
the system will squawk the bell output once every second during
Entry Delay
, 3 squawks per second for the last 10 seconds.
OFF:
the bell output will not activate.
[5]
ON:
the system squawks the bell output once every 10 seconds when a trouble condition is present.
OFF:
the bell output does not activate.
[6]
ON:
the system will beep the keypads once every second, and 3 times a second during the last 10 seconds, during exit delay when
the system is armed with a user code or armed in the Away mode.
OFF:
the keypads will not beep.
[7]
ON:
the exit delay will be terminated (reduced to 5 seconds) when a Delay 1 zone is violated and restored after the system is armed.
OFF:
the exit delay will count down as normal.
[8]
ON:
the bell output will not timeout if a fire alarm occurs. The user must turn off the bell by entering a valid user code.
OFF:
the bell output will timeout normally.
Option
Description
[1]
ON:
The keypad
[F]
fire emergency key will be enabled.
OFF:
The keypad
[F]
fire emergency key will be disabled.
[2]
ON:
The keypad
[P]
panic emergency will be audible (bell output).
OFF:
The keypad
[P]
emergency key will be silent.
[3]
ON:
The
Quick Exit
feature will be enabled.
OFF:
The
Quick Exit
feature will be disabled.
[4]
ON:
The Quick Arming
[
][0]
feature will be enabled.
OFF:
Quick Arming
[
][0]
feature will be disabled.
If this feature is disabled, a valid user code must be entered after the
Stay
or
Away
function buttons are pressed.
[5]
ON:
A valid user code must be entered after pressing
[
][1]
to access the Bypass feature.
OFF:
A user code is not required.
[6]
ON:
The Master Code (user code 40) can only be changed in Installer Programming.
OFF:
The Master Code can be changed using the User Programming
[
][5]
command.
[7]
ON:
The system supervises the telephone line and displays a trouble if disconnected.
OFF:
the telephone line is not supervised.
[8]
ON:
The system activates the bell output if a telephone line trouble is detected while the system is armed.
OFF:
The system activates the keypad buzzer trouble tone.
Option
Description
[1]
ON:
The system supervises the AC input and displays a trouble if a failure is detected.
OFF:
AC Input is not supervised.
[2]
ON:
The trouble light will flash when an AC trouble is detected.
OFF:
The trouble light turns on, does not flash.
[3]
ON:
The keypad blanks (no indicator lights) if a key is not pressed for 30 seconds.
OFF:
The keypad does not blank.