![Tyco DSC PowerSeries PC1616 Instruction Manual Download Page 12](http://html1.mh-extra.com/html/tyco/dsc-powerseries-pc1616/dsc-powerseries-pc1616_instruction-manual_1185941012.webp)
PowerSeries - PC1616/PC1832/PC1864
8
>
@>@7URXEOH'LVSOD\
Refer to Appendix B – Troubleshooting Guide, for troubleshooting assistance and a detailed description of all trouble conditions.
Press
[9]
to acknowledge and override all existing troubles. Pressing
[9]
allows the panel to be armed, and will generate and log an
override event. A General System Supervisory caused by a hardwired or wireless zone expander cannot be overridden by this method.
If Section
[701]
option
3
is
ON
arming will be inhibited if a system low battery or AC trouble is detected and cannot be overridden by
this method.
Press
[8]
in the trouble menu on any new PowerSeries keypad to enter the time and date programming menu. This option will be
available if a Loss of Clock trouble is present on the system.
>
@>@$ODUP0HPRU\'LVSOD\
The Memory light will be ON if an alarm occurred during the last armed period. Press
[
][3]
. The Memory light will flash and the keypad
will display the zones that went into alarm.
To clear the Memory light, arm then disarm the system.
>
@>@'RRU&KLPH(QDEOH'LVDEOH
Press
[
][4]
. The keypad will emit 3 rapid beeps if the door chime feature is now enabled and a steady 2-second tone if it is now disabled.
The same function can be performed by pressing and holding the Chime function button for 2 seconds.
>
@>@3URJUDP8VHU&RGHV
The following table identifies available user codes:
Programming User Codes:
LED Keypad:
Press
[
][5]
followed by the Master Code. The Program light will flash. The keypad will turn ON the corresponding zone light to indicate
a user code is programmed. Enter the 2-digit user to be programmed, the zone light will flash. Enter a new 4 or 6-digit user code or press
[
]
to delete the user code. After the user code is programmed or deleted, you may enter another 2-digit user to be programmed or press
[#]
to exit.
LCD Keypad:
Press
[
][5]
followed by the Master Code. The keypad will display the first user (user 01) and include the letter ‘P’ in the bottom, right cor-
ner if the user code is programmed. Scroll to the appropriate user and press the
[
]
key to program the user (or enter the 2-digit user num-
ber). Enter a new 4 or 6-digit user code or press
[
]
to delete the user code. After the user code is programmed or deleted, scroll to another
user or press
[#]
to exit.
Programming Partition Assignment:
Press
[
][5]
followed by the Master Code or Supervisor Code. Press
[98]
followed by the 2-digit user to change to the partition assignment.
The keypad will turn
ON
the corresponding zone light to indicate which partition(s) the user is assigned to. For example, if zone light 1 is
ON
, the user is assigned to partition 1. To change the partition assignment, press the number corresponding to the partition. Once the cor-
rect partitions are assigned to the user, press
[#]
to exit. To change the partition assignment for another user, press
[98]
followed by the 2-
digit user number. When finished, press
[#]
to exit.
Programming User Attributes:
Press
[
][5]
followed by the Master Code or Supervisor Code. Press
[99]
followed by the 2-digit user to change to the user attributes. The
keypad will turn
ON
the corresponding zone light to indicate which attributes are assigned to the user.
Light
[1]
User can enter User Code Programming section with this code
Light
[2]
Duress Reporting Code is sent whenever this code is entered
Light
[3]
User can manually bypass zones
Light
[4]
User can access the Escort5580 module remotely
Light
[5]
For Future Use
Light
[6]
For Future Use
Light
[7]
The panel will squawk the bell output when the user arms/disarms
Light
[8]
One-time use code – Can disarm the system once per day and is reset at midnight.
To change the user attributes, press the number corresponding to the attribute. Once the correct attributes are assigned to the user, press
[#]
to exit. To change the user attributes for another user, press
[99]
followed by the 2-digit user number. When finished, press
[#]
to exit.
Code
Type
Function
[01]-[39], [41]-[95]
General User Codes
arm, disarm
[40]
Master Code
all functions
firealarmresources.com
Summary of Contents for DSC PowerSeries PC1616