Section 5 Programming Descriptions

13

6HFWLRQ>@6\VWHP7LPHV

After entering Section

 [005]

, enter the 2-digit subsection number for the desired partition and program the 

Entry Delay 1

Entry Delay 2

 and 

Exit Delay

 for each active partition on the system. Valid entries are from 

[001]

 to 

[255]

. Enter subsection 

[09]

 to program the 

Bell Cut-Off 

Time

.  Valid entries are from 

[001]

 to 

[255]

 (in minutes).

6HFWLRQ>@,QVWDOOHU&RGH

The default Installer Code is 

[5555]

 or 

[555555]

 if 6-Digit Access Codes is enabled.

6HFWLRQ>@0DVWHU&RGH

The installer does not have access to this section. The master code can be restored to default in section [989] Default Master Code. The 
default Master Code is [1234] or [123456] if 6-Digit Access Codes is enabled.

6HFWLRQ>@0DLQWHQDQFH&RGH

The default Maintenance Code is 

[AAAA]

 (not programmed).  

6HFWLRQ>@WR>@3*02XWSXWV

The PC1616 and PC1832 have two on-board PGM outputs (PGM1 and PGM2).  The PC1864 has four on-board PGM outputs (PGM1 to 
PGM4). The panel has the capacity for up to 14 PGM outputs (8 additional low-current PGM outputs with PC5208 module, 4 additional 
high-current PGM outputs with a PC5204 module).

3*02XWSXW2SWLRQV

[35]

24-Hour Bell/Buzzer:

 Instant alarm when violated, system will activate bell output if armed, keypad buzzer if disarmed

[36]

24-hour Non-Latching Tamper Zone: 

Instant tamper condition when violated. Active in both the armed and disarmed state

[37]

Night Zone:

 Functions like Interior Stay/Away but will remain bypassed if the user presses 

[

,

][1]

 to re-activate Stay/Away zones 

when armed in the Stay mode

[41]

24 Hr. Carbon Monoxide:

 This zone type is used with a hardwired CO detector. This zone definition has a distinct bell cadence in 

the event of an alarm. The cadence of this alarm is 4 cycles of 100ms on/off pulses, followed by a 5-second pause, and then 
repeated. After 4 minutes, the 5-second pause is extended to 60 seconds in duration. The bell is silenced when an access code is 
entered or the bell times out (see your CO detector instruction sheet for more details)

[81]

24 Hr. Carbon Monoxide (Wireless): 

This zone type is used with a wireless CO detector. This zone definition has a distinct bell 

cadence in the event of an alarm. The cadence of this alarm is 4 cycles of 100ms on/off pulses, followed by a 5-second pause, and 
then repeated. After 4 minutes, the 5-second pause is extended to 60 seconds in duration. The bell is silenced when an access code 
is entered or the bell times out

[87]

Delayed 24-Hour Fire (Wireless/Addressable):

 Same as Delayed 24-Hour Fire (Hardwire) but must be used for wireless or 

addressable smoke detectors

[88]

Standard 24-Hour Fire (Wireless/Addressable):

 Same as Standard 24-Hour Fire (Hardwire) but must be used for wireless or 

addressable smoke detectors

Option Description

[00]

For Future Use

[01]

Fire and Burglary:

 Output will activate (steady for burglary, pulsing for fire) if an alarm occurs on the selected partition

[02]

For Future Use

[03]

Sensor Reset:

 Output will normally be active and deactivate for 5 seconds when a 

[

,

][7][2] 

fire reset command is entered or when an 

Auto-Verify Fire alarm is detected

[04]

2-Wire Smoke:

 Configures PGM2 as 2-wire smoke detector input (PGM2 only)

[05]

Armed Status:

 Output will activate when all of the selected partitions are armed

[06]

Ready Status:

 Output will activate when all the selected partitions are in the Ready state (Ready light 

ON

)

[07]

Keypad Buzzer Follow:

 Output will activate and follow the keypad buzzer for the selected partition when the following events occur; 

entry delay, door chime, audible exit delay, automatic arming pre-alert, 24-Hour Supervisory Buzzer zone alarm

[08]

Courtesy Pulse:

 Output will activate during entry/exit delay if the selected partition is armed – will remain active for an additional 2 

minutes after the entry or exit delay expires

[09]

System Trouble:

 Output will activate when any selected trouble condition is present

[10]

Latched System Event (Strobe):

 Output will activate when a selected condition occurs on any selected partition.  Note output can be 

programmed to follow timer

[11]

System Tamper:

 Output will activate when any tamper condition is present

[12]

TLM and Alarm:

 Output will activate if a telephone line trouble is present and then an alarm occurs

[13]

Kissoff:

 Output will activate for 2 seconds when a valid kissoff is received from the central station

[14]

Ground Start:

 Output will activate for 2 seconds when the panel attempts to seize the phone line (additional dial tone search must be 

programmed in the central station phone number – HEX 

[D]

)

[15]

Remote Operation:

 Output can be activated/deactivated via the DLS software

firealarmresources.com

Summary of Contents for DSC PowerSeries PC1616

Page 1: ...PDWLRQ RQ OLPLWDWLRQV UHJDUGLQJ SURGXFW XVH DQG IXQFWLRQ DQG LQIRUPDWLRQ RQ WKH OLPLWDWLRQV DV WR OLDELOLW WKH PDQXIDFWXUHU 7KH HQWLUH PDQXDO VKRXOG EH FDUHIXOO UHDG PC1616 PC1832 PC1864 v4 5 QVWDOODW...

Page 2: ...firealarmresources com...

Page 3: ...XQFWLRQ H V Section 4 Programming 10 RZ WR 3URJUDP 3URJUDPPLQJ 7RJJOH 2SWLRQV 3URJUDPPLQJ HFLPDO DQG H DGHFLPDO DWD RZ WR LW QVWDOOHU 3URJUDPPLQJ 9LHZLQJ 3URJUDPPLQJ 6 3URJUDPPLQJ 6 DWWHU 9ROWDJH LDJQ...

Page 4: ...or falls below 5oC 41oF Smoke detectors should always be installed in USA in accordance with Chapter 11 of NFPA 72 the National Fire Alarm Code 11 5 1 1 Where required by applicable laws codes or sta...

Page 5: ...en using 14Ah battery capacity and AUX current limited to 480mA max Refer to Installation Section 2 10 Battery Recharging time 48h Programmable recharging current Low 400mA High 700mA Low battery trou...

Page 6: ...SPECIFICATIONS Temp Range 0 C 55 C Humidity Max 93 R H Power Supply 16 5VAC 40VA 60Hz Current Draw Panel 110mA nom Aux Output 12VDC 500mA Bell Output 12VDC 700mA User Codes 47 Master Code 71 Master Co...

Page 7: ...location Snap in place 2 Position circuit board mounting holes over standoffs Press firmly on board to snap in place IMPORTANT Minimum 1 4 6 4mm separation must be maintained at all points between BA...

Page 8: ...ce Loop Status Fault 0 shorted wire loop Secure 5600 contact closed Tamper infinite broken wire open Violated 11 200 contact open RQH SDQGHUV Zone expanders add zones in groups of eight to the Alarm s...

Page 9: ...MAX Standby Impedance 1020 Alarm Impedance 570 MAX Alarm Current 89mA MAX 2 wire Smoke Detectors 4 wire Smoke Detectors DUERQ 0RQR LGH HWHFWRU LULQJ RM 1 RM 2 POWER LOOP SUPERVISORY RELAY DSC FSA 210C...

Page 10: ...dules see table on page 2 of this publication it does not include a battery safety margin Battery Charging Current mA 4Ah 7Ah batteries Batt Size 4hr 12Hr 24Hr 36Hr 4Ah 500mA 220mA 7Ah 500mA 480mA 150...

Page 11: ...the system If an alarm occurred while the panel was armed the Memory light and the zones that went into alarm will be flashing LED keypad or the keypad will display Alarm in Memory LCD keypad Press th...

Page 12: ...user user 01 and include the letter P in the bottom right cor ner if the user code is programmed Scroll to the appropriate user and press the key to program the user or enter the 2 digit user num ber...

Page 13: ...H V Keypads have 5 programmable one touch function buttons located in a column down the right side of the keypad These buttons can also be activated by pressing and holding number 1 through 5 respecti...

Page 14: ...Ready light will turn OFF and the Armed light will turn ON For sections that do not require data for every box such as phone numbers press the key to exit the program section after entering all the r...

Page 15: ...6 DWWHU 9ROWDJH LDJQRVWLFV Using DLS software the panel battery voltage can be monitored The battery voltage can be viewed in the panels DLS session window when the panel information is uploaded Any...

Page 16: ...tant alarm and communication when violated 09 24 Hour Supervision Hardwire Instant alarm and communication when violated Will not sound the bell or keypad buzzer 10 24 Hour Supervisory Buzzer Instant...

Page 17: ...cycles of 100ms on off pulses followed by a 5 second pause and then repeated After 4 minutes the 5 second pause is extended to 60 seconds in duration The bell is silenced when an access code is entere...

Page 18: ...ll pulse one second ON one second OFF if an alarm occurs 31 Alternate Communicator Activates when selected system event occurs If active in the armed state it remains active until the system is disarm...

Page 19: ...restored after the system is armed OFF the exit delay will count down as normal 8 ON the bell output will not timeout if a fire alarm occurs The user must turn off the bell by entering a valid user c...

Page 20: ...elay Interior Stay Away Delay Stay Away and Night Zone 5 ON The system logs and communicates a Late To Close event when it auto arms at the programmed time not if auto arming was caused by the No Acti...

Page 21: ...times should be programmed to be longer than entry delay When entry delay ends the bell delay will clear and the siren will activate Any burg type zone will follow transmission delay when the zone al...

Page 22: ...tem is programmed to report the event OFF The system will always report the Test Transmission reporting code at the programmed time 4 ON The system changes the Test Transmission Reporting Cycle Time f...

Page 23: ...Hour and Increment or Month Week Day of Week Hour and Increment 6HFWLRQ 3 0 2XWSXW 7LPHU Program the time in seconds PGM outputs programmed to follow the PGM Output Timer will activate for Valid entr...

Page 24: ...ming The keypads will provide a steady tone warning the user that the system will arm The user can enter a valid access code to abort the arming sequence Valid entries are 000 to 255 6HFWLRQ 3DUWLWLRQ...

Page 25: ...r the system will use the Communicator Format programmed for Phone Number 1 Valid entries are 01 to 13 Refer to the Programming Worksheet for a list of the available Communicator Formats See Appendix...

Page 26: ...em alternates between the First Phone Number and Third Phone Number when attempting to report an event OFF The panel will dial the First Phone Number for the programmed number of attempts then switch...

Page 27: ...ing on the first attempt to dial the central station OFF The system does not dial the Call Waiting Cancel String 5 ON Enables support for the T Link module OFF Disables T Link 6 ON The AC Failure Tran...

Page 28: ...OFF A user code is not required Option Description 1 ON PGM output activates if a Service Required trouble condition is present 2 ON PGM output activates if an AC trouble condition is present 3 ON PG...

Page 29: ...GD 6FKHGXOH Program the dates to be used for Auto disarm holiday schedule Section 691 for Partition 1 Section 692 for Partition 2 etc Each Section has fourteen 6 digit entries two digits for the month...

Page 30: ...OFF Non critical events Test transmission Periodic Test and System Test will not abort the session Events will be communicated after the session is complete Option Description 1 ON The communicator u...

Page 31: ...6HFWLRQ 3DQHO 9HUVLRQ LVSOD HG Only available with LCD5500 or PK5500 keypads The system will display the version of the control panel for example 0410 indicates panel version 4 10 6HFWLRQ QVWDOOHU DO...

Page 32: ...opriate Section followed by the Installer Code followed by the Section number E g 993 Installer Code 993 Section 993 Factory Default Alternate Communicator Section 995 Factory Default Escort5580 Modul...

Page 33: ...HQDQFH ODUP 5HSRUWLQJ RGHV 3URJUDPPLQJ 2SWLRQ 3DJH 0DLQWHQDQFH 5HVWRUDO 5HSRUWLQJ RGHV 0LVFHOODQHRXV 0DLQWHQDQFH 5HSRUWLQJ RGHV 7HVW 7UDQVPLVVLRQ 5HSRUWLQJ RGHV RPPXQLFDWRU RUPDW 2SWLRQV ODUP 5HVWRUH...

Page 34: ...m 15 Global Stay Arming 26 Time and Date 05 9 No Entry Arm 16 0 Quick Exit 27 Select Partition 3 06 4 Chime On Off 17 1 Reactivate Stay Away Zones 28 Select Partition 4 07 6 4 System Test 18 Global Aw...

Page 35: ...__I 14 00 I _ ____I _ ____I 30 00 I _ ____I _ ____I 46 00 I _ ____I _ ____I 62 00 I _ ____I _ ____I 15 00 I _ ____I _ ____I 31 00 I _ ____I _ ____I 47 00 I _ ____I _ ____I 63 00 I _ ____I _ ____I 16 0...

Page 36: ...ult Default 01 I_______I_______I PGM 3 main panel PC5208 01 I_______I_______I PGM 7 PC5208 01 I_______I_______I PGM 4 main panel PC5208 01 I_______I_______I PGM 8 PC5208 01 I_______I_______I PGM 5 PC5...

Page 37: ...ell Squawk On Entry Delay 5 J Bell Squawk On Trouble J No Bell Squawk On Trouble 6 J Audible Exit with Urgency J Silent Exit Delay 7 J Exit Delay Termination Enabled J Exit Delay Termination Disabled...

Page 38: ...bled 7 J For Future Use J 8 J Squawk on Away Key Arming Disarming Only J Squawk on all Arming Disarming Opt Def ON OFF 1 J Test Transmission Exception Enabled J Test Transmission Exception Disabled 2...

Page 39: ...Zones Cancel Arming Disabled 8 J Audible Exit Delay for Stay Arming J Stay Arming Silent Opt Def ON OFF 1 J Fire Key Beeps Only J Fire Key Beeps and Sounds Bell 2 J 200 Baud Open Close Identifier Tog...

Page 40: ...r Delay Y Y N Y N Y N N 26 24hr Non alarm N N N N Y N N N 29 Auto Verified Fire Y N N N N N N N 30 Fire Supervisory N N N N N N N N 31 Day Zone Y Y N Y Y Y Y N 32 Instant Stay Away Y Y N Y N N N N 35...

Page 41: ...__I 118 18 I________I I________ I________ I________ I________ I________ I________ I________I I________I 119 19 I________I I________ I________ I________ I________ I________ I________ I________I I______...

Page 42: ...________I I________I 151 51 I________I I________ I________ I________ I________ I________ I________ I________I I________I 152 52 I________I I________ I________ I________ I________ I________ I________ I...

Page 43: ...alid Entries 000 023 Def 001 Decrement _______ _______ _______ Valid Entries 001 002 6XQGD 0RQGD 7XHVGD HGQHVGD 7KXUVGD ULGD 6DWXUGD I_______I_______I I_______I_______I I_______I_______I I_______I____...

Page 44: ...J Partition 8 is enabled J Disabled Partition 1 Zone Assignment Partition 2 Zone Assignment Partition 3 Zone Assignment Partition 4 Zone Assignment 202 1 8 JJJJJJJJ 210 1 8 JJJJJJJJ 218 1 8 JJJJJJJJ...

Page 45: ...____I I_______I_______I I_______I_______I Zone 41 Zone 42 Zone 43 Zone 44 Zone 45 Zone 46 Zone 47 Zone 48 I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I___...

Page 46: ...____I_______I Cross Zone Police Code Alarm I_______I_______I Burglary Not Verified I_______I_______I Alarm Cancelled 3ULRULW ODUP DQG 5HVWRUDO I_______I_______I Keypad Fire Alarm I_______I_______I Key...

Page 47: ...eporting Codes Access Codes 1 32 6HFWLRQ Code 1 Code 2 Code 3 Code 4 Code 5 Code 6 Code 7 Code 8 I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I____...

Page 48: ...estoral I_______I_______I For Future Use I_______I_______I Cold Start 0LVFHOODQHRXV 0DLQWHQDQFH 5HSRUWLQJ RGHV 7HVW 7UDQVPLVVLRQ 5HSRUWLQJ RGHV I_______I_______I Telephone Number 1 FTC Restore I______...

Page 49: ...4 I________I I________I I________I I________I I________I I________I 363 5 I________I I________I I________I I________I I________I I________I 364 6 I________I I________I I________I I________I I________I...

Page 50: ...7UDQVPLVVLRQ 7LPH RI D Default 3HULRGLF 6 7LPH RI D Default LUVW RPPXQLFDWRU 2SWLRQV 6HFRQG RPPXQLFDWRU 2SWLRQV 9999 I_______I_______I_______I_______I Valid entries are 0000 2359 9999 to disable 9999...

Page 51: ...sabled 4 J Call Waiting Cancel Enabled J Call Waiting Cancel Disabled 5 J T Link Interface Enabled J T Link Interface Disabled 6 J AC Failure Transmission Delay is in Hours J AC Failure Transmission D...

Page 52: ...24 Hr Silent Input PGM2 only 24 24 Hr Audible Input PGM2 only 25 Delayed Burglary Fire Output 26 Battery Test Output 28 Holdup Output 30 Partition Status Alarm Memory Output 33 Bell Status and Progra...

Page 53: ...________ I________ I________ I________I 513 13 I________I I________ I________ I________ I________ I________ I________ I________I 514 14 I________I I________ I________ I________ I________ I________ I__...

Page 54: ...I I_______I_______I I_______I_______I I_______I_______I I_______I_______I 605 608 Opening Disarming Reporting Codes Access Codes 33 95 6HFWLRQ Code 33 Code 34 Code 35 Code 36 Code 37 Code 38 Code 39 C...

Page 55: ...____I_____II_____I_____II_____I_____I I____I_____II_____I_____II_____I_____I I____I_____II_____I_____II_____I_____II____I_____II_____I_____II_____I_____I ROLGD ROLGD ROLGD ROLGD ROLGD ROLGD ROLGD I___...

Page 56: ...UDPPLQJ Refer to the T Link Installation Manual for programming locations and instructions Opt Def ON OFF 1 J 50 Hz AC J 60 Hz AC 2 J Time Base Internal Crystal J Time Base AC Line 3 J AC DC Arming In...

Page 57: ...HVW HIDXOW 0DVWHU RGH QVWDOOHU RGH QVWDOOHU RFNRXW QDEOH QVWDOOHU RGH QVWDOOHU RFNRXW LVDEOH QVWDOOHU RGH 5HVWRUH OWHUQDWH RPPXQLFDWRU WR HIDXOW 3URJUDPPLQJ QVWDOOHU RGH 5HVWRUH VFRUW WR HIDXOW 3URJUD...

Page 58: ...RQG RQH DODUP GRHV QRW RFFXU EHIRUH FURVV RQH WLPHU H SLUHV 5 ODUP DQFHOOHG YDOLG DFFHVV FRGH LV HQWHUHG GXULQJ FRPPXQLFDWLRQV FDQFHOOHG ZLQGRZ 5 H ODUP 5HVW H SDG ILUH DODUP DODUP DQG UHVWRUH UHS FRG...

Page 59: ...WDPSHUV UHVWRUDOV 2 RSHQLQJV FORVLQJV 0 5 PLVFHOODQHRXV DODUPV UHVWRUDOV 7 WHVW WUDQVPLVVLRQV XX XVHU QXPEHU XVHU RQH QXPEHU 8VH WKH DLO WR FORVH HYHQW FRGH WR UHSRUW FORVLQJ RU DFWLYLW GHOLQTXHQF QVX...

Page 60: ...the display Press the key to view the additional information LED Keypads LCD Fixed Message Keypads Press 2 to view a trouble condition The trouble light will flash Refer to the Trouble Summary chart...

Page 61: ...Printer connected to PC5400 offline Verify printer operation out of paper paper jam etc T Link Network Fault present T Link Receiver Trouble present T Link Interface Trouble present Refer to the asso...

Page 62: ...ta tion Panel transmits data multiple times without receiving a handshake Verify that the account number and reporting codes are cor rectly programmed NOTE Contact ID and Pulse formats Program a HEX A...

Page 63: ...ent Test Section 904 Violate then restore the tamper If no test result then replace wireless device An open circuit is present on one or more zones with double end of line resistors enabled Remove the...

Page 64: ...tions options 2SWLRQ Q Q Q Q Q Q Q Q HOD HOD QVWDQW QWHULRU QWHULRU 6WD ZD HOD HG 6WD ZD HOD HG RXU LUH 5HIHU WR 6HFWLRQ IRU RQH GHILQLWLRQ GHWDLOV 6WDQGDUG RXU LUH 2SWLRQ 2SW 2SW 1 ORRSV 21 2 6 2 2 2...

Page 65: ...V GLVDEOHG HVFULSWLRQ 3KRQH 3KRQH 6HFWLRQV 6HW DOO 5HSRUWLQJ RGHV WR DXWRPDWLF ODUP 5HVWRUH FDOO GLUHFWLRQV HQDEOHG 21 2 7DPSHU 5HVWRUH DOO GLUHFWLRQV GLVDEOHG 2 2 2SHQLQJ ORVLQJ DOO GLUHFWLRQV GLVDEO...

Page 66: ...3KRQH RQHV ODUP 5HVWRUDO 5HSRUWLQJ RGHV 6HFWLRQ LVDEOHG 0LVFHOODQHRXV 0DLQWHQDQFH 5HSRUWLQJ RGHV 6HFWLRQ 1R FKDQJH WR GHIDXOW YDOXHV LVDEOHG 2SWLRQ 3URJUDPPLQJ 6HFWLRQ 6 RQQHFWLRQ DOO EDFN VHWWLQJ 2SW...

Page 67: ...ust be four digits If the digit 0 is in the account number substitute the HEX digit A for the 0 All reporting codes must be two digits If the digit 0 is in the reporting code substitute the HEX digit...

Page 68: ...ccessfully a fail ure to communicate trouble will only be generated once the max imum number of attempts has been reached NOTE Do not use the digit C in a reporting code when using Pager Format In mos...

Page 69: ...he following events 0 Talk Listen Audio Event any event type 1 New Event Alarm Tamper Trouble etc 2 Event Restore Alarm Restore Low Battery Restore etc An option exists in Section 381 Option 5 ON that...

Page 70: ...V RU GXVW R 127 LQVWDOO WKLV HTXLSPHQW QHDU ZDWHU H J EDWKWXE ZDVK ERZO NLWFKHQ ODXQGU VLQN ZHW EDVHPHQW RU QHDU D VZLPPLQJ SRRO R 127 LQVWDOO WKLV HTXLSPHQW DQG LWV DFFHVVRULHV LQ DUHDV ZKHUH WKHUH L...

Page 71: ...as reliable as possible the system may fail to function as intended due to the failure of a component Inadequate Testing Most problems that would prevent an alarm system from operating as intended ca...

Page 72: ...g this limitation You may not make any changes or modifications to the Software without the written permission of an officer of DSC You may not remove any proprietary notices marks or labels from the...

Reviews: